TS-701-HT-8 Circuit Breaker Thermal 8A 250VAC 50VDC Equivalent & Substitute Parts

Part Overview

The TS-701-HT-8 is a thermal circuit breaker manufactured by SCHURTER Inc., rated for 8A at 250V AC and 50V DC with push-to-reset panel mount actuation. This component is classified as obsolete, making equivalent and substitute parts necessary for ongoing system maintenance and new design implementations. The part is ROHS3 compliant and REACH unaffected, meeting current environmental standards.

Substiute Parts

TS-701-HT-8
SCHURTER Inc.In Stock: 979TS-701-HT-8 Datasheet
TS-701-HT-8
Current Part
4404.0021
SCHURTER Inc.In Stock: 10124404.0021 Datasheet
4404.0021
Similar
TS-701-HT-8K
SCHURTER Inc.In Stock: 1126TS-701-HT-8K Datasheet
TS-701-HT-8K
Parametric Equivalent
CLB-083-11ANN-R-A
Carling TechnologiesIn Stock: 987CLB-083-11ANN-R-A Datasheet
CLB-083-11ANN-R-A
Similar
1140-G111-P1M1-8A
E-T-AIn Stock: 8701140-G111-P1M1-8A Datasheet
1140-G111-P1M1-8A
Parametric Equivalent
1140-G151-P7M1-8A
E-T-AIn Stock: 7591140-G151-P7M1-8A Datasheet
1140-G151-P7M1-8A
Parametric Equivalent
127-P10-H-KF-050022-8A
127-P10-H-KF-050022-8A
Parametric Equivalent
127-P10-H-KF-8A
E-T-AIn Stock: 1110127-P10-H-KF-8A Datasheet
127-P10-H-KF-8A
Parametric Equivalent
1410-G110-P2F1-S01-8A
1410-G110-P2F1-S01-8A
Parametric Equivalent
1410-G111-P2F1-S01-8A
1410-G111-P2F1-S01-8A
Parametric Equivalent
2-5000-P10-H-8A
E-T-AIn Stock: 10872-5000-P10-H-8A Datasheet
2-5000-P10-H-8A
Parametric Equivalent
CTB-B-B-08
Carling TechnologiesIn Stock: 1160CTB-B-B-08 Datasheet
CTB-B-B-08
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number TS-701-HT-8
Manufacturer SCHURTER Inc.
Series TS
Breaker Type Thermal
Current Rating 8A
Voltage Rating - AC 250V
Voltage Rating - DC 50V
Mounting Type Panel Mount
Actuator Type Push to Reset
Number of Poles 1
Product Status Obsolete
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the TS-701-HT-8 are classified based on electrical parameter equivalence and mechanical compatibility. The primary substitution criteria are:

Electrical Parameters:

  • Current Rating: 8A (exact match required)
  • Voltage Rating - AC: 250V (exact match required)
  • Voltage Rating - DC: 50V or lower (50V DC is maximum allowable)
  • Breaker Type: Thermal (exact match required)

Mechanical Parameters:

  • Mounting Type: Panel Mount (exact match required)
  • Actuator Type: Push to Reset (exact match required)
  • Number of Poles: 1 (exact match required)

Substitutes are grouped into two categories: parametric equivalents (identical electrical and mechanical specifications) and similar parts (matching core parameters with minor voltage deviations).

Parameter Comparison

Manufacturer Part Number Manufacturer Current Rating (A) Voltage AC (V) Voltage DC (V) Breaker Type Mounting Type Actuator Type Poles Product Status RoHS Status
TS-701-HT-8 SCHURTER Inc. 8 250 50 Thermal Panel Mount Push to Reset 1 Obsolete ROHS3 Compliant
TS-701-HT-8K SCHURTER Inc. 8 250 50 Thermal Panel Mount Push to Reset 1 Obsolete ROHS3 Compliant
4404.0021 SCHURTER Inc. 8 240 48 Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
CLB-083-11ANN-R-A Carling Technologies 8 250 32 Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
1140-G111-P1M1-8A E-T-A 8 250 50 Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
1140-G151-P7M1-8A E-T-A 8 250 50 Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
127-P10-H-KF-050022-8A E-T-A 8 250 50 Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
127-P10-H-KF-8A E-T-A 8 250 50 Thermal Panel Mount Push to Reset 1 Active ROHS3 Compliant
1410-G110-P2F1-S01-8A E-T-A 8 250 50 Thermal Panel Mount Push to Reset 1 Active RoHS Compliant
1410-G111-P2F1-S01-385803-8A E-T-A 8 250 50 Thermal Panel Mount Push to Reset 1 Active RoHS Compliant
1410-G111-P2F1-S01-8A E-T-A 8 250 50 Thermal Panel Mount Push to Reset 1 Active RoHS Compliant

Engineering Selection Recommendations

Parametric Equivalents (Identical Specifications):

The following parts match all electrical and mechanical parameters of the TS-701-HT-8:

  • TS-701-HT-8K (SCHURTER Inc., Obsolete) — Same series variant with identical ratings
  • 1140-G111-P1M1-8A (E-T-A, Active) — Active product with CSA C22.2 No 235, IEC 60934, UL1077 certifications
  • 1140-G151-P7M1-8A (E-T-A, Active) — Active product with CSA C22.2 No 235, IEC 60934, UL1077 certifications
  • 127-P10-H-KF-050022-8A (E-T-A, Active) — Active product with CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 certifications
  • 127-P10-H-KF-8A (E-T-A, Active) — Active product with CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 certifications
  • 1410-G110-P2F1-S01-8A (E-T-A, Active) — Active product with CSA C22.2 No 235, IEC 60934, UL1077 certifications
  • 1410-G111-P2F1-S01-385803-8A (E-T-A, Active) — Active product with CSA C22.2 No 235, IEC 60934, UL1077 certifications
  • 1410-G111-P2F1-S01-8A (E-T-A, Active) — Active product with CSA C22.2 No 235, IEC 60934, UL1077 certifications

For new designs and long-term availability, E-T-A parametric equivalents are preferred due to active product status and established regulatory certifications.

Similar Parts (Voltage Deviations):

  • 4404.0021 (SCHURTER Inc., Active) — 240V AC / 48V DC variant. Suitable where system voltage is 240V AC or lower and DC voltage is 48V or lower
  • CLB-083-11ANN-R-A (Carling Technologies, Active) — 250V AC / 32V DC variant. Suitable where system DC voltage is 32V or lower. Includes CE, cUL, TUV, UL1077, UL1500 certifications

Selection Criteria:

For direct replacement in existing systems rated 250V AC / 50V DC, select from parametric equivalents. For new designs or systems with lower voltage requirements, similar parts provide active product status and extended availability. All listed substitutes maintain thermal breaker operation, 8A current rating, panel mount configuration, and push-to-reset actuation.

Frequently Asked Questions (FAQ)

Q: Can TS-701-HT-8K be used as a direct replacement for TS-701-HT-8?

A: Yes. TS-701-HT-8K is a parametric equivalent with identical electrical ratings (8A, 250V AC, 50V DC), mounting type (panel mount), and actuator type (push to reset). The difference is packaging: TS-701-HT-8 is supplied in standard packaging while TS-701-HT-8K is supplied in bulk packaging.

Q: Is 4404.0021 compatible with TS-701-HT-8?

A: 4404.0021 is compatible only in systems where the AC voltage is 240V or lower and DC voltage is 48V or lower. It shares the same 8A current rating, panel mount configuration, and push-to-reset actuation. However, the voltage ratings are reduced compared to the original part.

Q: What is the difference between E-T-A parametric equivalents?

A: All E-T-A parametric equivalents (1140 series, 127 series, 1410 series) provide identical electrical and mechanical specifications to TS-701-HT-8. Differences exist in series designation and internal design. All are active products with established regulatory approvals. Selection among these variants depends on availability, lead time, and specific application requirements.

Q: Can CLB-083-11ANN-R-A replace TS-701-HT-8 in all applications?

A: CLB-083-11ANN-R-A is suitable only for applications where the DC voltage requirement is 32V or lower. It maintains the 8A current rating, 250V AC rating, panel mount configuration, and push-to-reset actuation. Applications requiring 50V DC operation must use parametric equivalents.

Q: Why are some substitutes listed as obsolete?

A: TS-701-HT-8 and TS-701-HT-8K are both obsolete products. For new designs and systems requiring long-term component availability, active product substitutes from E-T-A (1140, 127, and 1410 series) are recommended.

Q: Are all listed substitutes RoHS compliant?

A: All listed substitutes are RoHS compliant. TS-701-HT-8, TS-701-HT-8K, 4404.0021, CLB-083-11ANN-R-A, and E-T-A 1140 and 127 series parts are ROHS3 compliant. E-T-A 1410 series parts are RoHS compliant. All are REACH unaffected.

Request Quote (Ships tomorrow)