TS-701-HT-12H Thermal Circuit Breaker - Equivalent & Substitute Parts

Part Overview

The TS-701-HT-12H is a thermal circuit breaker manufactured by SCHURTER Inc., rated for 12A at 250V AC and 50V DC with push-to-reset panel mount actuation. This component is classified as obsolete, though 992 units remain in stock as new original inventory. Due to its obsolete status, identifying equivalent and substitute parts is essential for system maintenance, design updates, and long-term supply chain continuity. Substitute parts listed below maintain identical electrical ratings and mechanical mounting specifications, ensuring direct functional replacement capability.

Substiute Parts

TS-701-HT-12H
SCHURTER Inc.In Stock: 1033TS-701-HT-12H Datasheet
TS-701-HT-12H
Current Part
4404.0023
SCHURTER Inc.In Stock: 15914404.0023 Datasheet
4404.0023
Similar
TS-701-HT-12-K
SCHURTER Inc.In Stock: 1105TS-701-HT-12-K Datasheet
TS-701-HT-12-K
Parametric Equivalent
1140-F111-P1M1-12A
1140-F111-P1M1-12A
Parametric Equivalent
1140-G111-P1M1-12A
1140-G111-P1M1-12A
Parametric Equivalent
1140-G151-P7M1-12A
1140-G151-P7M1-12A
Parametric Equivalent
127-P10-H-KF-12A
E-T-AIn Stock: 842127-P10-H-KF-12A Datasheet
127-P10-H-KF-12A
Parametric Equivalent
2-5000-P10-H-12A
E-T-AIn Stock: 9712-5000-P10-H-12A Datasheet
2-5000-P10-H-12A
Parametric Equivalent
CTB-B-B-12
Carling TechnologiesIn Stock: 1391CTB-B-B-12 Datasheet
CTB-B-B-12
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number TS-701-HT-12H
Manufacturer SCHURTER Inc.
Series TS
Breaker Type Thermal
Current Rating 12A
Voltage Rating - AC 250V
Voltage Rating - DC 50V
Actuator Type Push to Reset
Mounting Type Panel Mount
Number of Poles 1
Product Status Obsolete
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitute parts for the TS-701-HT-12H are qualified based on strict electrical and mechanical parameter matching:

Critical Matching Parameters:

  • Current Rating: 12A (exact match required)
  • Voltage Rating - AC: 250V (exact match required)
  • Voltage Rating - DC: 50V (exact match required)
  • Breaker Type: Thermal (exact match required)
  • Actuator Type: Push to Reset (exact match required)
  • Mounting Type: Panel Mount (exact match required)
  • Number of Poles: 1 (exact match required)

All substitute parts listed below satisfy these criteria. Substitutes are grouped into two categories: parametric equivalents from SCHURTER Inc. (same manufacturer, same electrical specifications) and parametric equivalents from alternative manufacturers (E-T-A, Carling Technologies) that maintain identical electrical and mechanical characteristics.

Parameter Comparison

Manufacturer Part Number Manufacturer Current Rating (A) Voltage AC (V) Voltage DC (V) Breaker Type Actuator Type Mounting Type Poles Product Status RoHS Status
TS-701-HT-12H SCHURTER Inc. 12 250 50 Thermal Push to Reset Panel Mount 1 Obsolete ROHS3 Compliant
TS-701-HT-12-K SCHURTER Inc. 12 250 50 Thermal Push to Reset Panel Mount 1 Obsolete ROHS3 Compliant
4404.0023 SCHURTER Inc. 12 240 48 Thermal Push to Reset Panel Mount 1 Active ROHS3 Compliant
1140-F111-P1M1-12A E-T-A 12 250 50 Thermal Push to Reset Panel Mount 1 Active ROHS3 Compliant
1140-G111-P1M1-12A E-T-A 12 250 50 Thermal Push to Reset Panel Mount 1 Active ROHS3 Compliant
1140-G151-P7M1-12A E-T-A 12 250 50 Thermal Push to Reset Panel Mount 1 Active ROHS3 Compliant
127-P10-H-KF-12A E-T-A 12 250 50 Thermal Push to Reset Panel Mount 1 Active ROHS3 Compliant
2-5000-P10-H-12A E-T-A 12 250 50 Thermal Push to Reset Panel Mount 1 Active ROHS3 Compliant
CTB-B-B-12 Carling Technologies 12 250 50 Thermal Push to Reset Panel Mount 1 Active ROHS3 Compliant

Engineering Selection Recommendations

SCHURTER Inc. Parametric Equivalent (TS-701-HT-12-K): TS-701-HT-12-K is a direct parametric equivalent from the same manufacturer with identical electrical specifications (12A, 250V AC, 50V DC). Both parts share the TS series designation and obsolete product status. This option provides continuity with the original design intent and manufacturer support. Inventory availability is 1,041 units.

Active Status Alternatives: For new designs or systems requiring active product support, the following parts are recommended based on product status and compliance certifications:

  • E-T-A 1140 Series (1140-F111-P1M1-12A, 1140-G111-P1M1-12A, 1140-G151-P7M1-12A): All three variants maintain identical electrical ratings and are classified as active products. These parts carry CSA C22.2 No 235, IEC 60934, and UL1077 certifications. Inventory ranges from 642 to 823 units.

  • E-T-A 127 Series (127-P10-H-KF-12A): Active product with identical electrical specifications. Certifications include CSA C22.2 No 235, GB 17701, IEC 60934, and UL1077. Inventory: 797 units.

  • E-T-A 2-5000 Series (2-5000-P10-H-12A): Active product with identical electrical specifications. Certifications include CSA C22.2 No 235, GB 17701, IEC 60934, and UL1077. Inventory: 919 units.

  • Carling Technologies CTB Series (CTB-B-B-12): Active product with identical electrical specifications. Certifications include CE, cUL, UL1077, and VDE. Moisture sensitivity level is 1 (Unlimited). Inventory: 1,312 units.

SCHURTER Inc. Voltage Variant (4404.0023): This part differs in voltage ratings (240V AC, 48V DC versus 250V AC, 50V DC) and is classified as active. This option is suitable only for applications with lower voltage requirements and should not be used as a direct substitute for the TS-701-HT-12H without circuit verification.

Frequently Asked Questions (FAQ)

Q: Can TS-701-HT-12-K be used as a direct replacement for TS-701-HT-12H? A: Yes. Both parts are manufactured by SCHURTER Inc., share identical electrical ratings (12A, 250V AC, 50V DC), and have matching mechanical specifications (panel mount, push-to-reset, single pole). The only difference is the part number suffix, which indicates a design variant within the same product family.

Q: What is the difference between the E-T-A 1140 series variants (1140-F111-P1M1-12A, 1140-G111-P1M1-12A, 1140-G151-P7M1-12A)? A: All three variants maintain identical electrical and mechanical specifications for the TS-701-HT-12H application. The alphanumeric designations (F111, G111, G151) represent internal design variations within the E-T-A 1140 series. Selection among these variants should be based on availability and internal design documentation from E-T-A.

Q: Is the SCHURTER 4404.0023 a suitable substitute? A: The 4404.0023 has different voltage ratings (240V AC, 48V DC) compared to the TS-701-HT-12H (250V AC, 50V DC). This part is not a direct substitute and should only be used if the application circuit operates at the lower voltage specifications. Verify circuit requirements before selection.

Q: What certifications apply to substitute parts? A: E-T-A parts carry CSA C22.2 No 235, IEC 60934, and UL1077 certifications (with some variants including GB 17701). Carling Technologies CTB-B-B-12 carries CE, cUL, UL1077, and VDE certifications. All substitute parts are ROHS3 compliant and REACH unaffected.

Q: Are there packaging differences among substitute parts? A: Yes. The TS-701-HT-12H is supplied in bulk packaging. The SCHURTER 4404.0023 is supplied in box packaging. All other substitutes use bulk packaging. Verify packaging requirements for procurement and inventory management.

Q: Which substitute part has the highest inventory availability? A: Carling Technologies CTB-B-B-12 has the highest inventory with 1,312 units in stock. SCHURTER TS-701-HT-12-K has 1,041 units, and E-T-A 2-5000-P10-H-12A has 919 units.

Q: Should I prioritize active or obsolete product status when selecting a substitute? A: For new designs or long-term applications, active products are recommended to ensure ongoing manufacturer support and supply continuity. The TS-701-HT-12H and TS-701-HT-12-K are both obsolete; however, multiple active alternatives with identical specifications are available from E-T-A and Carling Technologies.

Request Quote (Ships tomorrow)