SSR10HS-05495 Common Mode Choke Equivalent & Substitute Parts

Part Overview

The SSR10HS-05495 is a 2-line common mode choke manufactured by KEMET, rated for 49.5 mH inductance at 10 kHz with 500 mA maximum current capacity. This through-hole component operates across a temperature range of -25°C to 120°C and features 250V AC voltage rating with 1.6 Ohm maximum DC resistance. The part is ROHS3 compliant and currently active in production with 871 pieces in stock.

Equivalent and substitute parts are necessary when the primary component becomes unavailable, when design modifications require different electrical characteristics within the same functional category, or when alternative mechanical configurations better suit specific application requirements while maintaining core performance parameters.

Substiute Parts

SSR10HS-05495
KEMETIn Stock: 965SSR10HS-05495 Datasheet
SSR10HS-05495
Current Part
SSHB10H-05212
KEMETIn Stock: 880SSHB10H-05212 Datasheet
SSHB10H-05212
Parametric Equivalent
SSHB10H-R05500
KEMETIn Stock: 1305SSHB10H-R05500 Datasheet
SSHB10H-R05500
Parametric Equivalent
SSHB10H-R06400
KEMETIn Stock: 1017SSHB10H-R06400 Datasheet
SSHB10H-R06400
Parametric Equivalent
SSHB10HS-05177
KEMETIn Stock: 1213SSHB10HS-05177 Datasheet
SSHB10HS-05177
Parametric Equivalent
SSHB10HS-R05415
KEMETIn Stock: 1321SSHB10HS-R05415 Datasheet
SSHB10HS-R05415
Parametric Equivalent
SSHB21H-06400
KEMETIn Stock: 1169SSHB21H-06400 Datasheet
SSHB21H-06400
Parametric Equivalent
SSHB21H-R06825
KEMETIn Stock: 924SSHB21H-R06825 Datasheet
SSHB21H-R06825
Parametric Equivalent
SSHB21HS-05440
KEMETIn Stock: 1207SSHB21HS-05440 Datasheet
SSHB21HS-05440
Parametric Equivalent
SSHB21HS-06378
KEMETIn Stock: 938SSHB21HS-06378 Datasheet
SSHB21HS-06378
Parametric Equivalent
SSHB21HS-R05910
KEMETIn Stock: 864SSHB21HS-R05910 Datasheet
SSHB21HS-R05910
Parametric Equivalent
SSHB21HS-R06780
KEMETIn Stock: 879SSHB21HS-R06780 Datasheet
SSHB21HS-R06780
Parametric Equivalent
SSR10H-05595
KEMETIn Stock: 1232SSR10H-05595 Datasheet
SSR10H-05595
Parametric Equivalent
SSR10H-06475
KEMETIn Stock: 1124SSR10H-06475 Datasheet
SSR10H-06475
Parametric Equivalent
SSR10V-05595
KEMETIn Stock: 1021SSR10V-05595 Datasheet
SSR10V-05595
Parametric Equivalent
SSR10V-06475
KEMETIn Stock: 744SSR10V-06475 Datasheet
SSR10V-06475
Parametric Equivalent
SSR10VS-05495
KEMETIn Stock: 1420SSR10VS-05495 Datasheet
SSR10VS-05495
Parametric Equivalent
SSR21NH-M051350
KEMETIn Stock: 824SSR21NH-M051350 Datasheet
SSR21NH-M051350
Parametric Equivalent
SSR21NH-M061200
KEMETIn Stock: 1264SSR21NH-M061200 Datasheet
SSR21NH-M061200
Parametric Equivalent
SSR21NHS-M06890
KEMETIn Stock: 1092SSR21NHS-M06890 Datasheet
SSR21NHS-M06890
Parametric Equivalent
SSR21NV-M051350
KEMETIn Stock: 1175SSR21NV-M051350 Datasheet
SSR21NV-M051350
Parametric Equivalent
SSR21NVS-M06890
KEMETIn Stock: 1118SSR21NVS-M06890 Datasheet
SSR21NVS-M06890
Parametric Equivalent
SSRH7H-M05408
KEMETIn Stock: 1664SSRH7H-M05408 Datasheet
SSRH7H-M05408
Parametric Equivalent

Key Parameters

Parameter Value Unit
Inductance @ 10 kHz 49.5 mH
Current Rating (Max) 500 mA
DC Resistance (Max) 1.6 Ohm
Voltage Rating - AC 250 V
Operating Temperature Range -25 to 120 °C
Number of Lines 2 Lines
Mounting Type Through Hole
Package / Case Vertical, 4 PC Pin
Height (Max) 0.531 inches (13.50 mm)

Substitute Part Grouping Explanation

Substitution of the SSR10HS-05495 is determined by the following critical parameters:

Primary Substitution Criteria:

  • Number of Lines: 2 (fixed requirement)
  • Mounting Type: Through Hole (fixed requirement)
  • Package Configuration: Vertical, 4 PC Pin (fixed requirement)
  • Voltage Rating - AC: 250V (minimum acceptable)
  • Operating Temperature Range: Must support -25°C to 120°C minimum

Secondary Electrical Parameters (Allowable Variation):

  • Inductance @ 10 kHz: 49.5 mH nominal (substitutes range from 17.7 mH to 91 mH)
  • Current Rating (Max): 500 mA nominal (substitutes range from 500 mA to 600 mA)
  • DC Resistance (Max): 1.6 Ohm nominal (substitutes range from 1.3 Ohm to 1.88 Ohm)

Mechanical Parameters (Allowable Variation):

  • Height: 0.531 inches nominal (substitutes range from 0.531 inches to 0.610 inches)
  • Physical dimensions vary by series (SSHB10H, SSHB10HS, SSHB21H, SSHB21HS)

All substitute parts listed maintain ROHS3 compliance, REACH unaffected status, and active product status. Substitution is valid when the application requirements fall within the electrical and thermal specifications of the substitute part.

