Request Quote
(Ships tomorrow)
THL 20-4812WI Equivalent & Substitute Parts Reference
Part Overview
The Traco Power THL 20-4812WI is an isolated DC-DC converter module providing a single 12V output at up to 1.67A, with an 18V to 75V input range and 20W power capability. This model is categorized as Not For New Designs, necessitating the identification of substitute DC-DC converter modules for projects requiring active and ongoing manufacturer support, current compliance, and continued product availability.
Substiute Parts
Key Parameters
| Parameter | THL 20-4812WI |
|---|---|
| Manufacturer | Traco Power |
| Category | |
| Packaging | Tube |
| Description | DC DC CONVERTER 12V 20W |
| Detailed Description | Isolated Module DC DC Converter 1 Output 12V 1.67A 18V - 75V Input |
| Series | THL 20WI (20W) |
| Product Status | Not For New Designs |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 18V |
| Voltage - Input (Max) | 75V |
| Voltage - Output 1 | 12V |
| Current - Output (Max) | 1.67A |
| Power (Watts) | 20 W |
| Voltage - Isolation | 1.5 kV |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, SCP |
| Operating Temperature | -40°C ~ 75°C (With Derating) |
| Efficiency | 89% |
| Mounting Type | Through Hole |
| Package / Case | 6-DIP Module |
| Size / Dimension | 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) |
| Base Product Number | THL 20 |
| RoHS Status | ROHS3 Compliant |
| Inventory | 786 Pcs New Original In Stock |
| Moisture Sensitivity Level (MSL) | Not Applicable |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
| Substitutes | JTK2048S12 |
Substitute Part Grouping Explanation
Substitute DC-DC converter modules for the THL 20-4812WI are selected based strictly on the following allowed parameters: input voltage range, output voltage, maximum output current, power rating, module type, number of outputs, isolation voltage, efficiency, features, package/case, mounting type, and compliance. Only parts meeting or exceeding these specific electrical and mechanical parameters are presented as substitutes.
Parameter Comparison
| Parameter | THL 20-4812WI (Traco Power) | JTK2048S12 (XP Power) |
|---|---|---|
| Description | DC DC CONVERTER 12V 20W | DC DC CONVERTER 12V 20W |
| Detailed Description | Isolated Module DC DC Converter 1 Output 12V 1.67A 18V - 75V Input | Isolated Module DC DC Converter 1 Output 12V 1.67A 18V - 75V Input |
| Series | THL 20WI (20W) | JTK (20W) |
| Product Status | Not For New Designs | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 18V | 18V |
| Voltage - Input (Max) | 75V | 75V |
| Voltage - Output 1 | 12V | 12V |
| Current - Output (Max) | 1.67A | 1.67A |
| Power (Watts) | 20 W | 20 W |
| Voltage - Isolation | 1.5 kV | 1.6 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | Remote On/Off, SCP | Remote On/Off, OCP, OVP, SCP |
| Operating Temperature | -40°C ~ 75°C (With Derating) | -40°C ~ 100°C |
| Efficiency | 89% | 89% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 6-DIP Module | 6-DIP Module |
| Size / Dimension | 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) | 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | Not Applicable | 1 (Unlimited) |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
| Inventory | 786 Pcs New Original In Stock | 1035 Pcs New Original In Stock |
Engineering Selection Recommendations
The THL 20-4812WI has product status Not For New Designs and is not recommended for new projects requiring long-term supply. The JTK2048S12, provided by XP Power, is listed as Active and maintains ROHS3 compliance, with equivalent or improved electrical and mechanical compatibility. Certifications noted for the JTK2048S12 (including standard number 62368-1) meet current compliance requirements, and the module is classified under the same ECCN and HTSUS codes.
Frequently Asked Questions (FAQ)
Q1: What are the primary criteria for selecting a substitute for the THL 20-4812WI?
A1: Substitution is based strictly on matching or exceeding the input voltage range, output voltage, maximum output current, number of outputs, power rating, package, isolation voltage, efficiency, features, and compliance status.
Q2: Are the package sizes and mounting types identical between these modules?
A2: Both the THL 20-4812WI and JTK2048S12 use a 6-DIP Module package and through-hole mounting. Dimensions are within the listed tolerances.
Q3: How does the product status affect component selection?
A3: THL 20-4812WI is Not For New Designs, while JTK2048S12 is Active, aligning with requirements for ongoing supply and future-proofing.
Q4: Are there any differences in compliance or environmental status?
A4: Both converters are ROHS3 compliant and are classified as EAR99 under ECCN and 8504.40.9580 under HTSUS. The JTK2048S12 lists an explicit moisture sensitivity level.
Q5: Are the electrical protections and features compatible?
A5: Both modules provide Remote On/Off and Short-Circuit Protection (SCP). The JTK2048S12 includes additional protections: Over Current Protection (OCP) and Over Voltage Protection (OVP).
Q6: Can the substitute part be directly implemented in existing designs using THL 20-4812WI?
A6: Key electrical and mechanical parameters are matched according to the provided specifications, supporting substitution in layouts and applications designed for the specified module footprint and parameters.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts