Equivalent & Substitute Parts Reference for Traco Power TML 30105

Part Overview

The Traco Power TML 30105 is an enclosed AC/DC converter, featuring 1 output of 5V at 6A, suitable for ITE (Commercial) applications. The product is currently classified as obsolete, with limited inventory available. As such, identifying equivalent and substitute models with compatible electrical and mechanical characteristics is necessary for ongoing design, repair, and replacement requirements.

Substiute Parts

TML 30105
Traco PowerIn Stock: 729TML 30105 Datasheet
TML 30105
Current Part
TMG 30105
Traco PowerIn Stock: 1050TMG 30105 Datasheet
TMG 30105
Similar
TMM 24105
Traco PowerIn Stock: 954TMM 24105 Datasheet
TMM 24105
Similar
TMP 30105
Traco PowerIn Stock: 834TMP 30105 Datasheet
TMP 30105
Similar
TPP 30-105-D
Traco PowerIn Stock: 7832TPP 30-105-D Datasheet
TPP 30-105-D
Similar

Key Parameters

Manufacturer Part Number Series Product Status Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS
TML 30105 TML Obsolete Enclosed 1 90 ~ 264 VAC, 100 ~ 370 VDC 5V 6A 30 W ITE (Commercial) Universal Input -25°C ~ 60°C (With Derating) 80% Through Hole 7-DIP Module, 5 Leads 3.50" L x 2.50" W x 0.98" H CE, cURus ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510

Substitute Part Grouping Explanation

Substitute models for Traco Power TML 30105 are selected strictly based on matching the following key parameters: input voltage range, output voltage, output current, output power, type (enclosed), number of outputs, mounting type, package/case, application category, operating temperature range, efficiency, regulatory approvals, RoHS and REACH compliance, and moisture sensitivity level. Models listed below share these core electrical and mechanical attributes within the limits specified, as documented per input data.

Parameter Comparison

Manufacturer Part Number Series Product Status Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS
TML 30105 TML Obsolete Enclosed 1 90 ~ 264 VAC, 100 ~ 370 VDC 5V 6A 30 W ITE (Commercial) Universal Input -25°C ~ 60°C (With Derating) 80% Through Hole 7-DIP Module, 5 Leads 3.50" L x 2.50" W x 0.98" H CE, cURus ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510
TMG 30105 TMG (30W) Active Enclosed 1 90 ~ 305 VAC, 120 ~ 370 VDC 5V 5A 25 W ITE (Commercial) Universal Input -40°C ~ 70°C (With Derating) 84% Through Hole 5-DIP Module, 4 Leads 2.52" L x 1.77" W x 0.93" H CE, cURus ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510
TMM 24105 TMM 24 (24W) Active Enclosed 1 85 ~ 264 VAC, 120 ~ 370 VDC 5V 3A 15 W Industrial, ITE (Commercial), Medical Universal Input -40°C ~ 80°C (With Derating) 77% Through Hole 6-DIP Module, 4 Leads 2.91" L x 2.13" W x 0.77" H CB, CE, cULus, cURus ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510
TMP 30105 TMP (30W) Active Enclosed 1 85 ~ 264 VAC, 120 ~ 370 VDC 5V 6A 30 W ITE (Commercial) Universal Input -25°C ~ 70°C (With Derating) 78% Through Hole 7-DIP Module, 5 Leads 3.50" L x 2.50" W x 0.85" H CB, CE, cULus, cURus ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510
TPP 30-105-D TPP 30-D (30W) Active Enclosed 1 85 ~ 264 VAC, 120 ~ 370 VDC 5V 6A 30 W Household Appliances, ITE (Commercial), Medical Adjustable Output, Universal Input -40°C ~ 85°C (With Derating) 87% Through Hole 5-DIP Module 2.89" L x 1.50" W x 1.01" H CB, CE, cURus ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9510

Engineering Selection Recommendations

All listed substitute parts for Traco Power TML 30105 are active and comply with ROHS3 and REACH standards. Each model is covered by relevant approval agencies (CE, cURus, CB, cULus), supporting use in similar application environments. Product selection can be based on matching regulatory compliance, standardized mounting type, and package/case form as specified.

Frequently Asked Questions (FAQ)

Q1: What parameters are most critical for selecting an equivalent AC/DC converter to TML 30105?
A1: Critical parameters include input voltage range, output voltage and current, output power, type (enclosed), number of outputs, mounting type (through hole), package/case dimensions, regulatory approvals, RoHS and REACH compliance, and operating temperature range.

Q2: Are substitute units compatible with the same mounting and installation methods?
A2: All substitutes use through hole mounting. Package and case dimensions differ; check pin layout and mechanical fit for direct replacement.

Q3: Is regulatory agency approval consistent across substitutes?
A3: Substitute models meet CE and cURus requirements. Some units provide additional approvals (CB, cULus), expanding potential application scope.

Q4: Are all substitute models compliant with ROHS and REACH standards?
A4: Yes, every listed substitute is ROHS3 compliant and REACH unaffected.

Q5: How does the output power or current rating of substitutes compare to the original TML 30105?
A5: Substitute power ranges from 15 W (TMM 24105) to 30 W (TMP 30105, TPP 30-105-D). Output current varies; TMG 30105 offers 5A, others offer up to 6A. Select according to required output load.

Q6: Will substitute units fit identically in all installations?
A6: Package/case sizes and lead configurations differ; mechanical compatibility must be referenced to the stated dimensions and form factor.

Request Quote (Ships tomorrow)