Request Quote
(Ships tomorrow)
TS-701-HT-5 Thermal Circuit Breaker Equivalent & Substitute Parts
Part Overview
The TS-701-HT-5 is a thermal circuit breaker manufactured by SCHURTER Inc., rated for 5A at 250V AC / 50V DC with push-to-reset panel mount actuation. This part is classified as obsolete, making equivalent substitutes necessary for ongoing system maintenance and new designs. The breaker provides single-pole thermal protection suitable for industrial control and power distribution applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | TS-701-HT-5 |
| Manufacturer | SCHURTER Inc. |
| Current Rating | 5A |
| Voltage Rating - AC | 250V |
| Voltage Rating - DC | 50V |
| Breaker Type | Thermal |
| Mounting Type | Panel Mount |
| Actuator Type | Push to Reset |
| Number of Poles | 1 |
| Product Status | Obsolete |
| Approval Agencies | CSA C22.2, UL1077 |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution of the TS-701-HT-5 is determined by strict equivalence across the following critical parameters:
Mandatory Matching Parameters:
- Current Rating: 5A
- Voltage Rating - AC: 250V
- Voltage Rating - DC: 50V
- Breaker Type: Thermal
- Mounting Type: Panel Mount
- Actuator Type: Push to Reset
- Number of Poles: 1
Substitute parts are grouped into two categories:
Category 1 - Parametric Equivalents (Full Specification Match): Parts matching all mandatory parameters with identical electrical and mechanical characteristics. These parts are direct replacements with no derating or operational limitations.
Category 2 - Similar Substitutes (Voltage Variance): Parts matching current rating, breaker type, mounting, and actuation but with reduced DC voltage rating (48V or 32V). These parts are suitable only where system DC voltage does not exceed the substitute part's rating.
Parameter Comparison
| Part Number | Manufacturer | Current (A) | AC Voltage | DC Voltage | Breaker Type | Mounting | Actuator | Poles | Status | Inventory |
|---|---|---|---|---|---|---|---|---|---|---|
| TS-701-HT-5 | SCHURTER Inc. | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Obsolete | 904 Pcs |
| 4404.0025 | SCHURTER Inc. | 5 | 240V | 48V | Thermal | Panel Mount | Push to Reset | 1 | Active | 865 Pcs |
| CLB-053-11ANN-R-A | Carling Technologies | 5 | 250V | 32V | Thermal | Panel Mount | Push to Reset | 1 | Active | 770 Pcs |
| 1140-E211-P1M1-5A | E-T-A | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Active | 1028 Pcs |
| 1140-G111-P1M1-5A | E-T-A | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Active | 1004 Pcs |
| 1140-G151-P7M1-5A | E-T-A | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Active | 2100 Pcs |
| 127-P10-H-KF-050022-5A | E-T-A | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Active | 930 Pcs |
| 127-P10-H-KF-5A | E-T-A | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Active | 668 Pcs |
| 127-P10-H-KF-D91-5A | E-T-A | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Active | 1072 Pcs |
| 1410-G110-P2F1-S01-5A | E-T-A | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Active | 927 Pcs |
| 1410-G111-P2F1-S01-5A | E-T-A | 5 | 250V | 50V | Thermal | Panel Mount | Push to Reset | 1 | Active | 895 Pcs |
Engineering Selection Recommendations
Parametric Equivalents (Full Specification Match):
The following parts provide complete electrical and mechanical equivalence to the TS-701-HT-5:
- 1140-E211-P1M1-5A (E-T-A): Active status, 1028 units in stock. Certifications: CSA C22.2 No 235, IEC 60934, UL1077. ROHS3 compliant.
- 1140-G111-P1M1-5A (E-T-A): Active status, 1004 units in stock. Certifications: CSA C22.2 No 235, IEC 60934, UL1077. ROHS3 compliant.
- 1140-G151-P7M1-5A (E-T-A): Active status, 2100 units in stock. Certifications: CSA C22.2 No 235, IEC 60934, UL1077. ROHS3 compliant. Highest inventory availability.
- 127-P10-H-KF-050022-5A (E-T-A): Active status, 930 units in stock. Certifications: CSA C22.2 No 235, GB 17701, IEC 60934, UL1077. ROHS3 compliant.
- 127-P10-H-KF-5A (E-T-A): Active status, 668 units in stock. Certifications: CSA C22.2 No 235, GB 17701, IEC 60934, UL1077. ROHS3 compliant.
- 127-P10-H-KF-D91-5A (E-T-A): Active status, 1072 units in stock. Certifications: CSA C22.2 No 235, GB 17701, IEC 60934, UL1077. ROHS3 compliant.
- 1410-G110-P2F1-S01-5A (E-T-A): Active status, 927 units in stock. Certifications: CSA C22.2 No 235, IEC 60934, UL1077. RoHS compliant.
- 1410-G111-P2F1-S01-5A (E-T-A): Active status, 895 units in stock. Certifications: CSA C22.2 No 235, IEC 60934, UL1077. RoHS compliant.
Conditional Substitutes (Voltage Variance):
-
4404.0025 (SCHURTER Inc.): Active status, 865 units in stock. Matches 5A current and thermal breaker type. AC voltage reduced to 240V (10V below original), DC voltage reduced to 48V (2V below original). Suitable only where system voltage does not exceed these ratings. Certifications: CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077. ROHS3 compliant.
-
CLB-053-11ANN-R-A (Carling Technologies): Active status, 770 units in stock. Matches 5A current and thermal breaker type. AC voltage matches at 250V, but DC voltage reduced to 32V (18V below original). Suitable only where system DC voltage does not exceed 32V. Certifications: CE, cUL, TUV, UL1077, UL1500. ROHS3 compliant.
Frequently Asked Questions (FAQ)
Q: Can I use 4404.0025 as a direct replacement for TS-701-HT-5?
A: The 4404.0025 is not a direct replacement. While it matches the 5A current rating and thermal breaker type, it has reduced voltage ratings (240V AC / 48V DC versus 250V AC / 50V DC). Use only if your system voltage does not exceed these lower limits.
Q: Which substitute offers the best availability?
A: The 1140-G151-P7M1-5A provides the highest inventory with 2100 units in stock and offers full parametric equivalence with identical electrical specifications and active product status.
Q: Are all E-T-A substitutes interchangeable?
A: The E-T-A parts listed (1140 series, 127 series, and 1410 series) all provide full parametric equivalence to the TS-701-HT-5 with matching 5A / 250V AC / 50V DC ratings. They differ in series designation and internal design but are electrically and mechanically equivalent for panel mount applications.
Q: What certifications should I verify for my application?
A: All listed substitutes carry UL1077 certification. Verify that the specific certifications required by your application (CSA C22.2, IEC 60934, EN 60934, GB 17701, CE, cUL, or TUV) are present on the substitute part selected.
Q: Does the packaging type affect substitution?
A: Packaging (Box or Bulk) does not affect electrical or mechanical compatibility. It affects only handling, storage, and logistics. Select based on your procurement and inventory requirements.
Q: Can I use CLB-053-11ANN-R-A if my system operates at 50V DC?
A: No. The CLB-053-11ANN-R-A is rated for 32V DC maximum. Using it in a 50V DC system exceeds its voltage rating and creates a safety hazard. Use only parametric equivalents or verify that your system voltage does not exceed the substitute part's rating.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts