Request Quote
(Ships tomorrow)
STR-A6069HZ Equivalent & Substitute Parts
Part Overview
The STR-A6069HZ is an AC/DC converter integrated circuit manufactured by Sanken Electric USA Inc., designed for offline flyback topology applications. This isolated power management IC operates at 100 kHz switching frequency with 30 W output power capability and includes internal switching functionality. The device is classified as Active product status with full RoHS3 compliance and REACH unaffected designation. Substitute parts are identified when equivalent electrical and mechanical parameters align with application requirements, enabling component interchangeability in circuit designs where the primary part becomes unavailable or inventory constraints necessitate alternative sourcing.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | STR-A6069HZ |
| Manufacturer | Sanken Electric USA Inc. |
| Category | Power Management (PMIC) |
| Topology | Flyback |
| Output Isolation | Isolated |
| Internal Switch(s) | Yes |
| Voltage - Breakdown | 700V |
| Voltage - Supply (Vcc/Vdd) | 8.5V ~ 32V |
| Voltage - Start Up | 47 V |
| Frequency - Switching | 100 kHz |
| Power (Watts) | 30 W |
| Duty Cycle | 75% |
| Fault Protection | Current Limiting, Over Load, Over Temperature, Over Voltage |
| Control Features | Soft Start |
| Operating Temperature | -40°C ~ 125°C (TA) |
| Package / Case | 8-DIP (0.300", 7.62mm), 7 Leads |
| Mounting Type | Through Hole |
| RoHS Status | RoHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| Product Status | Active |
Substitute Part Grouping Explanation
Substitution eligibility for the STR-A6069HZ is determined by strict alignment of the following critical parameters:
Mandatory Matching Parameters:
- Topology: Flyback
- Output Isolation: Isolated
- Internal Switch(s): Yes
- Voltage - Breakdown: 700V
- Voltage - Supply (Vcc/Vdd): 8.5V ~ 32V
- Duty Cycle: 75%
- Frequency - Switching: 100 kHz
- Fault Protection: Current Limiting, Over Load, Over Temperature, Over Voltage
- Control Features: Soft Start
- Operating Temperature: -40°C ~ 125°C (TA)
- Package / Case: 8-DIP (0.300", 7.62mm), 7 Leads
- Mounting Type: Through Hole
- RoHS Status: RoHS3 Compliant
- Moisture Sensitivity Level (MSL): 1 (Unlimited)
- REACH Status: REACH Unaffected
Variable Parameters (Allowable Differences):
- Power (Watts): 30 W to 40 W range
- Voltage - Start Up: 15 V to 47 V range
All substitute parts listed maintain identical electrical topology, isolation characteristics, protection features, and package specifications. Variations in power rating and startup voltage reflect design flexibility within the STR-A606x and STR6A16x series families while preserving core functional compatibility.
Parameter Comparison
| Parameter | STR-A6069HZ | STR-A6063HZ | STR6A161HVD | STR6A161HZ | STR6A169HZ |
|---|---|---|---|---|---|
| Manufacturer | Sanken Electric USA Inc. | Sanken Electric USA Inc. | Sanken Electric USA Inc. | Sanken Electric USA Inc. | Sanken Electric USA Inc. |
| Category | Power Management (PMIC) | Power Management (PMIC) | Power Management (PMIC) | Power Management (PMIC) | Power Management (PMIC) |
| Topology | Flyback | Flyback | Flyback | Flyback | Flyback |
| Output Isolation | Isolated | Isolated | Isolated | Isolated | Isolated |
| Internal Switch(s) | Yes | Yes | Yes | Yes | Yes |
| Voltage - Breakdown | 700V | 700V | 700V | 700V | 700V |
| Voltage - Supply (Vcc/Vdd) | 8.5V ~ 32V | 8.5V ~ 32V | 8.5V ~ 32V | 8.5V ~ 32V | 8.5V ~ 32V |
| Voltage - Start Up | 47 V | 47 V | 47 V | 15 V | 15 V |
| Frequency - Switching | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz |
| Power (Watts) | 30 W | 40 W | 35 W | 35 W | 30 W |
| Duty Cycle | 75% | 75% | 75% | 75% | 75% |
| Fault Protection | Current Limiting, Over Load, Over Temperature, Over Voltage | Current Limiting, Over Load, Over Temperature, Over Voltage | Current Limiting, Over Load, Over Temperature, Over Voltage | Current Limiting, Over Load, Over Temperature, Over Voltage | Current Limiting, Over Load, Over Temperature, Over Voltage |
| Control Features | Soft Start | Soft Start | Soft Start | Soft Start | Soft Start |
| Operating Temperature | -40°C ~ 125°C (TA) | -40°C ~ 125°C (TA) | -40°C ~ 125°C (TA) | -40°C ~ 125°C (TA) | -40°C ~ 125°C (TA) |
| Package / Case | 8-DIP (0.300", 7.62mm), 7 Leads | 8-DIP (0.300", 7.62mm), 7 Leads | 8-DIP (0.300", 7.62mm), 7 Leads | 8-DIP (0.300", 7.62mm), 7 Leads | 8-DIP (0.300", 7.62mm), 7 Leads |
| Mounting Type | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole |
| RoHS Status | RoHS3 Compliant | RoHS3 Compliant | RoHS3 Compliant | RoHS3 Compliant | RoHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected | REACH Unaffected |
| Product Status | Active | Active | Active | Active | Active |
Engineering Selection Recommendations
All listed substitute parts maintain Active product status with full RoHS3 compliance and REACH unaffected designation, ensuring regulatory alignment with the primary STR-A6069HZ device. Selection between substitute options is determined by application-specific power requirements and startup voltage specifications.
