T18SP6LP W/30 Equivalent & Substitute Parts

Part Overview

The T18SP6LP W/30 is a retroreflective, polarized optical sensor manufactured by Banner Engineering Corporation, designed for industrial sensing applications requiring a 2-meter detection range. This sensor operates across a 10V to 30V DC supply with PNP output configuration supporting both Dark-ON and Light-ON selectable modes. The unit features a 9-meter cable connection and meets NEMA 6P, IEC IP67, and IEC IP69 ingress protection standards.

The T18SP6LP W/30 is classified as obsolete. Identifying equivalent substitute parts is necessary to maintain system functionality and ensure continued availability for replacement, repair, and new installations where this sensor specification is required.

Substiute Parts

T18SP6LP W/30
Banner Engineering CorporationIn Stock: 1111T18SP6LP W/30 Datasheet
T18SP6LP W/30
Current Part
T18-2VPLP-9M
Banner Engineering CorporationIn Stock: 1096T18-2VPLP-9M Datasheet
T18-2VPLP-9M
Similar

Key Parameters

Parameter Value
Manufacturer Banner Engineering Corporation
Series T18
Category Optical Sensors
Sensing Method Retroreflective, Polarized
Sensing Distance 78.740" (2m)
Voltage Supply 10V ~ 30V DC
Output Configuration PNP - Dark-ON/Light-ON - Selectable
Light Source Red (680nm)
Cable Length 354.33" (9m)
Connection Method Cable
Ingress Protection NEMA 6P, IEC IP67, IEC IP69
Operating Temperature -40°C ~ 70°C
RoHS Status RoHS Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the T18SP6LP W/30 is determined by the following critical parameters that must remain consistent across equivalent parts:

Core Compatibility Parameters:

  • Sensing method: Retroreflective, Polarized
  • Voltage supply range: 10V ~ 30V DC
  • Output configuration: PNP with Dark-ON/Light-ON selectable modes
  • Light source: Red wavelength (680nm or Red LED)
  • Connection method: Cable
  • Cable length: 354.33" (9m)
  • Ingress protection: NEMA 6P, IEC IP67, IEC IP69 minimum
  • Operating temperature range: -40°C ~ 70°C
  • RoHS compliance: Required

Allowable Variation Parameters:

  • Sensing distance: May vary within the retroreflective sensor product line
  • Response time: May vary within acceptable industrial sensor specifications
  • Series designation: May differ within Banner Engineering Corporation T18 product family
  • Product status: Active status preferred for ongoing availability

The T18-2VPLP-9M qualifies as a substitute part based on alignment with all core compatibility parameters and active product status.

Parameter Comparison

Parameter T18SP6LP W/30 (Main Part) T18-2VPLP-9M (Substitute)
Manufacturer Banner Engineering Corporation Banner Engineering Corporation
Category Optical Sensors Optical Sensors
Sensing Method Retroreflective, Polarized Retroreflective, Polarized
Sensing Distance 78.740" (2m) 236.220" (6m)
Voltage Supply 10V ~ 30V DC 10V ~ 30V DC
Response Time 3ms 1.5ms, 750µs
Output Configuration PNP - Dark-ON/Light-ON - Selectable PNP - Dark-ON/Light-ON - Selectable
Light Source Red (680nm) Red LED
Connection Method Cable Cable
Ingress Protection NEMA 6P, IEC IP67, IEC IP69 NEMA 6P, IEC IP67, IEC IP68, IEC IP69
Cable Length 354.33" (9m) 354.33" (9m)
Operating Temperature -40°C ~ 70°C -40°C ~ 70°C
RoHS Status RoHS Compliant RoHS Compliant
Product Status Obsolete Active

Engineering Selection Recommendations

The T18-2VPLP-9M is the designated substitute for the obsolete T18SP6LP W/30. This substitution is supported by the following engineering factors:

Compliance and Regulatory Alignment: Both parts maintain RoHS compliance and REACH unaffected status, ensuring regulatory continuity in applications subject to environmental and hazardous substance restrictions.

Functional Equivalence: The substitute part maintains identical voltage supply range (10V ~ 30V DC), output configuration (PNP with Dark-ON/Light-ON selectability), connection method (9-meter cable), and operating temperature range (-40°C ~ 70°C). These parameters ensure direct functional compatibility within existing system designs.

Enhanced Specifications: The T18-2VPLP-9M provides improved response time (1.5ms and 750µs options versus 3ms) and extended sensing distance (6m versus 2m), offering performance advantages over the original part. The substitute also includes IEC IP68 certification in addition to the original NEMA 6P, IEC IP67, and IEC IP69 ratings, providing enhanced ingress protection capability.

Product Availability: The T18-2VPLP-9M holds active product status with current inventory availability, ensuring reliable sourcing for immediate and future requirements.

Frequently Asked Questions (FAQ)

Q: Can the T18-2VPLP-9M directly replace the T18SP6LP W/30 in existing installations?

A: Yes. Both parts share identical voltage supply range, output configuration, cable length, connection method, and operating temperature specifications. The substitute part maintains all core electrical and mechanical compatibility parameters required for direct substitution.

Q: What is the primary difference between these two sensors?

A: The T18-2VPLP-9M provides a 6-meter sensing distance compared to the 2-meter range of the T18SP6LP W/30. The substitute also offers faster response time options (1.5ms and 750µs versus 3ms) and includes IEC IP68 ingress protection certification in addition to the original ratings.

Q: Does the increased sensing distance of the substitute part affect compatibility?

A: No. Extended sensing distance does not compromise compatibility. The substitute part operates within the same voltage supply, output configuration, and environmental specifications. Applications requiring the original 2-meter range will function correctly with the extended-range substitute part.

Q: Are both parts RoHS compliant?

A: Yes. Both the T18SP6LP W/30 and T18-2VPLP-9M are RoHS compliant and REACH unaffected, maintaining regulatory compliance for restricted substance directives.

Q: What is the cable length for both parts?

A: Both parts feature identical 354.33-inch (9-meter) cable lengths, ensuring compatibility with existing cable routing and connection infrastructure.

Q: Why is the original part classified as obsolete?

A: The T18SP6LP W/30 is obsolete and no longer manufactured. The T18-2VPLP-9M represents the current active equivalent within the Banner Engineering Corporation T18 sensor product line.

Q: Are there any temperature or environmental limitations I should consider?

A: Both parts operate across the identical temperature range of -40°C to 70°C. The substitute part meets or exceeds all ingress protection requirements of the original part, including NEMA 6P, IEC IP67, IEC IP68, and IEC IP69 standards.