TL100-A2TPV Current Sensor Equivalent & Substitute Parts

Part Overview

The TL100-A2TPV is an active Hall Effect current sensor manufactured by Mornsun America, LLC, designed for bidirectional AC/DC current measurement applications. This closed-loop module features a single pass-through configuration with 100A sensing capability and ratiometric voltage output. The product maintains Active status with 849 units in current inventory stock. Equivalent and substitute parts are identified to support procurement flexibility, design redundancy, and supply chain continuity when the primary part number becomes unavailable or when alternative sourcing is required.

Substiute Parts

TL100-A2TPV
Mornsun America, LLCIn Stock: 933TL100-A2TPV Datasheet
TL100-A2TPV
Current Part
TL100-A2PV
Mornsun America, LLCIn Stock: 789TL100-A2PV Datasheet
TL100-A2PV
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number TL100-A2TPV
Manufacturer Mornsun America, LLC
Series TL1xx-A2TPV
Product Status Active
Sensor Type Hall Effect, Closed Loop
Current Sensing Range 100A
Number of Channels 1
Measurement Type AC/DC Bidirectional
Output Type Ratiometric, Voltage
Sensitivity 6.25mV/A
Frequency Response DC ~ 200kHz
Linearity ±0.1%
Accuracy ±0.5%
Supply Voltage 4.75V ~ 5.25V
Response Time 300ns
Maximum Supply Current 14mA
Operating Temperature Range -40°C ~ 105°C
Mounting Type Through Hole
Package Configuration Module, Single Pass Through
RoHS Compliance ROHS3 Compliant
ECCN Classification EAR99
HTSUS Code 9030.33.3800

Substitute Part Grouping Explanation

Substitution eligibility for the TL100-A2TPV is determined by strict equivalence across all critical electrical and mechanical parameters. The substitute part TL100-A2PV qualifies as a parametric equivalent based on the following criteria:

Critical Substitution Parameters:

  • Identical current sensing range: 100A
  • Identical sensor technology: Hall Effect, Closed Loop
  • Identical measurement capability: AC/DC Bidirectional
  • Identical output configuration: Ratiometric, Voltage
  • Identical sensitivity: 6.25mV/A
  • Identical frequency response: DC ~ 200kHz
  • Identical linearity specification: ±0.1%
  • Identical accuracy specification: ±0.5%
  • Identical supply voltage range: 4.75V ~ 5.25V
  • Identical response time: 300ns
  • Identical maximum supply current: 14mA
  • Identical operating temperature range: -40°C ~ 105°C
  • Identical mounting type: Through Hole
  • Identical package configuration: Module, Single Pass Through
  • Identical RoHS compliance: ROHS3 Compliant
  • Identical regulatory classification: EAR99

Both parts belong to the TL1xx series family and maintain Active product status. The substitution is based on complete parameter alignment with no deviations in electrical performance, thermal characteristics, or mechanical form factor.

Parameter Comparison

Parameter TL100-A2TPV TL100-A2PV Match Status
Manufacturer Mornsun America, LLC Mornsun America, LLC Identical
Series TL1xx-A2TPV TL1xx-A2PV Same Family
Product Status Active Active Identical
Sensor Type Hall Effect, Closed Loop Hall Effect, Closed Loop Identical
Current Sensing 100A 100A Identical
Number of Channels 1 1 Identical
Measurement Type AC/DC Bidirectional AC/DC Bidirectional Identical
Output Type Ratiometric, Voltage Ratiometric, Voltage Identical
Sensitivity 6.25mV/A 6.25mV/A Identical
Frequency Response DC ~ 200kHz DC ~ 200kHz Identical
Linearity ±0.1% ±0.1% Identical
Accuracy ±0.5% ±0.5% Identical
Supply Voltage 4.75V ~ 5.25V 4.75V ~ 5.25V Identical
Response Time 300ns 300ns Identical
Maximum Supply Current 14mA 14mA Identical
Operating Temperature -40°C ~ 105°C -40°C ~ 105°C Identical
Mounting Type Through Hole Through Hole Identical
Package Configuration Module, Single Pass Through Module, Single Pass Through Identical
RoHS Compliance ROHS3 Compliant ROHS3 Compliant Identical
ECCN Classification EAR99 EAR99 Identical
HTSUS Code 9030.33.3800 9030.33.3800 Identical
Current Inventory 849 Pcs 731 Pcs Both In Stock

Engineering Selection Recommendations

Primary Part Selection: TL100-A2TPV

The TL100-A2TPV is the primary specification part with 849 units in current inventory. This part maintains Active product status and full ROHS3 compliance, making it suitable for new designs and production applications without regulatory constraints.

Substitute Part Selection: TL100-A2PV

The TL100-A2PV qualifies as a direct parametric equivalent with identical electrical specifications, thermal performance, and mechanical configuration. This part is also Active status with 731 units available. Selection of the TL100-A2PV is appropriate when:

  • Primary part TL100-A2TPV becomes unavailable from current inventory
  • Supply chain diversification is required across equivalent part numbers
  • Both parts are manufactured by the same supplier (Mornsun America, LLC)
  • Design requirements specify 100A Hall Effect closed-loop current sensing with ratiometric voltage output
  • Operating conditions fall within the -40°C to 105°C temperature range
  • Supply voltage is maintained within 4.75V to 5.25V specification
  • Through-hole mounting configuration is required

Both parts carry identical regulatory classifications (EAR99, HTSUS 9030.33.3800) and compliance certifications, eliminating regulatory substitution barriers.

Frequently Asked Questions (FAQ)

Q: Can TL100-A2PV be used as a direct replacement for TL100-A2TPV in existing designs?

A: Yes. The TL100-A2PV is a parametric equivalent with identical electrical specifications, output characteristics, sensitivity, accuracy, frequency response, and thermal operating range. Both parts feature the same Through Hole mounting configuration and Module, Single Pass Through package. No circuit modifications are required.

Q: Are there any differences in the output signal between these two parts?

A: No. Both parts provide identical ratiometric voltage output with 6.25mV/A sensitivity, ±0.1% linearity, and ±0.5% accuracy. The frequency response (DC ~ 200kHz) and response time (300ns) are identical.

Q: What is the difference between the TL100-A2TPV and TL100-A2PV part numbers?

A: The part numbers differ only in their series designation (TL1xx-A2TPV versus TL1xx-A2PV). All electrical parameters, mechanical specifications, and performance characteristics are identical. Both are manufactured by Mornsun America, LLC and maintain Active product status.

Q: Can these parts be used interchangeably in PCB designs?

A: Yes. Both parts use identical Through Hole mounting and Module, Single Pass Through package configuration. PCB footprints and mounting hole patterns are compatible, allowing direct substitution without layout modifications.

Q: What supply voltage range is required for both parts?

A: Both TL100-A2TPV and TL100-A2PV require a supply voltage of 4.75V to 5.25V. Maximum supply current consumption is 14mA for both parts.

Q: Are both parts RoHS compliant?

A: Yes. Both TL100-A2TPV and TL100-A2PV are ROHS3 Compliant with identical EAR99 export classification and HTSUS code 9030.33.3800.

Q: What is the operating temperature range for these current sensors?

A: Both parts operate across -40°C to 105°C, supporting applications in industrial, automotive, and wide-temperature-range environments.

Q: Can these parts measure both AC and DC current?

A: Yes. Both TL100-A2TPV and TL100-A2PV are bidirectional Hall Effect closed-loop sensors capable of measuring AC/DC current with frequency response from DC to 200kHz.

Q: What is the current sensing range for both parts?

A: Both parts are rated for 100A current sensing with 6.25mV/A sensitivity, providing a single-channel measurement solution.

Request Quote (Ships tomorrow)