STR-A6063HZ provides 40 W output power with 47 V startup voltage, suitable for applications requiring higher power delivery while maintaining identical electrical characteristics and package form factor.
STR6A161HVD delivers 35 W output power with 47 V startup voltage, offering intermediate power capability between the 30 W and 40 W options within the same startup voltage class.
STR6A161HZ provides 35 W output power with reduced 15 V startup voltage, enabling operation in lower supply voltage environments while preserving all protection and control features.
STR6A169HZ matches the 30 W power rating of the primary part with reduced 15 V startup voltage, providing direct functional equivalence with enhanced low-voltage startup capability.
All substitute parts share identical 8-DIP through-hole packaging, enabling direct PCB layout compatibility without redesign. Compliance certifications, fault protection mechanisms, and thermal operating ranges remain constant across all options.
Frequently Asked Questions (FAQ)
Q: Can STR-A6063HZ replace STR-A6069HZ in existing designs?
A: STR-A6063HZ is electrically compatible with identical topology, isolation, switching frequency, and protection features. The primary difference is increased power rating (40 W versus 30 W). Substitution is valid when the application circuit can accommodate the higher power capability. Both parts share identical 8-DIP package specifications and through-hole mounting requirements.
Q: What is the difference between STR6A161HVD and STR6A161HZ?
A: Both parts deliver 35 W output power with identical topology and package specifications. The primary distinction is startup voltage: STR6A161HVD requires 47 V startup while STR6A161HZ operates with 15 V startup. Selection depends on the minimum supply voltage available in the target application circuit.
Q: Are STR6A161HZ and STR6A169HZ interchangeable?
A: Both parts feature 15 V startup voltage and 8-DIP through-hole packaging. The difference is power rating: STR6A161HZ provides 35 W while STR6A169HZ provides 30 W. Substitution of STR6A161HZ for STR6A169HZ is valid when higher power capability is acceptable. Reverse substitution (STR6A169HZ for STR6A161HZ) requires circuit verification to confirm 30 W power delivery meets application requirements.
Q: Do all substitute parts maintain the same fault protection?
A: All listed substitute parts include identical fault protection mechanisms: current limiting, overload protection, over-temperature protection, and over-voltage protection. Soft start control features are present across all options.
Q: Is PCB layout modification required when substituting parts?
A: No PCB layout modification is required. All substitute parts use identical 8-DIP (0.300", 7.62mm) package specifications with 7 leads and through-hole mounting. Direct pin-for-pin substitution is supported without redesign.
Q: What is the operating temperature range for all substitute parts?
A: All substitute parts operate across the identical temperature range of -40°C to 125°C (TA), ensuring thermal compatibility in applications requiring extended temperature operation.
Q: Are all substitute parts RoHS3 compliant?
A: All listed substitute parts maintain RoHS3 compliance and REACH unaffected status, matching the regulatory designation of the primary STR-A6069HZ device.
Q: Which substitute part should be selected for lowest startup voltage?
A: Both STR6A161HZ and STR6A169HZ feature 15 V startup voltage, the lowest among all options. STR6A161HZ provides 35 W power while STR6A169HZ provides 30 W. Selection depends on required power delivery for the specific application.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts