Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference: TEN 10-1211
Part Overview
TEN 10-1211 from Traco Power is an isolated DC-DC converter module delivering 5V at 2A output from a 9V to 18V input, with a power rating of 10W and 1.5 kV isolation. The module features overcurrent protection (OCP), overvoltage protection (OVP), and short circuit protection (SCP). It is RoHS3 compliant and designed for ITE (Commercial) applications. The product status is "Not For New Designs," creating the need for identification of compatible, currently active substitute models with matching electrical, mechanical, and regulatory characteristics.
Substiute Parts
Key Parameters
| Parameter | TEN 10-1211 |
|---|---|
| Manufacturer | Traco Power |
| Series | TEN 10 (10W) |
| Product Status | Not For New Designs |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 9V |
| Voltage - Input (Max) | 18V |
| Voltage - Output 1 | 5V |
| Current - Output (Max) | 2A |
| Power (Watts) | 10 W |
| Voltage - Isolation | 1.5 kV |
| Applications | ITE (Commercial) |
| Features | OCP, OVP, SCP |
| Operating Temperature | -40°C ~ 85°C (With Derating) |
| Efficiency | 77% |
| Mounting Type | Through Hole |
| Package / Case | 5-DIP Module, 4 Leads |
| Size / Dimension | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution is limited to DC-DC converter modules with strict equivalence in electrical input and output parameters, isolation voltage, form factor, operating temperature range, compliance status, and functional features. The key parameters defining substitutability are: input voltage range (9V–18V), output voltage (5V), output current (2A), power (10W), isolation (1.5 kV), operating temperature, protection features, mounting, package dimensions, and RoHS status.
Parameter Comparison
| Parameter | TEN 10-1211 (Traco Power) | JCH1012S05 (XP Power) |
|---|---|---|
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 9V | 9V |
| Voltage - Input (Max) | 18V | 18V |
| Voltage - Output 1 | 5V | 5V |
| Current - Output (Max) | 2A | 2A |
| Power (Watts) | 10 W | 10 W |
| Voltage - Isolation | 1.5 kV | 1.5 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | OCP, OVP, SCP | OCP, SCP |
| Operating Temperature | -40°C ~ 85°C (With Derating) | -40°C ~ 100°C |
| Efficiency | 77% | 82% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 5-DIP Module, 4 Leads | 5-DIP Module |
| Size / Dimension | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
Engineering Selection Recommendations
Selection between TEN 10-1211 and JCH1012S05 is supported by compliance with ROHS3 requirements and both are suitable for ITE (Commercial) applications. TEN 10-1211 is listed as "Not For New Designs," whereas JCH1012S05 is active. Both devices satisfy the same isolation voltage, output specification, mounting style, and mechanical package dimensions.
Frequently Asked Questions (FAQ)
Q1: What defines a compatible substitute for the TEN 10-1211 in DC-DC converter modules?
A1: Compatibility is determined by matching input voltage range, output voltage and current, power rating, isolation voltage, protection features, package dimensions, mounting type, and RoHS compliance status.
Q2: Are there mechanical differences between TEN 10-1211 and JCH1012S05?
A2: Both parts share equivalent size, through-hole mounting, and a 5-DIP module package format based on provided data.
Q3: Are the features and protection mechanisms identical between the two models?
A3: The main part includes OCP, OVP, and SCP, while the substitute lists OCP and SCP. Only provided features are considered.
Q4: Does the operating temperature range affect substitutability?
A4: Both models operate from -40°C with upper limits of 85°C (TEN 10-1211) and 100°C (JCH1012S05). These ranges conform to robust industrial standards as specified.
Q5: Is there a difference in product lifecycle status?
A5: TEN 10-1211 is "Not For New Designs"; JCH1012S05 is marked as active, supporting ongoing production use according to provided status information.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts