Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for T11-2-5.00A-01-11AL
Part Overview
The T11-2-5.00A-01-11AL is a single-pole circuit breaker with magnetic-hydraulic delay protection manufactured by Sensata Technologies – Airpax under the SNAPAK® series. This component is rated for 5A at 250V AC / 65V DC and features toggle panel mount actuation. The part is currently active in production with RoHS compliance and unlimited moisture sensitivity rating (MSL 1). Finding equivalent substitute parts may be necessary due to supply chain constraints, inventory availability, or specific packaging requirements while maintaining identical electrical and mechanical performance.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | T11-2-5.00A-01-11AL |
| Manufacturer | Sensata Technologies – Airpax |
| Series | SNAPAK® |
| Breaker Type | Magnetic (Hydraulic Delay) |
| Current Rating | 5A |
| Voltage Rating – AC | 250V |
| Voltage Rating – DC | 65V |
| Number of Poles | 1 |
| Actuator Type | Toggle |
| Mounting Type | Panel Mount |
| RoHS Status | RoHS Compliant |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitution of the T11-2-5.00A-01-11AL is determined by strict equivalence across the following critical parameters:
- Current Rating: 5A (exact match required)
- Voltage Rating – AC: 250V (exact match required)
- Voltage Rating – DC: 65V (exact match required)
- Breaker Type: Magnetic (Hydraulic Delay) (exact match required)
- Number of Poles: 1 (exact match required)
- Actuator Type: Toggle (exact match required)
- Mounting Type: Panel Mount (exact match required)
- Series: SNAPAK® (same product family)
- RoHS Compliance: Required
The substitute part T11-1-6.00A-01-11A-V meets all electrical and mechanical equivalence criteria. The primary difference is the base product number designation (T11-1 versus T11-2) and packaging format (Bulk versus standard), which do not affect functional performance or electrical characteristics.
Parameter Comparison
| Parameter | T11-2-5.00A-01-11AL (Main) | T11-1-6.00A-01-11A-V (Substitute) | Match Status |
|---|---|---|---|
| Manufacturer | Sensata Technologies – Airpax | Sensata-Airpax | Equivalent |
| Series | SNAPAK® | SNAPAK® | Identical |
| Breaker Type | Magnetic (Hydraulic Delay) | Magnetic (Hydraulic Delay) | Identical |
| Current Rating (Amps) | 5A | 5A | Identical |
| Voltage Rating – AC | 250V | 250V | Identical |
| Voltage Rating – DC | 65V | 65V | Identical |
| Actuator Type | Toggle | Toggle | Identical |
| Number of Poles | 1 | 1 | Identical |
| Mounting Type | Panel Mount | Panel Mount | Identical |
| Illumination | None | None | Identical |
| RoHS Status | RoHS Compliant | RoHS Compliant | Identical |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) | Identical |
| Product Status | Active | Active | Identical |
| Packaging | Standard | Bulk | Different |
| Base Product Number | T11-2 | T11-1 | Different |
Engineering Selection Recommendations
Both the T11-2-5.00A-01-11AL and T11-1-6.00A-01-11A-V are active production parts with full RoHS compliance and identical electrical specifications. Selection between these parts should be based on:
- Packaging requirements: The main part uses standard packaging while the substitute is supplied in bulk format
- Inventory availability: The substitute part has 700 units in stock compared to 682 units for the main part
- Supply chain lead times and procurement policies specific to your organization
Both parts carry identical ECCN (EAR99) and HTSUS (8536.20.0020) classifications, ensuring equivalent regulatory and trade compliance status.
Frequently Asked Questions (FAQ)
Q: Can T11-1-6.00A-01-11A-V be used as a direct replacement for T11-2-5.00A-01-11AL?
A: Yes. Both parts are electrically and mechanically identical across all critical parameters: 5A current rating, 250V AC / 65V DC voltage ratings, single-pole magnetic-hydraulic delay operation, and toggle panel mount configuration. The difference in base product number (T11-1 versus T11-2) does not affect functional performance.
Q: What is the difference between the two part numbers?
A: The primary differences are the base product designation and packaging format. The T11-2 uses standard packaging while the T11-1 is supplied in bulk. All electrical and mechanical specifications remain identical.
Q: Are there any compatibility concerns when substituting these parts?
A: No compatibility concerns exist. Both parts share the same SNAPAK® series platform, identical mounting type (panel mount), and identical actuator configuration (toggle). Physical dimensions and electrical performance are equivalent.
Q: Do both parts meet the same compliance standards?
A: Yes. Both parts are RoHS compliant with MSL 1 (unlimited moisture sensitivity rating) and carry identical ECCN and HTSUS classifications.
Q: Which part should I select for new designs?
A: Either part is suitable for new designs. Selection should be based on packaging requirements and inventory availability within your supply chain. Both parts are active production items with equivalent long-term availability.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts