Request Quote
(Ships tomorrow)
T18SP6LP Equivalent & Substitute Parts
Part Overview
The T18SP6LP is a retroreflective, polarized optical sensor manufactured by Banner Engineering Corporation, designed for industrial detection applications. This sensor features a 2-meter (78.740") sensing distance with PNP output configuration supporting both Dark-ON and Light-ON selectable modes. The device operates across a 10V to 30V supply voltage range with a 3ms response time and includes a 2-meter cable with connector-based connection method.
The T18SP6LP is classified as obsolete. Locating equivalent substitute parts is necessary to maintain system functionality, ensure continued availability for replacement applications, and support long-term maintenance of installed equipment using this sensor model.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | T18SP6LP |
| Manufacturer | Banner Engineering Corporation |
| Category | Optical Sensors |
| Series | T18 |
| Product Status | Obsolete |
| Sensing Method | Retroreflective, Polarized |
| Sensing Distance | 78.740" (2m) |
| Voltage - Supply | 10V ~ 30V |
| Response Time | 3ms |
| Output Configuration | PNP - Dark-ON/Light-ON - Selectable |
| Light Source | Red (680nm) |
| Connection Method | Connector |
| Ingress Protection | NEMA 6P, IEC IP67, IEC IP69 |
| Cable Length | 78.74" (2m) |
| Operating Temperature | -40°C ~ 70°C |
| RoHS Status | RoHS Compliant |
| REACH Status | REACH Unaffected |
Substitute Part Grouping Explanation
Substitution of the T18SP6LP is based on maintaining compatibility across the following critical parameters:
Core Compatibility Criteria:
- Sensing method: Retroreflective, Polarized
- Output configuration: PNP with Dark-ON/Light-ON capability
- Supply voltage range: 10V ~ 30V
- Light source: Red wavelength
- Connection method: Cable-based connectivity
- Ingress protection rating: IEC IP67 minimum
- Operating temperature range: -40°C ~ 70°C
- RoHS and REACH compliance status
The T18-2VPLP-2M qualifies as a substitute part because it maintains all core compatibility criteria while offering enhanced performance characteristics in sensing distance and response time. Both sensors operate within identical voltage and temperature parameters, support equivalent output configurations, and meet the same environmental protection and regulatory compliance standards.
Parameter Comparison
| Parameter | T18SP6LP (Main Part) | T18-2VPLP-2M (Substitute) |
|---|---|---|
| Manufacturer | Banner Engineering Corporation | Banner Engineering Corporation |
| Category | Optical Sensors | Optical Sensors |
| Sensing Method | Retroreflective, Polarized | Retroreflective, Polarized |
| Sensing Distance | 78.740" (2m) | 236.22" (6m) |
| Voltage - Supply | 10V ~ 30V | 10V ~ 30V |
| Response Time | 3ms | 1.5ms |
| Output Configuration | PNP - Dark-ON/Light-ON - Selectable | PNP - Dark-ON/Light-ON |
| Light Source | Red (680nm) | Red LED |
| Connection Method | Connector | Cable |
| Ingress Protection | NEMA 6P, IEC IP67, IEC IP69 | IEC IP67, IEC IP68, IEC IP69K |
| Cable Length | 78.74" (2m) | 78.74" (2m) |
| Operating Temperature | -40°C ~ 70°C | -40°C ~ 70°C |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
Engineering Selection Recommendations
The T18-2VPLP-2M is an active product with current manufacturing status, whereas the T18SP6LP is obsolete. Selection of the T18-2VPLP-2M provides access to a currently supported sensor within the Banner Engineering T18 series family.
Both parts maintain identical supply voltage ranges (10V ~ 30V) and operating temperature specifications (-40°C ~ 70°C), ensuring compatibility with existing power supply and thermal management infrastructure. Both sensors are RoHS and REACH compliant, meeting current regulatory requirements for electronic component procurement.
The T18-2VPLP-2M offers enhanced ingress protection ratings (IEC IP68 and IEC IP69K) compared to the original part, providing superior environmental sealing for applications requiring extended moisture and pressure resistance. The substitute part also delivers faster response time (1.5ms versus 3ms) and extended sensing distance capability (236.22" versus 78.740"), which may provide operational advantages in detection range and system responsiveness without introducing compatibility constraints.
Both sensors utilize retroreflective, polarized sensing methodology with red light sources and PNP output configurations, maintaining functional equivalence for detection logic and optical system design.
Frequently Asked Questions (FAQ)
Q: Can the T18-2VPLP-2M directly replace the T18SP6LP in existing installations?
A: Yes. Both sensors operate on identical 10V ~ 30V supply voltages, support equivalent PNP output configurations with Dark-ON/Light-ON capability, and maintain the same operating temperature range (-40°C ~ 70°C). Cable length specifications are identical at 78.74" (2m). The connection method differs (cable versus connector), which may require mechanical interface adaptation depending on the installation configuration.
Q: What are the key differences between these two sensors?
A: The T18-2VPLP-2M provides three primary enhancements: extended sensing distance (236.22" versus 78.740"), faster response time (1.5ms versus 3ms), and improved ingress protection ratings (IEC IP68 and IEC IP69K versus IEC IP67 and IEC IP69). The T18SP6LP features a connector-based connection method, while the T18-2VPLP-2M uses a cable connection method.
Q: Are there any compliance or regulatory differences between these parts?
A: Both sensors are RoHS and REACH compliant. The T18-2VPLP-2M carries ROHS3 compliance designation, representing the current RoHS standard revision. Both parts meet equivalent environmental and regulatory requirements for industrial electronic component applications.
Q: Does the increased sensing distance of the T18-2VPLP-2M affect compatibility?
A: No. Extended sensing distance does not create compatibility issues. The substitute part maintains all core electrical and operational parameters required for functional equivalence. The greater sensing range provides additional capability without introducing constraints to existing system designs.
Q: What is the significance of the connection method difference?
A: The T18SP6LP uses a connector-based connection, while the T18-2VPLP-2M uses a cable connection method. This difference requires mechanical interface consideration during installation. The cable length is identical (78.74" / 2m) for both parts, but the connection interface type may necessitate adapter or wiring modifications depending on the existing installation infrastructure.
Q: Why is the T18SP6LP classified as obsolete?
A: The T18SP6LP is no longer in active production. The T18-2VPLP-2M represents the current active product offering within the Banner Engineering T18 series, providing equivalent functionality with enhanced performance characteristics and current manufacturing support.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts