Equivalent & Substitute Parts for TML 30115

Part Overview

The Traco Power TML 30115 is an AC/DC converter in the "Enclosed AC DC Converters" category, offering single output of 15V at 2A (30W total output power). It accepts a wide input range of 90 ~ 264 VAC or 100 ~ 370 VDC. The device features through-hole mounting and is housed in a 7-DIP Module, 5 Leads package. The TML 30115 is currently obsolete; therefore, identification of equivalent or substitute models is necessary for both new designs and maintenance of existing systems requiring its electrical and mechanical characteristics.

Substiute Parts

TML 30115
Traco PowerIn Stock: 927TML 30115 Datasheet
TML 30115
Current Part
TMG 30115
Traco PowerIn Stock: 862TMG 30115 Datasheet
TMG 30115
Similar
TMM 24115
Traco PowerIn Stock: 790TMM 24115 Datasheet
TMM 24115
Similar
TMP 30115
Traco PowerIn Stock: 945TMP 30115 Datasheet
TMP 30115
Similar
TPP 30-115-D
Traco PowerIn Stock: 1146TPP 30-115-D Datasheet
TPP 30-115-D
Similar

Key Parameters

Parameter Value
Manufacturer Traco Power
Manufacturer Part Number TML 30115
Category AC/DC CONVERTER
Type Enclosed
Number of Outputs 1
Voltage - Input 90 ~ 264 VAC, 100 ~ 370 VDC
Voltage - Output 1 15V
Current - Output (Max) 2A
Power (Watts) 30 W
Mounting Type Through Hole
Package / Case 7-DIP Module, 5 Leads
Size / Dimension 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm)
Approval Agency CE, cURus
RoHS Status ROHS3 Compliant
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8504.40.9510
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution is determined strictly by matching the following electrical and mechanical parameters: input voltage range, output voltage, output current, output power, number of outputs, type (Enclosed), mounting type (Through Hole), package/case, regulatory compliance, and approval agency certification. All listed substitutes provide single output (15V), support similar or wider input ranges, and offer equivalent output power. Regulatory and compliance parameters, such as RoHS status and agency approval, are included per categorization requirements.

Parameter Comparison

Manufacturer Part Number Series Product Status Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Mounting Type Package / Case Size / Dimension Approval Agency RoHS Status REACH Status ECCN HTSUS
TML 30115 TML Obsolete Enclosed 1 90 ~ 264 VAC,
100 ~ 370 VDC
15V 2A 30 W ITE (Commercial) Through Hole 7-DIP Module, 5 Leads 3.50" L x 2.50" W x 0.98" H CE, cURus ROHS3 Compliant REACH Unaffected EAR99 8504.40.9510
TMG 30115 TMG (30W) Active Enclosed 1 90 ~ 305 VAC,
120 ~ 370 VDC
15V 2A 30 W ITE (Commercial) Through Hole 5-DIP Module, 4 Leads 2.52" L x 1.77" W x 0.93" H CE, cURus ROHS3 Compliant REACH Unaffected EAR99 8504.40.9510
TMM 24115 TMM 24 (24W) Active Enclosed 1 85 ~ 264 VAC,
120 ~ 370 VDC
15V 1.6A 24 W Industrial, ITE (Commercial), Medical Through Hole 6-DIP Module, 4 Leads 2.91" L x 2.13" W x 0.77" H CB, CE, cULus, cURus ROHS3 Compliant REACH Unaffected EAR99 8504.40.9510
TMP 30115 TMP (30W) Active Enclosed 1 85 ~ 264 VAC,
120 ~ 370 VDC
15V 2A 30 W ITE (Commercial) Through Hole 7-DIP Module, 5 Leads 3.50" L x 2.50" W x 0.85" H CB, CE, cULus, cURus ROHS3 Compliant REACH Unaffected EAR99 8504.40.9510
TPP 30-115-D TPP 30-D (30W) Active Enclosed 1 85 ~ 264 VAC,
120 ~ 370 VDC
15V 2A 30 W Household Appliances, ITE (Commercial), Medical Through Hole 5-DIP Module 2.89" L x 1.50" W x 1.01" H CB, CE, cURus ROHS3 Compliant REACH Unaffected EAR99 8504.40.9510

Engineering Selection Recommendations

Select substitute parts for TML 30115 strictly based on product status (active), RoHS and REACH compliance, and approval agency listings. Only substitute models with the indicated certifications (CB, CE, cURus, cULus as specified per part) and compliant environmental status should be chosen. Pin configuration, package style, and dimension fields are provided for direct comparison and should be matched as required by system design constraints.

Frequently Asked Questions (FAQ)

Q: What are the primary substitution criteria for TML 30115?
A: Key substitution criteria include matching input voltage range, output voltage and current, output power, number of outputs, mounting type, package form factor, and regulatory approval.

Q: Are mechanical mounting and package compatibility required?
A: Mechanical compatibility is established by comparing mounting type and package/case dimensions. Ensure system requirements align with substitute models’ specifications.

Q: Are all substitutes RoHS and REACH compliant?
A: All listed substitutes are ROHS3 Compliant and REACH Unaffected as per provided specifications.

Q: Is agency approval important for substitution?
A: Approval agency listings (CE, cURus, CB, cULus) should match system compliance requirements.

Q: How should output and input ranges be assessed for substitutions?
A: Confirm that substitute parts support equal or wider input voltage and output current ranges than the original part.

Q: Can models with different package dimensions be directly substituted?
A: Direct substitution is possible if system design accepts alternate package dimensions and lead configurations. Review the provided mechanical specifications for compatibility.

Q: Is efficiency a substitution criterion?
A: Efficiency is listed, but substitution focuses on primary operational parameters unless otherwise mandated by the design requirements.

Request Quote (Ships tomorrow)