The TLK1201RCP is a full-duplex IEEE 802.3 transceiver manufactured by Texas Instruments, housed in a 64-HVQFP surface mount package. This component functions as a 1/1 transceiver for network interface applications requiring full-duplex communication compliance with IEEE 802.3 standards. The TLK1201RCP is classified as obsolete, making identification of suitable substitute components essential for ongoing system support, maintenance, and new design implementations where legacy compatibility is required.

Substiute Parts

TLK1201RCP
Texas InstrumentsIn Stock: 1600TLK1201RCP Datasheet
TLK1201RCP
Current Part
TLK2201BRCP
Texas InstrumentsIn Stock: 2155TLK2201BRCP Datasheet
TLK2201BRCP
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number TLK1201RCP
Manufacturer Texas Instruments
Category Interface
Type Transceiver
Protocol IEEE 802.3
Number of Drivers/Receivers 1/1
Duplex Full
Voltage - Supply 2.3V ~ 2.7V
Operating Temperature -40°C ~ 85°C
Mounting Type Surface Mount
Package / Case 64-PowerVFQFP
Supplier Device Package 64-HVQFP (10x10)
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 3 (168 Hours)
REACH Status REACH Unaffected
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the TLK1201RCP is determined by strict alignment of the following critical parameters:

  • Protocol compliance: IEEE 802.3 full-duplex transceiver functionality
  • Electrical specifications: Supply voltage range 2.3V ~ 2.7V
  • Physical form factor: 64-HVQFP (10x10) surface mount package
  • Driver/receiver configuration: 1/1 transceiver architecture
  • Environmental compliance: RoHS3 and REACH certification status
  • Moisture sensitivity: MSL 3 classification

The TLK2201BRCP qualifies as a manufacturer-recommended substitute based on identical protocol, package, electrical supply range, and compliance certifications. Differences in operating temperature range and product status do not preclude substitution when system thermal requirements fall within the substitute's specified operating window.

Parameter Comparison

Parameter TLK1201RCP TLK2201BRCP Compatibility
Manufacturer Texas Instruments Texas Instruments Identical
Category Interface Interface Identical
Type Transceiver Transceiver Identical
Protocol IEEE 802.3 IEEE 802.3 Identical
Number of Drivers/Receivers 1/1 1/1 Identical
Duplex Full Full Identical
Voltage - Supply 2.3V ~ 2.7V 2.3V ~ 2.7V Identical
Operating Temperature -40°C ~ 85°C 0°C ~ 70°C Substitute range is narrower
Mounting Type Surface Mount Surface Mount Identical
Package / Case 64-PowerVFQFP 64-PowerVFQFP Identical
Supplier Device Package 64-HVQFP (10x10) 64-HVQFP (10x10) Identical
RoHS Status ROHS3 Compliant ROHS3 Compliant Identical
Moisture Sensitivity Level (MSL) 3 (168 Hours) 3 (168 Hours) Identical
REACH Status REACH Unaffected REACH Unaffected Identical
Product Status Obsolete Last Time Buy Substitute available for limited time

Engineering Selection Recommendations

The TLK2201BRCP is the manufacturer-recommended substitute for the obsolete TLK1201RCP. Both components maintain identical electrical specifications, package geometry, and compliance certifications. The TLK2201BRCP carries Last Time Buy status, indicating limited availability; procurement should be prioritized if this component is selected for system redesign or legacy support.

The operating temperature range difference (TLK2201BRCP: 0°C ~ 70°C versus TLK1201RCP: -40°C ~ 85°C) requires evaluation against actual system thermal requirements. Applications operating below 0°C or above 70°C cannot use the TLK2201BRCP as a direct substitute. For such applications, alternative solutions must be sourced.

Both components satisfy RoHS3 and REACH compliance requirements, supporting use in regulated markets and applications with environmental compliance mandates.

Frequently Asked Questions (FAQ)

Q: Can the TLK2201BRCP directly replace the TLK1201RCP in existing designs?

A: Yes, provided the system operating temperature remains within 0°C to 70°C. The electrical specifications, package footprint, and protocol compliance are identical. PCB layout and signal routing require no modification.

Q: What is the primary difference between these two parts?

A: Operating temperature range. The TLK1201RCP operates from -40°C to 85°C, while the TLK2201BRCP operates from 0°C to 70°C. All other parameters are identical.

Q: Why is the TLK1201RCP classified as obsolete?

A: Obsolete status indicates the manufacturer has discontinued production. The TLK2201BRCP represents the current-generation equivalent, though it carries Last Time Buy status, meaning availability is limited.

Q: Are there any package or pinout differences?

A: No. Both components use the 64-HVQFP (10x10) surface mount package with identical pinout and electrical characteristics.

Q: What does Last Time Buy status mean for the TLK2201BRCP?

A: Last Time Buy indicates the manufacturer will accept orders for a limited period before discontinuing the part. Procurement planning should account for this timeline if this component is selected.

Q: Do both parts meet the same compliance standards?

A: Yes. Both are RoHS3 compliant and REACH unaffected, supporting equivalent regulatory compliance in all markets.