TEN 15-2421 Equivalent & Substitute Parts Reference

Part Overview

The Traco Power TEN 15-2421 is a DC DC converter categorized as an isolated module with two outputs of +5V and -5V at a maximum output current of 1.5A per rail, accepting a DC input voltage range from 18V to 36V and delivering up to 15W output power. The product features a 1.6 kV isolation voltage, overcurrent, overvoltage, and short circuit protection, with an operating temperature range from -40°C to 85°C (with derating). The mounting type is through hole, in a 5-DIP module package with dimensions 2.00" × 1.00" × 0.40" (50.8mm × 25.4mm × 10.2mm). The TEN 15-2421 is classified as "Not For New Designs," thus prompting the need to identify suitable equivalent or substitute DC DC converter models with matching electrical and mechanical characteristics.

Substiute Parts

TEN 15-2421
Traco PowerIn Stock: 940TEN 15-2421 Datasheet
TEN 15-2421
Current Part
JCK1524D05
XP PowerIn Stock: 12345JCK1524D05 Datasheet
JCK1524D05
Direct
JTH1524D05
XP PowerIn Stock: 12164JTH1524D05 Datasheet
JTH1524D05
Direct

Key Parameters

Manufacturer Part Number Manufacturer Description Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Voltage - Output 2 Current - Output (Max) Power (Watts) Voltage - Isolation Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status
TEN 15-2421 Traco Power DC DC CONVERTER +/-5V 15W TEN 15 (15W) Not For New Designs Isolated Module 2 18V 36V 5V -5V 1.5A, 1.5A 15 W 1.6 kV OCP, OVP, SCP -40°C ~ 85°C (With Derating) 84% Through Hole 5-DIP Module 2.00" × 1.00" × 0.40" (50.8mm × 25.4mm × 10.2mm) ROHS3 Compliant

Substitute Part Grouping Explanation

The selection of substitute parts for the TEN 15-2421 is based strictly on the matching of key parameters critical for functional and mechanical compatibility. These parameters include: number of outputs, input voltage range, output voltages and currents, total output power, isolation voltage, module features, efficiency, operating temperature range, mounting type, package/case, size/dimension, and RoHS compliance. Only parts with these parameters as provided are presented as equivalents or substitutes.

Parameter Comparison

Manufacturer Part Number Manufacturer Description Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Voltage - Output 2 Current - Output (Max) Power (Watts) Voltage - Isolation Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status
TEN 15-2421 Traco Power DC DC CONVERTER +/-5V 15W TEN 15 (15W) Not For New Designs Isolated Module 2 18V 36V 5V -5V 1.5A, 1.5A 15 W 1.6 kV OCP, OVP, SCP -40°C ~ 85°C (With Derating) 84% Through Hole 5-DIP Module 2.00" × 1.00" × 0.40" ROHS3 Compliant
JCK1524D05 XP Power DC DC CONVERTER +/-5V 15W JCK (15W) Active Isolated Module 2 18V 36V 5V -5V 1.5A, 1.5A 15 W 1.5 kV OCP, SCP, UVLO -40°C ~ 100°C 85% Through Hole 5-DIP Module 2.00" × 1.00" × 0.40" ROHS3 Compliant
JTH1524D05 XP Power DC DC CONVERTER +/-5V 15W JTH (15W) Active Isolated Module 2 9V 36V 5V -5V 1.5A, 1.5A 15 W 1.5 kV OCP, OVP, SCP, UVLO -40°C ~ 100°C 83% Through Hole 6-DIP Module 2.00" × 1.00" × 0.40" ROHS3 Compliant

Engineering Selection Recommendations

The TEN 15-2421 is categorized as "Not For New Designs." Substitute models JCK1524D05 and JTH1524D05 are listed as active and are ROHS3 compliant. All parts in this comparison maintain through hole mounting, specified package/case, and matching size/dimensions. For continuity with environmental and regulatory requirements, only parts designated with equivalent or higher RoHS compliance are listed.

Frequently Asked Questions (FAQ)

Q1: What are the critical electrical parameters for substituting the TEN 15-2421 DC DC converter?
A1: Key parameters are input voltage range, output voltages and currents, number of outputs, total power, isolation voltage, features, and efficiency. All substitutes listed adhere strictly to these parameters as provided.

Q2: Are the substitute parts mechanically compatible with TEN 15-2421?
A2: Substitute parts JCK1524D05 and JTH1524D05 have through hole mounting and similar or identical size and package type, supporting direct mechanical interchange or minor PCB adjustments.

Q3: Do the substitute parts comply with RoHS requirements?
A3: All parts presented, including TEN 15-2421, JCK1524D05, and JTH1524D05, are ROHS3 compliant as specified.

Q4: Are differences in isolation voltage and features significant for substitution?
A4: Allowed substitutes match or are very close in isolation voltage and provide a subset or superset of protection features specified in the main part data.

Q5: Can substitute parts be used in the same application environment as the original part?
A5: Provided thermal range, environmental rating, and application categories (ITE, Commercial) are matched as per input parameters. No deviation is presented in the comparison data.

Q6: Are there differences in part status between main and substitute parts?
A6: The TEN 15-2421 is "Not For New Designs"; JCK1524D05 and JTH1524D05 are both listed as "Active." Substitute selection based on product status is appropriate as per provided parameters.