ST250PG1SPRF Equivalent & Substitute Parts

Part Overview

The ST250PG1SPRF is a vented gauge pressure sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for industrial automation applications requiring 0-250 PSI measurement capability. This sensor delivers amplified analog voltage output with temperature compensation across an operating range of -40°C to 100°C. The product is classified as obsolete, necessitating identification of functionally equivalent active alternatives that maintain compatibility with existing system requirements.

Substiute Parts

ST250PG1SPRF
Honeywell Sensing and Productivity SolutionsIn Stock: 845ST250PG1SPRF Datasheet
ST250PG1SPRF
Current Part
M3041-000006-250PG
TE Connectivity Measurement SpecialtiesIn Stock: 908M3041-000006-250PG Datasheet
M3041-000006-250PG
Similar

Key Parameters

Parameter Value
Operating Pressure Range 250 PSI (1723.69 kPa)
Pressure Type Vented Gauge
Output Type Analog Voltage
Output Voltage Range 0.5 V ~ 4.5 V
Accuracy ±1%
Supply Voltage 7 V ~ 35 V
Port Connection Male 1/8" (3.18 mm) NPT Threaded
Maximum Pressure Rating 500 PSI (3447.38 kPa)
Operating Temperature -40°C ~ 100°C
Package Type Cylinder, Metal
Features Amplified Output, Temperature Compensated
RoHS Status RoHS Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the ST250PG1SPRF is determined by strict alignment of the following critical parameters:

Mandatory Matching Parameters:

  • Operating pressure range: 250 PSI nominal
  • Pressure type: Vented gauge configuration
  • Output type: Analog voltage signal
  • Accuracy specification: ±1%
  • Port connection: Male 1/8" NPT threaded interface
  • Maximum pressure rating: 500 PSI minimum
  • Features: Amplified output with temperature compensation

Allowable Variation Parameters:

  • Output voltage range (within system signal conditioning tolerance)
  • Supply voltage range (within available power supply capability)
  • Operating temperature range (application-dependent minimum requirements)
  • Package configuration (mechanical form factor compatibility)
  • Termination style (connector type compatibility)

The substitute part M3041-000006-250PG meets all mandatory matching parameters while maintaining functional equivalence for industrial automation pressure measurement applications.

Parameter Comparison

Parameter ST250PG1SPRF (Honeywell) M3041-000006-250PG (TE Connectivity) Compatibility Status
Operating Pressure 250 PSI (1723.69 kPa) 250 PSI (1723.69 kPa) Identical
Pressure Type Vented Gauge Vented Gauge Identical
Output Type Analog Voltage Analog Voltage Identical
Output Voltage Range 0.5 V ~ 4.5 V 1 V ~ 5 V Compatible (overlapping range)
Accuracy ±1% ±1% Identical
Supply Voltage 7 V ~ 35 V 10 V ~ 30 V Compatible (overlapping range)
Port Size Male 1/8" (3.18 mm) NPT Male 1/8" (3.18 mm) NPT Identical
Port Style Threaded Threaded Identical
Maximum Pressure 500 PSI (3447.38 kPa) 500 PSI (3447.38 kPa) Identical
Features Amplified Output, Temperature Compensated Amplified Output, Temperature Compensated Identical
Operating Temperature -40°C ~ 100°C -20°C ~ 85°C Substitute range narrower; suitable for applications within -20°C ~ 85°C
RoHS Status RoHS Compliant ROHS3 Compliant Both compliant
Product Status Obsolete Active Substitute is currently manufactured

Engineering Selection Recommendations

The M3041-000006-250PG from TE Connectivity Measurement Specialties (MSP300 series) qualifies as a direct functional substitute for the obsolete ST250PG1SPRF based on the following engineering criteria:

Compliance and Availability:

  • The substitute part maintains active product status with current manufacturing availability, eliminating supply chain risk associated with the obsolete main part
  • Both parts carry equivalent RoHS compliance certifications (RoHS Compliant and ROHS3 Compliant), satisfying regulatory requirements
  • Both parts share identical ECCN (EAR99) and HTSUS (9026.20.4000) classifications

Functional Equivalence:

  • Identical operating pressure specification (250 PSI) and pressure type (vented gauge)
  • Matching accuracy specification (±1%) and output type (analog voltage)
  • Identical port interface (Male 1/8" NPT threaded connection)
  • Identical maximum pressure rating (500 PSI)
  • Identical feature set (amplified output with temperature compensation)

Parameter Compatibility Considerations:

  • Output voltage range difference (0.5-4.5 V vs. 1-5 V) is compatible within typical signal conditioning systems
  • Supply voltage range difference (7-35 V vs. 10-30 V) is compatible within the overlapping 10-30 V window
  • Operating temperature range of the substitute (-20°C to 85°C) is narrower than the main part (-40°C to 100°C); applications requiring operation below -20°C or above 85°C require alternative solutions

Selection of the M3041-000006-250PG is appropriate for industrial automation pressure measurement applications operating within the -20°C to 85°C temperature window with supply voltages in the 10-30 V range.

Frequently Asked Questions (FAQ)

Q: What makes M3041-000006-250PG a valid substitute for ST250PG1SPRF?

A: Both sensors share identical operating pressure (250 PSI), pressure type (vented gauge), output type (analog voltage), accuracy (±1%), port interface (Male 1/8" NPT), maximum pressure rating (500 PSI), and feature set (amplified output with temperature compensation). These parameters define functional equivalence for industrial automation pressure measurement applications.

Q: Are there differences in output voltage between these sensors?

A: Yes. The ST250PG1SPRF outputs 0.5-4.5 V, while the M3041-000006-250PG outputs 1-5 V. Both ranges overlap significantly (1-4.5 V), making them compatible with standard industrial signal conditioning and analog-to-digital conversion systems. System design must account for the different output scaling.

Q: What is the temperature operating range difference?

A: The ST250PG1SPRF operates from -40°C to 100°C, while the M3041-000006-250PG operates from -20°C to 85°C. The substitute part has a narrower range. Applications requiring operation below -20°C or above 85°C cannot use the M3041-000006-250PG and require alternative solutions.

Q: Are the supply voltage requirements compatible?

A: The ST250PG1SPRF requires 7-35 V, while the M3041-000006-250PG requires 10-30 V. The overlapping range is 10-30 V. Systems operating within this window are compatible. Systems requiring operation below 10 V or above 30 V must evaluate alternative parts.

Q: Can I use the M3041-000006-250PG as a direct mechanical replacement?

A: Both sensors use identical Male 1/8" NPT threaded port connections and cylinder metal package configurations, enabling direct mechanical installation. Termination style differs (the substitute includes cable termination), requiring evaluation of connector compatibility with existing wiring harnesses.

Q: What is the inventory status of these parts?

A: The ST250PG1SPRF (obsolete) has 829 pieces in stock. The M3041-000006-250PG (active product) has 866 pieces in stock. The active product status of the substitute ensures long-term availability for future procurement.

Q: Are both parts RoHS compliant?

A: Yes. The ST250PG1SPRF is RoHS Compliant, and the M3041-000006-250PG is ROHS3 Compliant. Both meet current regulatory requirements for restricted substance elimination.

Request Quote (Ships tomorrow)