Request Quote
(Ships tomorrow)
ST150PG2BPCF Equivalent & Substitute Parts
Part Overview
The ST150PG2BPCF is a vented gauge pressure sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for industrial automation applications. This sensor provides analog voltage output in the 0.5 V to 4.5 V range with ±1% accuracy across a 0–150 PSI operating pressure range. The product is classified as obsolete, necessitating identification of functionally equivalent alternatives for continued system support and component procurement.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Operating Pressure Range | 0–150 PSI (1034.21 kPa) |
| Pressure Type | Vented Gauge |
| Output Type | Analog Voltage |
| Output Voltage Range | 0.5 V – 4.5 V |
| Accuracy | ±1% |
| Supply Voltage | 5 V |
| Port Size | Male – 1/4" (6.35 mm) NPT |
| Port Style | Threaded |
| Operating Temperature Range | –40°C to 100°C |
| Maximum Pressure | 450 PSI (3102.64 kPa) |
| Features | Amplified Output, Temperature Compensated |
| Package Type | Cylinder, Metal |
| RoHS Status | RoHS Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the ST150PG2BPCF is determined by the following critical parameters:
Mandatory Matching Parameters:
- Operating pressure range: 0–150 PSI minimum
- Pressure type: Vented gauge configuration
- Output type: Analog voltage signal
- Port size and style: Male 1/4" NPT threaded connection
- Package form factor: Cylinder configuration
Compatible Variation Parameters:
- Output voltage range: May differ from 0.5–4.5 V if system signal conditioning accommodates the alternative range
- Supply voltage: May differ if power supply capability exists
- Accuracy: May be superior (tighter tolerance) to ±1%
- Operating temperature range: May be narrower than –40°C to 100°C
- Maximum pressure rating: May exceed 450 PSI
The IPSU-GP150-6 manufactured by Sensata-Cynergy3 satisfies all mandatory matching parameters and qualifies as a functional equivalent.
Parameter Comparison
| Parameter | ST150PG2BPCF (Honeywell) | IPSU-GP150-6 (Sensata-Cynergy3) | Compatibility Notes |
|---|---|---|---|
| Operating Pressure | 0–150 PSI | 0–150 PSI | Identical |
| Pressure Type | Vented Gauge | Vented Gauge | Identical |
| Output Type | Analog Voltage | Analog Voltage | Identical |
| Output Voltage Range | 0.5 V – 4.5 V | 0 V – 5 V | Different ranges; signal conditioning required |
| Accuracy | ±1% | ±0.25% | IPSU-GP150-6 provides superior accuracy |
| Supply Voltage | 5 V | 9 V – 32 V | Different supply requirements; IPSU-GP150-6 requires wider supply range |
| Port Size | Male – 1/4" NPT | Male – 1/4" NPT | Identical |
| Port Style | Threaded | Threaded | Identical |
| Operating Temperature | –40°C to 100°C | –20°C to 80°C | IPSU-GP150-6 has narrower temperature range |
| Maximum Pressure | 450 PSI | 300 PSI | ST150PG2BPCF has higher overpressure rating |
| Features | Amplified Output, Temperature Compensated | Amplified Output, Temperature Compensated | Identical |
| Package Type | Cylinder, Metal | Cylinder | Compatible form factors |
| RoHS Status | RoHS Compliant | ROHS3 Compliant | Both compliant; IPSU-GP150-6 meets current standard |
Engineering Selection Recommendations
ST150PG2BPCF (Original Part): Retain for applications where the specific output voltage range (0.5–4.5 V), 5 V single supply voltage, extended low-temperature operation (–40°C), and 450 PSI overpressure rating are system requirements. Product status is obsolete; procurement availability is limited.
IPSU-GP150-6 (Substitute Part): Select for new designs or system upgrades where the following conditions are met:
- Signal conditioning or analog-to-digital conversion can accommodate the 0–5 V output range
- Power supply infrastructure supports 9–32 V operation
- Operating temperature range of –20°C to 80°C satisfies application requirements
- Maximum pressure exposure does not exceed 300 PSI
- Current RoHS3 compliance is required for regulatory or procurement standards
Both parts are classified as obsolete. The IPSU-GP150-6 offers superior accuracy (±0.25% versus ±1%) and current regulatory compliance status.
Frequently Asked Questions (FAQ)
Q: Can the IPSU-GP150-6 directly replace the ST150PG2BPCF without circuit modifications?
A: Direct replacement is not possible without signal conditioning modifications. The output voltage ranges differ (0–5 V versus 0.5–4.5 V), and the supply voltage requirements differ (9–32 V versus 5 V). System electronics must be evaluated and adjusted accordingly.
Q: What is the impact of the different output voltage ranges?
A: The ST150PG2BPCF outputs 0.5–4.5 V across 0–150 PSI, while the IPSU-GP150-6 outputs 0–5 V across the same pressure range. Analog-to-digital converters, signal conditioning circuits, or calibration tables must be reconfigured to correctly interpret pressure values from the substitute part.
Q: Is the narrower operating temperature range of the IPSU-GP150-6 a limitation?
A: The IPSU-GP150-6 operates from –20°C to 80°C, compared to the ST150PG2BPCF range of –40°C to 100°C. If the application requires operation below –20°C or above 80°C, the IPSU-GP150-6 is not suitable. Verify actual system temperature exposure before selection.
Q: Why does the IPSU-GP150-6 have a lower maximum pressure rating?
A: The IPSU-GP150-6 maximum pressure is 300 PSI versus 450 PSI for the ST150PG2BPCF. This difference reflects different sensor design specifications. If system overpressure conditions may exceed 300 PSI, the IPSU-GP150-6 does not provide equivalent protection.
Q: Are both parts suitable for industrial automation applications?
A: Both parts are specified for industrial automation. However, both are classified as obsolete products. For new system designs, consult current product lines from Honeywell and Sensata-Cynergy3 to identify non-obsolete alternatives with extended availability and support.
Q: What is the significance of RoHS3 compliance on the IPSU-GP150-6?
A: RoHS3 compliance indicates the IPSU-GP150-6 meets current European Union Restriction of Hazardous Substances regulations. The ST150PG2BPCF carries RoHS compliance status, which may reflect an earlier regulatory framework. For procurement requiring current compliance certification, the IPSU-GP150-6 is the appropriate selection.
Q: Can the IPSU-GP150-6 be used in applications requiring the full –40°C to 100°C temperature range?
A: No. The IPSU-GP150-6 is rated only to –20°C to 80°C. Applications requiring the full extended temperature range of the ST150PG2BPCF require alternative components or the original part if procurement is possible.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts