Part Overview
The SPB03B-12 from MEAN WELL USA Inc. is an isolated DC-DC converter module, providing a single 12V output at up to 250mA from an 18V to 36V input range, with a power rating of 3W. It includes features such as remote on/off, overcurrent protection (OCP), and short circuit protection (SCP). The part is packaged in an 8-SIP module with 7 leads, suitable for through-hole mounting, and operates in harsh environments with an operating temperature range of -40°C to 85°C (with derating). The product status is listed as obsolete, making it essential to identify equivalent parts to support ongoing designs, maintenance, and production continuity.
Substiute Parts
Key Parameters
| Parameter | SPB03B-12 |
|---|---|
| Voltage - Input (Min) | 18V |
| Voltage - Input (Max) | 36V |
| Voltage - Output 1 | 12V |
| Current - Output (Max) | 250mA |
| Power (Watts) | 3 W |
| Voltage - Isolation | 1 kV |
| Number of Outputs | 1 |
| Type | Isolated Module |
| Features | Remote On/Off, OCP, SCP |
| Operating Temperature | -40°C ~ 85°C (With Derating) |
| Efficiency | 80% |
| Mounting Type | Through Hole |
| Package / Case | 8-SIP Module, 7 Leads |
| Size / Dimension | 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) |
| Control Features | Enable, Active Low |
| Applications | ITE (Commercial) |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute part selection for the SPB03B-12 isolated module DC-DC converter is determined strictly by matching the following key electrical and mechanical parameters: input voltage range (18V–36V), single output voltage of 12V, maximum output current of 250mA, total output power of 3W, voltage isolation of 1kV, module type (isolated), feature set (remote on/off, OCP, SCP), form factor and mounting type (8-SIP, through hole), and regulatory compliance. Only parts that meet these criteria are included as substitutes.
Parameter Comparison
| Parameter | SPB03B-12 (MEAN WELL USA Inc.) | RS3-2412S (Recom Power) |
|---|---|---|
| Voltage - Input (Min) | 18V | 18V |
| Voltage - Input (Max) | 36V | 36V |
| Voltage - Output 1 | 12V | 12V |
| Current - Output (Max) | 250mA | 250mA |
| Power (Watts) | 3 W | 3 W |
| Voltage - Isolation | 1 kV | 1 kV |
| Number of Outputs | 1 | 1 |
| Type | Isolated Module | Isolated Module |
| Features | Remote On/Off, OCP, SCP | Remote On/Off, SCP |
| Operating Temperature | -40°C ~ 85°C (With Derating) | -40°C ~ 71°C |
| Efficiency | 80% | 83% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 8-SIP Module, 7 Leads | 8-SIP Module, 7 Leads |
| Size / Dimension | 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) | 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) |
| Control Features | Enable, Active Low | Enable, Active Low |
| Applications | ITE (Commercial) | ITE (Commercial) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| REACH Status | REACH Unaffected | REACH Unaffected |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
Due to the obsolete status of the SPB03B-12, selection of a substitute part is necessary for continued design availability and manufacturing support. The RS3-2412S from Recom Power matches the critical electrical, mechanical, and regulatory compliance parameters listed for the SPB03B-12, including input/output voltages, output current, isolation, size, package type, RoHS and REACH compliance, MSL rating, ECCN, and HTSUS. The RS3-2412S is classified as an active product and is available in inventory. Substitution should be based strictly on these matched parameters and product status.
Frequently Asked Questions (FAQ)
Q1: Which parameters must be matched for a valid DC-DC converter substitute in the isolated module category?
A1: The substitute must match input voltage range, output voltage and current, power rating, isolation voltage, number of outputs, form factor, mounting type, package/case, features, operating temperature range, control features, regulatory compliance (RoHS, REACH), moisture sensitivity level, ECCN, and HTSUS.
Q2: Does the RS3-2412S fit the same PCB footprint and mounting requirements as the SPB03B-12?
A2: Both models share the 8-SIP module, 7 leads, through-hole mounting, and identical dimensions, supporting direct replacement in compatible socketed designs without physical modification, based on provided parameters.
Q3: Are all protection and control features identical between SPB03B-12 and RS3-2412S?
A3: Both include remote on/off and SCP (short circuit protection); SPB03B-12 additionally specifies OCP (overcurrent protection). Refer directly to key feature parameters for precise compatibility.
Q4: Are there any differences in operating temperature that affect substitution?
A4: The SPB03B-12 operates from -40°C to 85°C (with derating); RS3-2412S operates from -40°C to 71°C. This difference may affect suitability depending on the required operating conditions of the application, as per the stated ranges.
Q5: Is regulatory compliance equivalent between the two part numbers?
A5: Both the SPB03B-12 and RS3-2412S are listed as ROHS3 compliant, REACH unaffected, and have matching ECCN and HTSUS codes per provided data.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts