TS-701-HT-8H Circuit Breaker Thermal 8A 250VAC 50VDC Equivalent & Substitute Parts

Part Overview

The TS-701-HT-8H is a thermal circuit breaker manufactured by SCHURTER Inc., rated for 8A at 250V AC and 50V DC with push-to-reset panel mount actuation. This part is classified as obsolete. Equivalent and substitute parts are necessary to maintain system functionality and ensure continued availability for applications requiring thermal circuit protection with these electrical specifications.

Substiute Parts

TS-701-HT-8H
SCHURTER Inc.In Stock: 822TS-701-HT-8H Datasheet
TS-701-HT-8H
Current Part
4404.0021
SCHURTER Inc.In Stock: 10124404.0021 Datasheet
4404.0021
Similar
TS-701-HT-8K
SCHURTER Inc.In Stock: 1126TS-701-HT-8K Datasheet
TS-701-HT-8K
Parametric Equivalent
1140-G111-P1M1-8A
E-T-AIn Stock: 8701140-G111-P1M1-8A Datasheet
1140-G111-P1M1-8A
Parametric Equivalent
1140-G151-P7M1-8A
E-T-AIn Stock: 7591140-G151-P7M1-8A Datasheet
1140-G151-P7M1-8A
Parametric Equivalent
127-P10-H-KF-050022-8A
127-P10-H-KF-050022-8A
Parametric Equivalent
127-P10-H-KF-8A
E-T-AIn Stock: 1110127-P10-H-KF-8A Datasheet
127-P10-H-KF-8A
Parametric Equivalent
1410-G110-P2F1-S01-8A
1410-G110-P2F1-S01-8A
Parametric Equivalent
1410-G111-P2F1-S01-8A
1410-G111-P2F1-S01-8A
Parametric Equivalent
2-5000-P10-H-8A
E-T-AIn Stock: 10872-5000-P10-H-8A Datasheet
2-5000-P10-H-8A
Parametric Equivalent
CTB-B-B-08
Carling TechnologiesIn Stock: 1160CTB-B-B-08 Datasheet
CTB-B-B-08
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number TS-701-HT-8H
Manufacturer SCHURTER Inc.
Breaker Type Thermal
Current Rating 8A
Voltage Rating - AC 250V
Voltage Rating - DC 50V
Mounting Type Panel Mount
Actuator Type Push to Reset
Number of Poles 1
Product Status Obsolete
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the TS-701-HT-8H is determined by the following critical parameters:

  • Current Rating: 8A (exact match required)
  • Voltage Rating - AC: 250V (exact match required)
  • Voltage Rating - DC: 50V (exact match required)
  • Breaker Type: Thermal (exact match required)
  • Mounting Type: Panel Mount (exact match required)
  • Actuator Type: Push to Reset (exact match required)
  • Number of Poles: 1 (exact match required)

Substitute parts must meet all seven criteria above. Parts are grouped into two categories: parametric equivalents (identical electrical and mechanical specifications) and similar alternatives (minor voltage deviations acceptable for specific applications).

Parameter Comparison

Manufacturer Part Number Manufacturer Current Rating Voltage AC Voltage DC Breaker Type Mounting Type Actuator Type Poles Product Status RoHS Status
TS-701-HT-8H SCHURTER Inc. 8A 250V 50V Thermal Panel Mount Push to Reset 1 Obsolete ROHS3 Compliant
4404.0021 SCHURTER Inc. 8A 240V 48V Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
TS-701-HT-8K SCHURTER Inc. 8A 250V 50V Thermal Panel Mount Push to Reset 1 Obsolete ROHS3 Compliant
1140-G111-P1M1-8A E-T-A 8A 250V 50V Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
1140-G151-P7M1-8A E-T-A 8A 250V 50V Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
127-P10-H-KF-050022-8A E-T-A 8A 250V 50V Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
127-P10-H-KF-8A E-T-A 8A 250V 50V Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
1410-G110-P2F1-S01-8A E-T-A 8A 250V 50V Thermal Panel Mount Push to Reset 1 Active RoHS Compliant
1410-G111-P2F1-S01-385803-8A E-T-A 8A 250V 50V Thermal Panel Mount Push to Reset 1 Active RoHS Compliant
1410-G111-P2F1-S01-8A E-T-A 8A 250V 50V Thermal Panel Mount Push to Reset 1 Active RoHS Compliant
2-5000-P10-H-8A E-T-A 8A 250V 50V Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant

Engineering Selection Recommendations

Parametric Equivalents (Recommended Primary Substitutes)

The following parts are parametric equivalents with identical electrical and mechanical specifications to the TS-701-HT-8H:

  • TS-701-HT-8K (SCHURTER Inc., Obsolete status)
  • 1140-G111-P1M1-8A (E-T-A, Active status)
  • 1140-G151-P7M1-8A (E-T-A, Active status)
  • 127-P10-H-KF-050022-8A (E-T-A, Active status)
  • 127-P10-H-KF-8A (E-T-A, Active status)
  • 1410-G110-P2F1-S01-8A (E-T-A, Active status)
  • 1410-G111-P2F1-S01-385803-8A (E-T-A, Active status)
  • 1410-G111-P2F1-S01-8A (E-T-A, Active status)
  • 2-5000-P10-H-8A (E-T-A, Active status)

All parametric equivalents carry active product status except TS-701-HT-8K. E-T-A manufactured parts hold certifications including CSA C22.2 No 235, IEC 60934, and UL1077. All are ROHS3 compliant or RoHS compliant.

Similar Alternative (Voltage Deviation)

  • 4404.0021 (SCHURTER Inc., Active status): Rated 240V AC / 48V DC. This part deviates from the specified 250V AC / 50V DC ratings and is suitable only for applications where lower voltage ratings are acceptable.

Frequently Asked Questions (FAQ)

Q: Can I use 4404.0021 as a direct replacement for TS-701-HT-8H?

A: No. The 4404.0021 is rated 240V AC / 48V DC, while the TS-701-HT-8H is rated 250V AC / 50V DC. Use 4404.0021 only if your application operates at or below 240V AC and 48V DC.

Q: What is the difference between TS-701-HT-8K and the parametric equivalents from E-T-A?

A: TS-701-HT-8K is electrically and mechanically identical to TS-701-HT-8H but is also obsolete. E-T-A equivalents (1140 series, 127 series, 1410 series, 2-5000 series) provide the same specifications with active product status and broader certification coverage.

Q: Are all parametric equivalents interchangeable?

A: Yes. All parametric equivalents meet the identical electrical specifications (8A, 250V AC, 50V DC) and mechanical requirements (panel mount, push-to-reset, single pole, thermal breaker). Physical form factor and mounting dimensions are consistent across all listed equivalents.

Q: What certifications apply to these circuit breakers?

A: SCHURTER parts carry ROHS3 compliance. E-T-A parts carry ROHS3 or RoHS compliance and hold approvals per CSA C22.2 No 235, IEC 60934, UL1077, and GB 17701 (where applicable).

Q: Does packaging type affect substitution eligibility?

A: No. Packaging (Box, Bulk) does not affect electrical or mechanical compatibility. Select based on procurement requirements and inventory management.

Q: Why is TS-701-HT-8H obsolete while equivalents remain active?

A: TS-701-HT-8H has been discontinued by SCHURTER Inc. Parametric equivalents from E-T-A and the TS-701-HT-8K variant remain in active production, ensuring continued availability for applications requiring 8A thermal circuit protection at 250V AC / 50V DC.