The Traco Power TML 30115 is an AC/DC converter in the "Enclosed AC DC Converters" category, offering single output of 15V at 2A (30W total output power). It accepts a wide input range of 90 ~ 264 VAC or 100 ~ 370 VDC. The device features through-hole mounting and is housed in a 7-DIP Module, 5 Leads package. The TML 30115 is currently obsolete; therefore, identification of equivalent or substitute models is necessary for both new designs and maintenance of existing systems requiring its electrical and mechanical characteristics.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Traco Power |
| Manufacturer Part Number | TML 30115 |
| Category | AC/DC CONVERTER |
| Type | Enclosed |
| Number of Outputs | 1 |
| Voltage - Input | 90 ~ 264 VAC, 100 ~ 370 VDC |
| Voltage - Output 1 | 15V |
| Current - Output (Max) | 2A |
| Power (Watts) | 30 W |
| Mounting Type | Through Hole |
| Package / Case | 7-DIP Module, 5 Leads |
| Size / Dimension | 3.50" L x 2.50" W x 0.98" H (88.9mm x 63.5mm x 25.0mm) |
| Approval Agency | CE, cURus |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9510 |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution is determined strictly by matching the following electrical and mechanical parameters: input voltage range, output voltage, output current, output power, number of outputs, type (Enclosed), mounting type (Through Hole), package/case, regulatory compliance, and approval agency certification. All listed substitutes provide single output (15V), support similar or wider input ranges, and offer equivalent output power. Regulatory and compliance parameters, such as RoHS status and agency approval, are included per categorization requirements.
Parameter Comparison
| Manufacturer Part Number | Series | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Mounting Type | Package / Case | Size / Dimension | Approval Agency | RoHS Status | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TML 30115 | TML | Obsolete | Enclosed | 1 | 90 ~ 264 VAC, 100 ~ 370 VDC |
15V | 2A | 30 W | ITE (Commercial) | Through Hole | 7-DIP Module, 5 Leads | 3.50" L x 2.50" W x 0.98" H | CE, cURus | ROHS3 Compliant | REACH Unaffected | EAR99 | 8504.40.9510 |
| TMG 30115 | TMG (30W) | Active | Enclosed | 1 | 90 ~ 305 VAC, 120 ~ 370 VDC |
15V | 2A | 30 W | ITE (Commercial) | Through Hole | 5-DIP Module, 4 Leads | 2.52" L x 1.77" W x 0.93" H | CE, cURus | ROHS3 Compliant | REACH Unaffected | EAR99 | 8504.40.9510 |
| TMM 24115 | TMM 24 (24W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC |
15V | 1.6A | 24 W | Industrial, ITE (Commercial), Medical | Through Hole | 6-DIP Module, 4 Leads | 2.91" L x 2.13" W x 0.77" H | CB, CE, cULus, cURus | ROHS3 Compliant | REACH Unaffected | EAR99 | 8504.40.9510 |
| TMP 30115 | TMP (30W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC |
15V | 2A | 30 W | ITE (Commercial) | Through Hole | 7-DIP Module, 5 Leads | 3.50" L x 2.50" W x 0.85" H | CB, CE, cULus, cURus | ROHS3 Compliant | REACH Unaffected | EAR99 | 8504.40.9510 |
| TPP 30-115-D | TPP 30-D (30W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC |
15V | 2A | 30 W | Household Appliances, ITE (Commercial), Medical | Through Hole | 5-DIP Module | 2.89" L x 1.50" W x 1.01" H | CB, CE, cURus | ROHS3 Compliant | REACH Unaffected | EAR99 | 8504.40.9510 |
Engineering Selection Recommendations
Select substitute parts for TML 30115 strictly based on product status (active), RoHS and REACH compliance, and approval agency listings. Only substitute models with the indicated certifications (CB, CE, cURus, cULus as specified per part) and compliant environmental status should be chosen. Pin configuration, package style, and dimension fields are provided for direct comparison and should be matched as required by system design constraints.
Frequently Asked Questions (FAQ)
Q: What are the primary substitution criteria for TML 30115?
A: Key substitution criteria include matching input voltage range, output voltage and current, output power, number of outputs, mounting type, package form factor, and regulatory approval.
Q: Are mechanical mounting and package compatibility required?
A: Mechanical compatibility is established by comparing mounting type and package/case dimensions. Ensure system requirements align with substitute models’ specifications.
Q: Are all substitutes RoHS and REACH compliant?
A: All listed substitutes are ROHS3 Compliant and REACH Unaffected as per provided specifications.
Q: Is agency approval important for substitution?
A: Approval agency listings (CE, cURus, CB, cULus) should match system compliance requirements.
Q: How should output and input ranges be assessed for substitutions?
A: Confirm that substitute parts support equal or wider input voltage and output current ranges than the original part.
Q: Can models with different package dimensions be directly substituted?
A: Direct substitution is possible if system design accepts alternate package dimensions and lead configurations. Review the provided mechanical specifications for compatibility.
Q: Is efficiency a substitution criterion?
A: Efficiency is listed, but substitution focuses on primary operational parameters unless otherwise mandated by the design requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts