Equivalent & Substitute Parts Reference for TEN 20-4813

Part Overview

The Traco Power TEN 20-4813 is an isolated module DC DC converter with specifications suitable for ITE (Commercial) applications. It delivers a single 15V output at up to 1.34A from a 36V to 75V input, rated for 20W power with 1.5 kV isolation and through-hole mounting in a 6-DIP module case. The product status is "Not For New Designs," which necessitates the identification of direct alternatives for sustained production, maintenance, or design migration purposes.

Substiute Parts

TEN 20-4813
Traco PowerIn Stock: 657TEN 20-4813 Datasheet
TEN 20-4813
Current Part
JCK2048S15
XP PowerIn Stock: 12365JCK2048S15 Datasheet
JCK2048S15
Direct

Key Parameters

Manufacturer Part Number Manufacturer Description Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Product Status
TEN 20-4813 Traco Power DC DC CONVERTER 15V 20W 1 36V 75V 15V 1.34A 20W 1.5 kV ITE (Commercial) -40°C ~ 85°C (With Derating) 89% Through Hole 6-DIP Module 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) ROHS3 Compliant Not For New Designs

Substitute Part Grouping Explanation

Substitution is based on strict equivalency of the following key electrical and mechanical parameters: input voltage range (36V–75V), output voltage (15V), output current (≥1.33A), power rating (20W), isolation voltage (≥1.5 kV), mounting type (through-hole), package/case (6-DIP Module), application suitability (ITE Commercial), efficiency, operating temperature, and RoHS compliance. Only components that match or exceed these parameters are listed as substitutes.

Parameter Comparison

Manufacturer Part Number Manufacturer Description Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Product Status
TEN 20-4813 Traco Power DC DC CONVERTER 15V 20W 1 36V 75V 15V 1.34A 20W 1.5 kV ITE (Commercial) -40°C ~ 85°C (With Derating) 89% Through Hole 6-DIP Module 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) ROHS3 Compliant Not For New Designs
JCK2048S15 XP Power DC DC CONVERTER 15V 20W 1 36V 75V 15V 1.33A 20W 1.6 kV ITE (Commercial) -40°C ~ 100°C 91% Through Hole 6-DIP Module 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) ROHS3 Compliant Active

Engineering Selection Recommendations

The TEN 20-4813 has the status "Not For New Designs," indicating that ongoing or new applications require an alternative for supply continuity and compliance. The XP Power JCK2048S15 offers ROHS3 compliance, matching mechanical package specifications and all required electrical parameters. The product status of JCK2048S15 is "Active," supporting its suitability for new design and replacement needs within regulatory constraints.

Frequently Asked Questions (FAQ)

Q1: What parameters are critical when selecting a substitute for TEN 20-4813?
A1: The critical parameters are input voltage range, output voltage and current, total power rating, isolation voltage, mounting type, package/case, efficiency, operating temperature, and relevant compliance certifications.

Q2: Is the XP Power JCK2048S15 mechanically compatible with the Traco Power TEN 20-4813?
A2: Both parts use a 6-DIP Module package with identical dimensions and through-hole mounting, ensuring direct mechanical compatibility.

Q3: Are the regulatory and environmental compliance statuses equivalent?
A3: Both TEN 20-4813 and JCK2048S15 are ROHS3 Compliant, matching mandated environmental requirements.

Q4: How do the electrical performance characteristics compare?
A4: Input voltage range, output voltage, and power are equivalent. JCK2048S15 has a marginally lower output current (1.33A vs 1.34A) and a higher isolation voltage (1.6 kV vs 1.5 kV), meeting or exceeding substitution criteria.

Q5: What is the impact of product status on component selection?
A5: Since TEN 20-4813 is "Not For New Designs," transitioning to the "Active" JCK2048S15 is necessary to maintain ongoing production and support new projects.

Request Quote (Ships tomorrow)