SS11VL-30006 Common Mode Choke Equivalent & Substitute Parts

Part Overview

The SS11VL-30006 is a 600 µH Common Mode Choke (CMC) manufactured by KEMET, designed for power line filtering applications. This through-hole component features a 2-line configuration with a maximum current rating of 3A and operates across a temperature range of -25°C to 120°C. The part is currently in active production status with ROHS3 compliance and REACH unaffected designation. Substitute parts are identified when equivalent electrical and mechanical parameters align with application requirements, enabling component selection flexibility for procurement, inventory management, or design optimization purposes.

Substiute Parts

SS11VL-30006
KEMETIn Stock: 1167SS11VL-30006 Datasheet
SS11VL-30006
Current Part
SS21V-R300013
KEMETIn Stock: 1602SS21V-R300013 Datasheet
SS21V-R300013
Parametric Equivalent

Key Parameters

Parameter Value
Manufacturer Part Number SS11VL-30006
Manufacturer KEMET
Series SS
Product Category Common Mode Choke (CMC)
Filter Type Power Line
Number of Lines 2
Inductance @ Frequency 600 µH @ 1 kHz
Current Rating (Max) 3A
DC Resistance (DCR) (Max) 60 mOhm
Voltage Rating - AC 250V
Operating Temperature Range -25°C to 120°C
Mounting Type Through Hole
Package / Case Vertical, 4 PC Pin
Product Status Active
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the SS11VL-30006 is determined by the following critical parameters:

Mandatory Matching Criteria:

  • Manufacturer: KEMET
  • Series: SS
  • Filter Type: Power Line
  • Number of Lines: 2
  • Current Rating (Max): 3A
  • Mounting Type: Through Hole
  • Package / Case: Vertical, 4 PC Pin
  • Voltage Rating - AC: 250V
  • Operating Temperature Range: -25°C to 120°C
  • RoHS Status: ROHS3 Compliant

Allowable Variation Parameters:

  • Inductance @ Frequency: Different inductance values are permitted when application requirements specify alternative filtering characteristics
  • DC Resistance (DCR) (Max): Variation within acceptable limits based on circuit design specifications
  • Physical Dimensions: Minor dimensional differences are acceptable provided mounting compatibility is maintained

The substitute part SS21V-R300013 satisfies all mandatory matching criteria while providing an alternative inductance value of 1.3 mH @ 1 kHz with a maximum DCR of 70 mOhm.

Parameter Comparison

Parameter SS11VL-30006 SS21V-R300013
Manufacturer KEMET KEMET
Series SS SS
Filter Type Power Line Power Line
Number of Lines 2 2
Inductance @ Frequency 600 µH @ 1 kHz 1.3 mH @ 1 kHz
Current Rating (Max) 3A 3A
DC Resistance (DCR) (Max) 60 mOhm 70 mOhm
Voltage Rating - AC 250V 250V
Operating Temperature Range -25°C to 120°C -25°C to 120°C
Mounting Type Through Hole Through Hole
Package / Case Vertical, 4 PC Pin Vertical, 4 PC Pin
Product Status Active Active
RoHS Status ROHS3 Compliant ROHS3 Compliant
Size / Dimension (L x W) 22.00 mm x 14.50 mm 20.50 mm x 16.50 mm
Height (Max) 19.50 mm 24.50 mm

Engineering Selection Recommendations

Both SS11VL-30006 and SS21V-R300013 maintain active product status with ROHS3 compliance and REACH unaffected designation, ensuring regulatory alignment for current and future applications. Selection between these components is determined by inductance requirements specific to the circuit design. The SS11VL-30006 provides 600 µH inductance with 60 mOhm maximum DCR, while the SS21V-R300013 provides 1.3 mH inductance with 70 mOhm maximum DCR. Both components support identical current ratings (3A), voltage specifications (250V AC), and operating temperature ranges (-25°C to 120°C). Physical dimensions differ; the SS21V-R300013 exhibits greater height (24.50 mm versus 19.50 mm), which must be verified against available PCB mounting space. Component selection shall be based on circuit filtering specifications and available board real estate.

Frequently Asked Questions (FAQ)

Q: Can SS21V-R300013 be used as a direct replacement for SS11VL-30006?

A: Direct replacement is possible only if the circuit design specifies an inductance value of 1.3 mH @ 1 kHz. The higher inductance value of SS21V-R300013 alters the filtering characteristics compared to the 600 µH specification of SS11VL-30006. Verify circuit requirements before substitution.

Q: What is the difference in DC resistance between these components?

A: SS11VL-30006 specifies a maximum DCR of 60 mOhm, while SS21V-R300013 specifies a maximum DCR of 70 mOhm. This 10 mOhm difference may impact power dissipation calculations in high-current applications.

Q: Are there physical mounting constraints when substituting between these parts?

A: Yes. SS21V-R300013 has a maximum height of 24.50 mm compared to 19.50 mm for SS11VL-30006. Verify that available PCB mounting clearance accommodates the taller component before substitution.

Q: Do both components meet the same regulatory requirements?

A: Yes. Both SS11VL-30006 and SS21V-R300013 are ROHS3 compliant and REACH unaffected, meeting equivalent regulatory standards.

Q: What determines whether these parts are substitutable?

A: Substitutability is determined by matching manufacturer (KEMET), series (SS), filter type (Power Line), line configuration (2-line), current rating (3A), mounting type (Through Hole), package style (Vertical, 4 PC Pin), AC voltage rating (250V), and operating temperature range (-25°C to 120°C). Inductance and DCR values may vary based on circuit specifications.

Q: Can these components be used interchangeably in all power line filtering applications?

A: No. The inductance values differ significantly (600 µH versus 1.3 mH). Application-specific filtering requirements determine which inductance value is appropriate. Circuit analysis is required to confirm compatibility.

Request Quote (Ships tomorrow)