Parameter Comparison

Part Number Series Inductance @ 10 kHz (mH) Current Rating (mA) DCR Max (Ohm) Temp Range (°C) Height (inches / mm) Inventory (Pcs)
SSR10HS-05495 SSR 49.5 500 1.6 -25 to 120 0.531 / 13.50 871
SSHB10H-05212 SSHB10H 21.2 500 1.7 -25 to 130 0.610 / 15.50 859
SSHB10H-R05500 SSHB10H 50 500 1.7 -25 to 120 0.610 / 15.50 1219
SSHB10H-R06400 SSHB10H 40 600 1.3 -25 to 120 0.610 / 15.50 954
SSHB10HS-05177 SSHB10HS 17.7 500 1.55 -25 to 120 0.610 / 15.50 1169
SSHB10HS-R05415 SSHB10HS 41.5 500 1.55 -25 to 120 0.610 / 15.50 1296
SSHB21H-06400 SSHB21H 40 600 1.5 -25 to 120 0.610 / 15.50 1138
SSHB21H-R06825 SSHB21H 82.5 600 1.5 -25 to 120 0.610 / 15.50 901
SSHB21HS-05440 SSHB21HS 44 500 1.88 -25 to 120 0.610 / 15.50 1134
SSHB21HS-06378 SSHB21HS 37.8 600 1.48 -25 to 120 0.610 / 15.50 854
SSHB21HS-R05910 SSHB21HS 91 500 1.88 -25 to 120 0.610 / 15.50 824

Engineering Selection Recommendations

Closest Electrical Match: SSHB10H-R05500 provides the nearest inductance value (50 mH versus 49.5 mH nominal) with identical 500 mA current rating and 250V AC voltage specification. This part maintains full ROHS3 compliance and active product status. Height increases from 0.531 inches to 0.610 inches, requiring PCB layout verification.

For Higher Current Applications (600 mA): SSHB10H-R06400 and SSHB21HS-06378 both support 600 mA operation with acceptable inductance ranges (40 mH and 37.8 mH respectively). Both maintain 250V AC rating and -25°C to 120°C operating range. SSHB10H-R06400 offers lower DCR (1.3 Ohm) compared to the original 1.6 Ohm specification.

For Extended Temperature Range: SSHB10H-05212 extends the upper operating temperature to 130°C while maintaining 500 mA current rating. Inductance reduces to 21.2 mH, suitable for applications requiring lower inductance with enhanced thermal performance.

For Higher Inductance Requirements: SSHB21H-R06825 and SSHB21HS-R05910 provide inductance values of 82.5 mH and 91 mH respectively, supporting applications requiring increased filtering at the cost of larger physical dimensions and higher DCR values.

All recommended substitutes maintain ROHS3 compliance, REACH unaffected status, and active manufacturing status. Selection depends on specific application requirements for inductance, current capacity, and physical constraints.

Frequently Asked Questions (FAQ)

Q: Can SSHB10H-R05500 directly replace SSR10HS-05495 in my circuit?

A: SSHB10H-R05500 is electrically compatible with inductance of 50 mH (versus 49.5 mH), identical 500 mA current rating, and matching 250V AC voltage specification. The primary difference is increased height from 0.531 inches to 0.610 inches. PCB layout must accommodate the larger vertical dimension. Both parts operate across -25°C to 120°C and maintain ROHS3 compliance.

Q: What is the difference between SSHB10H and SSHB10HS series?

A: Both series are 2-line through-hole common mode chokes with identical mounting configuration. The SSHB10HS series typically features lower DCR values (1.55 Ohm maximum) compared to SSHB10H series (1.7 Ohm maximum), resulting in reduced power dissipation. Physical dimensions remain consistent at 0.866 inches L x 0.669 inches W x 0.610 inches H.

Q: Can I use a 600 mA rated part in place of a 500 mA rated part?

A: Yes. A higher current rating indicates the component can safely handle greater current without exceeding thermal or electrical limits. SSHB10H-R06400 (600 mA) and SSHB21HS-06378 (600 mA) are suitable replacements for 500 mA applications. Verify that inductance and DCR values meet circuit requirements.

Q: How do I select between SSHB21H and SSHB10H series?

A: SSHB21H series components feature larger physical dimensions (1.024 inches L x 0.906 inches W) compared to SSHB10H series (0.866 inches L x 0.669 inches W). Selection depends on available PCB space and inductance requirements. Both series maintain identical height (0.610 inches) and mounting configuration.

Q: Are all listed substitutes ROHS3 compliant?

A: Yes. All substitute parts listed maintain ROHS3 compliance and REACH unaffected status, matching the compliance profile of SSR10HS-05495. All parts are active in production with current inventory availability.

Q: What does DCR (DC Resistance) affect in my application?

A: DC Resistance determines power dissipation at rated current. Lower DCR values reduce heat generation. SSR10HS-05495 specifies 1.6 Ohm maximum DCR. SSHB10H-R06400 offers 1.3 Ohm (lower dissipation), while SSHB21HS-R05910 specifies 1.88 Ohm (higher dissipation). Select based on thermal budget and power efficiency requirements.

Q: Can I use SSHB21HS-R05910 (91 mH) instead of SSR10HS-05495 (49.5 mH)?

A: SSHB21HS-R05910 provides nearly double the inductance with identical 500 mA current rating and 250V AC voltage. This substitution is valid only if your circuit design requires higher inductance filtering. Verify that the larger physical dimensions (1.024 inches L x 0.906 inches W) fit your PCB layout. Higher DCR (1.88 Ohm) increases power dissipation.

Request Quote (Ships tomorrow)