Equivalent & Substitute Parts for Traco Power TEN 5-4821WI DC DC Converter

Part Overview

The Traco Power TEN 5-4821WI is an Isolated Module DC DC Converter designed for ITE (Commercial) applications, providing dual output voltages of 5V and -5V at 500mA each, with a total output power of 5W. Key features include a wide input voltage range (18V to 75V), 1.5kV isolation, and through hole mounting in a 24-DIP Module package. The product status is "Not For New Designs", indicating that alternative models may be needed for new projects or ongoing procurement. Substitution is necessary when continued supply, design updates, or lifecycle management is required.

Substiute Parts

TEN 5-4821WI
Traco PowerIn Stock: 1096TEN 5-4821WI Datasheet
TEN 5-4821WI
Current Part

Key Parameters

Manufacturer Part NumberTEN 5-4821WI
ManufacturerTraco Power
Category
PackagingTube
DescriptionDC DC CONVERTER +/-5V 5W
SeriesTEN 5WI (6W)
Product StatusNot For New Designs
TypeIsolated Module
Number of Outputs2
Voltage - Input (Min)18V
Voltage - Input (Max)75V
Voltage - Output 15V
Voltage - Output 2-5V
Current - Output (Max)500mA, 500mA
Power (Watts)5 W
Voltage - Isolation1.5 kV
ApplicationsITE (Commercial)
FeaturesSCP
Operating Temperature-40°C ~ 85°C (With Derating)
Efficiency78%
Mounting TypeThrough Hole
Package / Case24-DIP Module, 7 Leads
Size / Dimension1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm)
Supplier Device PackageModule
RoHS StatusROHS3 Compliant
Moisture Sensitivity Level (MSL)Not Applicable
REACH StatusREACH Unaffected
ECCNEAR99
HTSUS8504.40.9580

Substitute Part Grouping Explanation

Substitute part identification is based strictly on matching the following allowed key parameters: input voltage range (18V–75V), output voltages (5V and -5V), maximum output currents (500mA each), total output power (5W), number of outputs (2), isolation voltage (1.5 kV), mounting type (through hole), package (24-DIP Module, 7 Leads), application category (ITE commercial), RoHS compliance, operating temperature range (-40°C ~ 85°C with derating), and inclusion of SCP feature. Only devices meeting all these criteria can be considered direct substitutes.

Parameter Comparison

Manufacturer Part Number Manufacturer Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Voltage - Output 2 Current - Output (Max) Power (Watts) Voltage - Isolation Operating Temperature Mounting Type Package / Case RoHS Status Applications
TEN 5-4821WI Traco Power 18V 75V 5V -5V 500mA, 500mA 5 W 1.5 kV -40°C ~ 85°C (With Derating) Through Hole 24-DIP Module, 7 Leads ROHS3 Compliant ITE (Commercial)

Engineering Selection Recommendations

Because the TEN 5-4821WI is marked as "Not For New Designs," selection for ongoing or future projects must be based on lifecycle status and compliance. Only those substitute parts strictly matching the specified RoHS/REACH compliance, voltage ratings, output configuration, mechanical package, and electrical performance must be considered. No substitute parts are available in the provided input list.

Frequently Asked Questions (FAQ)

Q1: What are the mandatory parameters for finding substitute DC DC converters for TEN 5-4821WI?
A1: The substitute must match the input voltage range (18V–75V), output voltages (5V and -5V), output currents (500mA each), total power (5W), isolation voltage (1.5 kV), output count (2), mounting type (through hole), package (24-DIP Module, 7 Leads), and compliance statuses.

Q2: Can substitutes with similar but not identical parameters be considered?
A2: Only devices matching all listed technical and mechanical parameters can be considered direct substitutes. No deviation is allowed under the provided criteria.

Q3: How does package type affect substitution?
A3: The substitute must use a 24-DIP Module case with 7 leads and through hole mounting. Any difference in package or pin configuration disqualifies a part from direct substitution.

Q4: Why is RoHS or REACH compliance included in the criteria?
A4: Compliance ensures that substitutes meet environmental and safety requirements for global applications. Substitutes must be ROHS3 compliant and REACH unaffected to maintain regulatory status.

Q5: Are any direct substitute parts listed for TEN 5-4821WI?
A5: No direct substitute parts are specified in the provided input list.

Request Quote (Ships tomorrow)