TS-701-HT-12-K Thermal Circuit Breaker Equivalent & Substitute Parts

Part Overview

The TS-701-HT-12-K is a single-pole thermal circuit breaker manufactured by SCHURTER Inc., rated for 12A at 250V AC and 50V DC with push-to-reset panel mount actuation. This part is classified as obsolete, making equivalent substitutes necessary for ongoing applications and new designs. Substitute parts must maintain identical electrical ratings and mechanical mounting characteristics to ensure direct compatibility in existing installations.

Substiute Parts

TS-701-HT-12-K
SCHURTER Inc.In Stock: 1105TS-701-HT-12-K Datasheet
TS-701-HT-12-K
Current Part
4404.0023
SCHURTER Inc.In Stock: 15914404.0023 Datasheet
4404.0023
Similar
TS-701-HT-12H
SCHURTER Inc.In Stock: 1033TS-701-HT-12H Datasheet
TS-701-HT-12H
Parametric Equivalent
1140-F111-P1M1-12A
1140-F111-P1M1-12A
Parametric Equivalent
1140-G111-P1M1-12A
1140-G111-P1M1-12A
Parametric Equivalent
1140-G151-P7M1-12A
1140-G151-P7M1-12A
Parametric Equivalent
127-P10-H-KF-12A
E-T-AIn Stock: 842127-P10-H-KF-12A Datasheet
127-P10-H-KF-12A
Parametric Equivalent
2-5000-P10-H-12A
E-T-AIn Stock: 9712-5000-P10-H-12A Datasheet
2-5000-P10-H-12A
Parametric Equivalent
CTB-B-B-12
Carling TechnologiesIn Stock: 1391CTB-B-B-12 Datasheet
CTB-B-B-12
Parametric Equivalent

Key Parameters

Parameter Value
Current Rating 12A
Voltage Rating - AC 250V
Voltage Rating - DC 50V
Breaker Type Thermal
Mounting Type Panel Mount
Actuator Type Push to Reset
Number of Poles 1
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility is determined by strict equivalence across the following parameters:

  • Current Rating: 12A (exact match required)
  • Voltage Rating - AC: 250V (exact match required)
  • Voltage Rating - DC: 50V (exact match required)
  • Breaker Type: Thermal (exact match required)
  • Mounting Type: Panel Mount (exact match required)
  • Actuator Type: Push to Reset (exact match required)
  • Number of Poles: 1 (exact match required)

All substitute parts listed below meet these criteria. Parts are grouped by manufacturer and product status to facilitate selection based on availability and compliance requirements.

Parameter Comparison

Manufacturer Part Number Manufacturer Current Rating Voltage AC Voltage DC Breaker Type Mounting Type Actuator Type Poles Product Status Inventory
TS-701-HT-12-K SCHURTER Inc. 12A 250V 50V Thermal Panel Mount Push to Reset 1 Obsolete 1041 Pcs
TS-701-HT-12H SCHURTER Inc. 12A 250V 50V Thermal Panel Mount Push to Reset 1 Obsolete 992 Pcs
4404.0023 SCHURTER Inc. 12A 240V 48V Thermal Panel Mount Push to Reset 1 Active 1491 Pcs
1140-F111-P1M1-12A E-T-A 12A 250V 50V Thermal Panel Mount Push to Reset 1 Active 642 Pcs
1140-G111-P1M1-12A E-T-A 12A 250V 50V Thermal Panel Mount Push to Reset 1 Active 823 Pcs
1140-G151-P7M1-12A E-T-A 12A 250V 50V Thermal Panel Mount Push to Reset 1 Active 678 Pcs
127-P10-H-KF-12A E-T-A 12A 250V 50V Thermal Panel Mount Push to Reset 1 Active 797 Pcs
2-5000-P10-H-12A E-T-A 12A 250V 50V Thermal Panel Mount Push to Reset 1 Active 919 Pcs
CTB-B-B-12 Carling Technologies 12A 250V 50V Thermal Panel Mount Push to Reset 1 Active 1312 Pcs

Engineering Selection Recommendations

Parametric Equivalents (Exact Electrical Match):

The following parts are parametric equivalents with identical electrical and mechanical specifications to TS-701-HT-12-K:

  • TS-701-HT-12H (SCHURTER Inc., Obsolete)
  • 1140-F111-P1M1-12A (E-T-A, Active)
  • 1140-G111-P1M1-12A (E-T-A, Active)
  • 1140-G151-P7M1-12A (E-T-A, Active)
  • 127-P10-H-KF-12A (E-T-A, Active)
  • 2-5000-P10-H-12A (E-T-A, Active)
  • CTB-B-B-12 (Carling Technologies, Active)

All parametric equivalents carry ROHS3 compliance and are certified to IEC 60934 and UL1077 standards. E-T-A and Carling Technologies parts are currently in active production status, ensuring long-term availability.

Near-Equivalent (Voltage Variance):

  • 4404.0023 (SCHURTER Inc., Active) operates at 240V AC and 48V DC, representing a minor voltage reduction from the original specification. This part is suitable only where the lower voltage ratings are acceptable for the application.

Frequently Asked Questions (FAQ)

Q: Can I use 4404.0023 as a direct substitute for TS-701-HT-12-K?

A: No. The 4404.0023 has voltage ratings of 240V AC and 48V DC, compared to the TS-701-HT-12-K specification of 250V AC and 50V DC. Use only if your application operates within the lower voltage envelope.

Q: Which substitute parts are recommended for new designs?

A: Select from active-status parts: 1140-F111-P1M1-12A, 1140-G111-P1M1-12A, 1140-G151-P7M1-12A, 127-P10-H-KF-12A, 2-5000-P10-H-12A, or CTB-B-B-12. All meet identical electrical specifications and carry current manufacturing support.

Q: Are all substitute parts panel-mount compatible with existing installations?

A: Yes. All listed substitutes share identical mounting type (panel mount) and actuator type (push to reset), ensuring mechanical compatibility with existing panel cutouts and control circuits.

Q: What certifications apply to substitute parts?

A: E-T-A parts carry CSA C22.2 No 235, IEC 60934, and UL1077 certifications. Carling Technologies CTB-B-B-12 carries CE, cUL, UL1077, and VDE certifications. All are ROHS3 compliant.

Q: Does packaging type affect substitution eligibility?

A: No. Packaging (bulk or box) does not affect electrical or mechanical compatibility. Select based on procurement quantity requirements and inventory availability.

Request Quote (Ships tomorrow)