SZX-SLF-08N Relay Socket 8 Position DIN Rail - Equivalent & Substitute Parts

Part Overview

The SZX-SLF-08N is an 8-position relay socket manufactured by Honeywell Sensing and Productivity Solutions, designed for DIN rail mounting applications. This component is classified as obsolete, making identification of equivalent substitute parts essential for ongoing system maintenance and new design implementations. The socket accommodates screw terminal connections and is compatible with the SZR-LY series relay family. Due to its obsolete status, sourcing equivalent active alternatives ensures supply chain continuity and long-term component availability.

Substiute Parts

SZX-SLF-08N
Honeywell Sensing and Productivity SolutionsIn Stock: 631SZX-SLF-08N Datasheet
SZX-SLF-08N
Current Part
PTF08A
Omron Automation and SafetyIn Stock: 4600PTF08A Datasheet
PTF08A
Similar

Key Parameters

Parameter Value
Manufacturer Part Number SZX-SLF-08N
Manufacturer Honeywell Sensing and Productivity Solutions
Product Type Relay Socket
Number of Positions 8
Mounting Type DIN Rail
Termination Style Screw Terminal
Series SZR-LY
Product Status Obsolete
RoHS Status RoHS Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the SZX-SLF-08N is determined by the following critical parameters:

Primary Matching Criteria:

  • Number of Positions: 8
  • Mounting Type: DIN Rail
  • Termination Style: Screw Terminal
  • Product Type: Relay Socket

Secondary Compliance Criteria:

  • RoHS Compliance Status
  • Moisture Sensitivity Level: 1 (Unlimited)
  • ECCN Classification: EAR99

The PTF08A manufactured by Omron Automation and Safety satisfies all primary matching criteria and maintains equivalent compliance certifications. Both components are classified under ECCN EAR99 and possess MSL rating of 1, indicating identical environmental handling requirements. The PTF08A is compatible with LY series relays, which aligns with the SZR-LY series compatibility of the original part.

Parameter Comparison

Parameter SZX-SLF-08N (Honeywell) PTF08A (Omron)
Manufacturer Part Number SZX-SLF-08N PTF08A
Manufacturer Honeywell Sensing and Productivity Solutions Omron Automation and Safety
Number of Positions 8 8
Mounting Type DIN Rail DIN Rail
Termination Style Screw Terminal Screw Terminal
Product Type Socket Socket
Product Status Obsolete Active
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited)
ECCN Classification EAR99 EAR99
Series Compatibility SZR-LY Series LY Series, SPDT/DPDT

Engineering Selection Recommendations

For Obsolete Component Replacement:

The PTF08A represents a direct functional equivalent for the SZX-SLF-08N. Both components share identical electrical and mechanical specifications across all critical parameters: 8-position configuration, DIN rail mounting, and screw terminal termination. The PTF08A maintains active product status, ensuring continued availability and manufacturer support.

Compliance Considerations:

Both components satisfy RoHS requirements. The PTF08A carries ROHS3 certification, representing the current regulatory standard, while the SZX-SLF-08N holds RoHS Compliant status. Both components are classified as ECCN EAR99 and carry identical MSL ratings, confirming equivalent environmental and regulatory handling requirements.

Supply Chain Advantage:

The PTF08A is currently in active production with 4,563 units in stock, compared to the obsolete SZX-SLF-08N with limited remaining inventory of 621 units. Selection of the PTF08A ensures long-term component availability for maintenance and future production requirements.

Frequently Asked Questions (FAQ)

Q: Can the PTF08A directly replace the SZX-SLF-08N in existing installations?

A: Yes. Both components are 8-position relay sockets with DIN rail mounting and screw terminal termination. The electrical and mechanical interfaces are equivalent, allowing direct substitution in applications designed for the SZX-SLF-08N.

Q: What is the significance of the obsolete status of the SZX-SLF-08N?

A: Obsolete status indicates that Honeywell has discontinued manufacturing and support for this component. The PTF08A, classified as active, ensures continued availability, technical support, and supply chain reliability for new designs and ongoing maintenance.

Q: Are there differences in RoHS compliance between these components?

A: Both components are RoHS compliant. The PTF08A carries ROHS3 certification, representing the current regulatory iteration, while the SZX-SLF-08N holds RoHS Compliant status. Both satisfy current regulatory requirements for restricted substance limitations.

Q: What does MSL 1 (Unlimited) indicate?

A: Moisture Sensitivity Level 1 indicates the lowest moisture sensitivity classification. Both components require no special moisture control during storage, handling, or installation, simplifying logistics and inventory management.

Q: Are there packaging differences between the SZX-SLF-08N and PTF08A?

A: The SZX-SLF-08N is supplied in standard packaging, while the PTF08A is supplied in bulk packaging. Bulk packaging does not affect component functionality or electrical performance; it reflects inventory and distribution practices.

Q: Is the PTF08A compatible with SZR-LY series relays?

A: The PTF08A is specified for LY series relays, which encompasses the SZR-LY series compatibility. The socket accommodates SPDT/DPDT relay configurations within the LY family, ensuring functional compatibility with the original application.

Q: What export classification applies to both components?

A: Both the SZX-SLF-08N and PTF08A are classified under ECCN EAR99, indicating they are subject to standard export control regulations without specific licensing requirements for most destinations.

Request Quote (Ships tomorrow)