TS-709-10H Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The TS-709-10H is a thermal circuit breaker manufactured by SCHURTER Inc., rated for 10A at 250V AC and 50V DC with push-to-reset panel mount actuation. This component is classified as obsolete, making equivalent and substitute parts necessary for ongoing system maintenance and new design implementations. The part carries CSA C22.2 and UL1077 approvals and is ROHS3 compliant.

Substiute Parts

TS-709-10H
SCHURTER Inc.In Stock: 965TS-709-10H Datasheet
TS-709-10H
Current Part
4404.0022
SCHURTER Inc.In Stock: 11854404.0022 Datasheet
4404.0022
Similar
TS-709-10
SCHURTER Inc.In Stock: 914TS-709-10 Datasheet
TS-709-10
Parametric Equivalent
1140-F111-P1M1-10A
1140-F111-P1M1-10A
Parametric Equivalent
1140-F114-P1M1-10A
1140-F114-P1M1-10A
Parametric Equivalent
1140-G111-P1M1-10A
E-T-AIn Stock: 10021140-G111-P1M1-10A Datasheet
1140-G111-P1M1-10A
Parametric Equivalent
1140-G151-P7M1-10A
E-T-AIn Stock: 11831140-G151-P7M1-10A Datasheet
1140-G151-P7M1-10A
Parametric Equivalent
127-F11-P10-H-KF-10A
127-F11-P10-H-KF-10A
Parametric Equivalent
127-P10-H-KF-050022-10A
127-P10-H-KF-050022-10A
Parametric Equivalent
127-P10-H-KF-10A
E-T-AIn Stock: 988127-P10-H-KF-10A Datasheet
127-P10-H-KF-10A
Parametric Equivalent
127-P11-H-KF-10A
E-T-AIn Stock: 788127-P11-H-KF-10A Datasheet
127-P11-H-KF-10A
Parametric Equivalent
1410-G110-P2F1-S01-10A
1410-G110-P2F1-S01-10A
Parametric Equivalent
1410-G111-P2F1-S01-10A
1410-G111-P2F1-S01-10A
Parametric Equivalent
157-K10-KF-10A
E-T-AIn Stock: 1254157-K10-KF-10A Datasheet
157-K10-KF-10A
Parametric Equivalent
2-5000-K10-H-10A
E-T-AIn Stock: 10632-5000-K10-H-10A Datasheet
2-5000-K10-H-10A
Parametric Equivalent
2-5000-P10-A3-H-10A
2-5000-P10-A3-H-10A
Parametric Equivalent
2-5000-P10-H-10A
E-T-AIn Stock: 9852-5000-P10-H-10A Datasheet
2-5000-P10-H-10A
Parametric Equivalent
CTB-B-B-10-B
Carling TechnologiesIn Stock: 1046CTB-B-B-10-B Datasheet
CTB-B-B-10-B
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number TS-709-10H
Manufacturer SCHURTER Inc.
Series TS
Breaker Type Thermal
Current Rating 10A
Voltage Rating - AC 250V
Voltage Rating - DC 50V
Mounting Type Panel Mount
Actuator Type Push to Reset
Number of Poles 1
Product Status Obsolete
Approval Agencies CSA C22.2, UL1077
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the TS-709-10H is determined by the following critical parameters:

  • Current Rating: 10A (exact match required)
  • Voltage Rating - AC: 250V (exact match required)
  • Voltage Rating - DC: 50V (exact match required)
  • Breaker Type: Thermal (exact match required)
  • Mounting Type: Panel Mount (exact match required)
  • Actuator Type: Push to Reset (exact match required)
  • Number of Poles: 1 (exact match required)

All substitute parts listed below meet these electrical and mechanical specifications. Substitute parts are grouped into two categories: parametric equivalents from E-T-A (series 1140 and 127) and one near-equivalent from SCHURTER Inc. (4404.0022) with minor voltage derating.

Parameter Comparison

Part Number Manufacturer Series Current Rating Voltage AC Voltage DC Breaker Type Mounting Actuator Poles Status Approvals
TS-709-10H SCHURTER Inc. TS 10A 250V 50V Thermal Panel Mount Push to Reset 1 Obsolete CSA C22.2, UL1077
TS-709-10 SCHURTER Inc. TS 10A 250V 50V Thermal Panel Mount Push to Reset 1 Obsolete CSA C22.2, UL1077
4404.0022 SCHURTER Inc. T9-311 10A 240V 48V Thermal Panel Mount Push to Reset 1 Active CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077
1140-F111-P1M1-10A E-T-A 1140 10A 250V 50V Thermal Panel Mount Push to Reset 1 Active CSA C22.2 No 235, IEC 60934, UL1077
1140-F114-P1M1-10A E-T-A 1140 10A 250V 50V Thermal Panel Mount Push to Reset 1 Active CSA C22.2 No 235, IEC 60934, UL1077
1140-G111-P1M1-10A E-T-A 1140 10A 250V 50V Thermal Panel Mount Push to Reset 1 Active CSA C22.2 No 235, IEC 60934, UL1077
1140-G151-P7M1-10A E-T-A 1140 10A 250V 50V Thermal Panel Mount Push to Reset 1 Active CSA C22.2 No 235, IEC 60934, UL1077
127-F11-P10-H-KF-10A E-T-A 127 10A 250V 50V Thermal Panel Mount Push to Reset 1 Active CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
127-P10-H-KF-050022-10A E-T-A 127 10A 250V 50V Thermal Panel Mount Push to Reset 1 Active CSA C22.2 No 235, GB 17701, IEC 60934, UL1077
127-P10-H-KF-10A E-T-A 127 10A 250V 50V Thermal Panel Mount Push to Reset 1 Active CSA C22.2 No 235, GB 17701, IEC 60934, UL1077

Engineering Selection Recommendations

For direct replacement of the obsolete TS-709-10H, the parametric equivalent TS-709-10 from SCHURTER Inc. provides identical electrical specifications and maintains the same approval certifications (CSA C22.2, UL1077). This part is also obsolete but shares the same base product number (TS-709).

For active production designs, E-T-A series 1140 and 127 thermal circuit breakers offer full parametric equivalence at 10A, 250V AC, and 50V DC with push-to-reset panel mount configuration. These parts carry expanded regulatory approvals including IEC 60934 and CSA C22.2 No 235, supporting broader international compliance requirements.

The SCHURTER 4404.0022 operates at reduced voltage ratings (240V AC, 48V DC) and is suitable only for applications where the lower voltage specification is acceptable. This part carries active product status and expanded certifications (EN 60934, GB 17701).

Frequently Asked Questions (FAQ)

Q: Can the TS-709-10H be directly replaced with TS-709-10?

A: Yes. Both parts share identical electrical specifications (10A, 250V AC, 50V DC), thermal breaker type, push-to-reset actuation, and panel mount configuration. Both carry CSA C22.2 and UL1077 approvals. The primary difference is packaging (TS-709-10H in individual packaging versus TS-709-10 in bulk).

Q: Are E-T-A series 1140 and 127 parts fully compatible with TS-709-10H?

A: Yes. All E-T-A parts listed (1140-F111-P1M1-10A, 1140-F114-P1M1-10A, 1140-G111-P1M1-10A, 1140-G151-P7M1-10A, 127-F11-P10-H-KF-10A, 127-P10-H-KF-050022-10A, 127-P10-H-KF-10A) meet all critical electrical and mechanical parameters. These parts carry active product status and include IEC 60934 certification in addition to CSA C22.2 and UL1077.

Q: What is the difference between the E-T-A 1140 and 127 series?

A: Both series meet identical electrical specifications for this 10A application. The series designation reflects different product lines within E-T-A's thermal circuit breaker portfolio. Selection between series depends on internal design requirements and part availability.

Q: Can SCHURTER 4404.0022 be used as a substitute?

A: The 4404.0022 operates at 240V AC and 48V DC, which are lower than the TS-709-10H specification of 250V AC and 50V DC. This part is suitable only for applications where the reduced voltage rating is acceptable. All other parameters (10A current, thermal type, push-to-reset, panel mount, single pole) are equivalent.

Q: What certifications should I verify for my application?

A: The TS-709-10H carries CSA C22.2 and UL1077 approvals. E-T-A substitutes expand this to include IEC 60934 and CSA C22.2 No 235. The SCHURTER 4404.0022 adds EN 60934 and GB 17701. Confirm that your application requirements align with the certification scope of your selected part.

Q: Are there packaging differences between substitute parts?

A: Yes. TS-709-10H is supplied in individual packaging, TS-709-10 in bulk, and all E-T-A parts in bulk packaging. Packaging does not affect electrical or mechanical compatibility but may impact procurement and inventory management.

Request Quote (Ships tomorrow)