The Traco Power TEN 5-4821WI is an Isolated Module DC DC Converter designed for ITE (Commercial) applications, providing dual output voltages of 5V and -5V at 500mA each, with a total output power of 5W. Key features include a wide input voltage range (18V to 75V), 1.5kV isolation, and through hole mounting in a 24-DIP Module package. The product status is "Not For New Designs", indicating that alternative models may be needed for new projects or ongoing procurement. Substitution is necessary when continued supply, design updates, or lifecycle management is required.
Substiute Parts
Key Parameters
| Manufacturer Part Number | TEN 5-4821WI |
|---|---|
| Manufacturer | Traco Power |
| Category | |
| Packaging | Tube |
| Description | DC DC CONVERTER +/-5V 5W |
| Series | TEN 5WI (6W) |
| Product Status | Not For New Designs |
| Type | Isolated Module |
| Number of Outputs | 2 |
| Voltage - Input (Min) | 18V |
| Voltage - Input (Max) | 75V |
| Voltage - Output 1 | 5V |
| Voltage - Output 2 | -5V |
| Current - Output (Max) | 500mA, 500mA |
| Power (Watts) | 5 W |
| Voltage - Isolation | 1.5 kV |
| Applications | ITE (Commercial) |
| Features | SCP |
| Operating Temperature | -40°C ~ 85°C (With Derating) |
| Efficiency | 78% |
| Mounting Type | Through Hole |
| Package / Case | 24-DIP Module, 7 Leads |
| Size / Dimension | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) |
| Supplier Device Package | Module |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | Not Applicable |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute part identification is based strictly on matching the following allowed key parameters: input voltage range (18V–75V), output voltages (5V and -5V), maximum output currents (500mA each), total output power (5W), number of outputs (2), isolation voltage (1.5 kV), mounting type (through hole), package (24-DIP Module, 7 Leads), application category (ITE commercial), RoHS compliance, operating temperature range (-40°C ~ 85°C with derating), and inclusion of SCP feature. Only devices meeting all these criteria can be considered direct substitutes.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Operating Temperature | Mounting Type | Package / Case | RoHS Status | Applications |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TEN 5-4821WI | Traco Power | 18V | 75V | 5V | -5V | 500mA, 500mA | 5 W | 1.5 kV | -40°C ~ 85°C (With Derating) | Through Hole | 24-DIP Module, 7 Leads | ROHS3 Compliant | ITE (Commercial) |
Engineering Selection Recommendations
Because the TEN 5-4821WI is marked as "Not For New Designs," selection for ongoing or future projects must be based on lifecycle status and compliance. Only those substitute parts strictly matching the specified RoHS/REACH compliance, voltage ratings, output configuration, mechanical package, and electrical performance must be considered. No substitute parts are available in the provided input list.
Frequently Asked Questions (FAQ)
Q1: What are the mandatory parameters for finding substitute DC DC converters for TEN 5-4821WI?
A1: The substitute must match the input voltage range (18V–75V), output voltages (5V and -5V), output currents (500mA each), total power (5W), isolation voltage (1.5 kV), output count (2), mounting type (through hole), package (24-DIP Module, 7 Leads), and compliance statuses.
Q2: Can substitutes with similar but not identical parameters be considered?
A2: Only devices matching all listed technical and mechanical parameters can be considered direct substitutes. No deviation is allowed under the provided criteria.
Q3: How does package type affect substitution?
A3: The substitute must use a 24-DIP Module case with 7 leads and through hole mounting. Any difference in package or pin configuration disqualifies a part from direct substitution.
Q4: Why is RoHS or REACH compliance included in the criteria?
A4: Compliance ensures that substitutes meet environmental and safety requirements for global applications. Substitutes must be ROHS3 compliant and REACH unaffected to maintain regulatory status.
Q5: Are any direct substitute parts listed for TEN 5-4821WI?
A5: No direct substitute parts are specified in the provided input list.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts