Request Quote
(Ships tomorrow)
T18SP6L Equivalent & Substitute Parts
Part Overview
The T18SP6L is a retroreflective, non-polarized optical sensor manufactured by Banner Engineering Corporation, part of the T18 series. This sensor operates at supply voltages between 10V and 30V with a sensing distance of 78.740" (2m) and features selectable Dark-ON/Light-ON output configuration via PNP logic. The device utilizes infrared light source technology and includes adjustable potentiometer-based tuning.
The T18SP6L is classified as obsolete. Locating equivalent or substitute components is necessary to support legacy system maintenance, ensure continued operational capability, and facilitate component procurement for repair and replacement applications.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Banner Engineering Corporation |
| Series | T18 |
| Product Status | Obsolete |
| Sensing Method | Retroreflective, Non-Polarized |
| Sensing Distance | 78.740" (2m) |
| Voltage Supply Range | 10V ~ 30V |
| Output Configuration | PNP - Dark-ON/Light-ON - Selectable |
| Light Source | Infrared |
| Response Time | 3ms |
| Operating Temperature Range | -40°C ~ 70°C |
| Ingress Protection Rating | NEMA 6P, IEC IP67, IEC IP69K |
| Adjustment Type | Adjustable, Potentiometer |
| Connection Method | Cable |
Substitute Part Grouping Explanation
Substitution of the T18SP6L with the T18-2VPLPC-Q8 is based on the following alignment of critical electrical and mechanical parameters:
Compatible Parameters:
- Manufacturer: Both parts manufactured by Banner Engineering Corporation
- Output Configuration: Both feature PNP - Dark-ON/Light-ON - Selectable logic
- Voltage Supply Range: Both operate within 10V ~ 30V
- Operating Temperature Range: Both rated -40°C ~ 70°C
- Ingress Protection: Both meet NEMA 6P, IEC IP67, IEC IP69K standards
- Adjustment Type: Both include adjustable potentiometer tuning
- Sensing Method: Both employ retroreflective technology
Differing Parameters:
- Series: T18SP6L belongs to T18 series; T18-2VPLPC-Q8 belongs to T18-2 series
- Sensing Distance: T18SP6L operates at 78.740" (2m); T18-2VPLPC-Q8 operates at 236.220" (6m)
- Response Time: T18SP6L has 3ms response; T18-2VPLPC-Q8 has 1.5ms response
- Light Source: T18SP6L uses Infrared; T18-2VPLPC-Q8 uses Red (624nm)
- Polarization: T18SP6L is non-polarized; T18-2VPLPC-Q8 is polarized
- Connection Method: T18SP6L uses cable; T18-2VPLPC-Q8 uses connector
- Product Status: T18SP6L is obsolete; T18-2VPLPC-Q8 is active
Parameter Comparison
| Parameter | T18SP6L (Main Part) | T18-2VPLPC-Q8 (Substitute) |
|---|---|---|
| Manufacturer | Banner Engineering Corporation | Banner Engineering Corporation |
| Category | Optical Sensors | Optical Sensors |
| Sensing Method | Retroreflective, Non-Polarized | Retroreflective, Polarized |
| Sensing Distance | 78.740" (2m) | 236.220" (6m) |
| Voltage Supply | 10V ~ 30V | 10V ~ 30V |
| Response Time | 3ms | 1.5ms |
| Output Configuration | PNP - Dark-ON/Light-ON - Selectable | PNP - Dark-ON/Light-ON - Selectable |
| Light Source | Infrared | Red (624nm) |
| Connection Method | Cable | Connector |
| Ingress Protection | NEMA 6P, IEC IP67, IEC IP69K | NEMA 6P, IEC IP67, IEC IP69K |
| Adjustment Type | Adjustable, Potentiometer | Adjustable, Potentiometer |
| Operating Temperature | -40°C ~ 70°C | -40°C ~ 70°C |
| Product Status | Obsolete | Active |
| RoHS Status | Not specified | ROHS3 Compliant |
| REACH Status | REACH Unaffected | Vendor Undefined |
Engineering Selection Recommendations
The T18-2VPLPC-Q8 serves as an active substitute for the obsolete T18SP6L. Both components share identical voltage supply ranges, output logic configurations, operating temperature specifications, and ingress protection ratings, establishing functional compatibility at the electrical interface level.
The T18-2VPLPC-Q8 is classified as active product status with ROHS3 compliance, supporting current procurement and long-term supply chain continuity. The T18SP6L, designated as obsolete, presents supply constraints and limited availability for new applications.
Key differences in sensing distance (236.220" versus 78.740"), response time (1.5ms versus 3ms), light source technology (red versus infrared), and polarization characteristics (polarized versus non-polarized) must be evaluated against specific application requirements. The connector-based connection method of the T18-2VPLPC-Q8 differs from the cable connection of the T18SP6L, requiring mechanical interface assessment during integration.
Frequently Asked Questions (FAQ)
Q: Can the T18-2VPLPC-Q8 directly replace the T18SP6L in existing installations?
A: Electrical compatibility exists due to matching voltage supply ranges (10V ~ 30V), identical output logic (PNP - Dark-ON/Light-ON - Selectable), and equivalent operating temperature ratings (-40°C ~ 70°C). However, mechanical integration requires evaluation of the connection method change from cable to connector, and application-specific sensing distance requirements must be confirmed.
Q: What are the primary differences between these two optical sensors?
A: The T18-2VPLPC-Q8 provides extended sensing distance (236.220" versus 78.740"), faster response time (1.5ms versus 3ms), polarized retroreflective technology versus non-polarized, and red light source (624nm) instead of infrared. The T18-2VPLPC-Q8 uses connector-based connection while the T18SP6L uses cable connection.
Q: Does the increased sensing distance of the T18-2VPLPC-Q8 affect compatibility?
A: Extended sensing distance does not prevent substitution but may alter detection behavior in applications designed for the shorter 2m range of the T18SP6L. Application-specific validation is necessary to confirm performance alignment with system requirements.
Q: What compliance certifications apply to the substitute part?
A: The T18-2VPLPC-Q8 is ROHS3 compliant. Both the main part and substitute meet NEMA 6P, IEC IP67, and IEC IP69K ingress protection standards. REACH status for the substitute is vendor-defined.
Q: How does the polarization difference impact sensor operation?
A: The T18SP6L employs non-polarized retroreflective sensing, while the T18-2VPLPC-Q8 uses polarized retroreflective technology. Polarized sensors provide enhanced rejection of ambient light interference. Application environments with high ambient light exposure may benefit from the polarized design of the substitute.
Q: What is the significance of the connection method change from cable to connector?
A: The T18SP6L features direct cable connection, while the T18-2VPLPC-Q8 uses a connector interface. System integration requires mechanical compatibility assessment and potential wiring reconfiguration to accommodate the connector-based connection method.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts