SPA02C-12 Equivalent & Substitute Parts Reference

Part Overview

The MEAN WELL USA Inc. SPA02C-12 is an isolated module DC DC converter, offering a single 12V output at 167mA from a 36V-72V input, with a 2W power rating. This device is categorized as obsolete, making it necessary for engineers to identify suitable alternatives for current and future designs or repairs. Substitution requires strict adherence to electrical and mechanical equivalence as defined by the provided parameters.

Substiute Parts

SPA02C-12
MEAN WELL USA Inc.In Stock: 787SPA02C-12 Datasheet
SPA02C-12
Current Part
SPAN02C-12
MEAN WELL USA Inc.In Stock: 771SPAN02C-12 Datasheet
SPAN02C-12
Direct
RS-4812S/H3
Recom PowerIn Stock: 12210RS-4812S/H3 Datasheet
RS-4812S/H3
Similar

Key Parameters

Parameter Value
Manufacturer Part Number SPA02C-12
Type Isolated Module
Number of Outputs 1
Voltage - Input (Min) 36V
Voltage - Input (Max) 72V
Voltage - Output 1 12V
Current - Output (Max) 167mA
Power (Watts) 2 W
Voltage - Isolation 1 kV
Applications ITE (Commercial)
Features Remote On/Off, OCP, SCP
Operating Temperature -40°C ~ 85°C (With Derating)
Efficiency 82%
Mounting Type Through Hole
Package / Case 8-SIP Module, 7 Leads
Size / Dimension 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm)
RoHS Status ROHS3 Compliant
MSL 1 (Unlimited)
REACH Status REACH Unaffected
Product Status Obsolete

Substitute Part Grouping Explanation

Substitutes for the SPA02C-12 are determined strictly by matching or exceeding the following parameters: number of outputs, input voltage range, output voltage, output current, power rating, isolation voltage, efficiency, package/case, mounting type, compliance certifications (RoHS, REACH), and application suitability as specified. Only parts meeting or exceeding these criteria are listed.

Parameter Comparison

Parameter SPA02C-12
(Main)
SPAN02C-12
(Direct Substitute)
RS-4812S/H3
(Similar)
Manufacturer MEAN WELL USA Inc. MEAN WELL USA Inc. Recom Power
Type Isolated Module Isolated Module Isolated Module
Number of Outputs 1 1 1
Voltage - Input (Min) 36V 36V 36V
Voltage - Input (Max) 72V 75V 72V
Voltage - Output 1 12V 12V 12V
Current - Output (Max) 167mA 167mA 166mA
Power (Watts) 2 W 2 W 2 W
Voltage - Isolation 1 kV 1.5 kV 3 kV
Applications ITE (Commercial) ITE (Commercial) ITE (Commercial), Medical
Features Remote On/Off, OCP, SCP Remote On/Off, OCP, SCP, UVLO Remote On/Off, SCP
Operating Temperature -40°C ~ 85°C (With Derating) -40°C ~ 90°C (With Derating) -40°C ~ 85°C
Efficiency 82% 82% 83%
Mounting Type Through Hole Through Hole Through Hole
Package / Case 8-SIP Module, 7 Leads 8-SIP Module, 7 Leads 8-SIP Module, 7 Leads
Size / Dimension 0.86" x 0.36" x 0.44" 0.86" x 0.36" x 0.44" 0.86" x 0.36" x 0.44"
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
MSL 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected REACH Unaffected
Product Status Obsolete Active Active

Engineering Selection Recommendations

Based strictly on product status and provided compliance fields, SPA02C-12 is classified as obsolete. Both SPAN02C-12 and RS-4812S/H3 are listed as active and possess ROHS3 compliance and REACH unaffected status. All parts are MSL 1 (Unlimited). Only parts marked as active and compliant per these criteria should be selected to maintain supply continuity and regulatory adherence.

Frequently Asked Questions (FAQ)

Q1: What defines a suitable substitute for the SPA02C-12?
A1: A suitable substitute must match or exceed all key electrical, mechanical, and compliance parameters provided: same number of outputs, input voltage range, output voltage, output current, power rating, isolation voltage, application suitability, mounting type, package/case, and compliance certifications.

Q2: Are the physical dimensions and mounting of the substitutes compatible?
A2: All listed substitutes utilize the 8-SIP Module, 7 Leads package and possess identical physical dimensions, ensuring compatibility in layout and mechanical fit.

Q3: Do substitute models maintain the same safety and environmental certifications?
A3: All models are ROHS3 compliant, REACH unaffected, and have MSL 1 (Unlimited); there are no variances in compliance status among listed options.

Q4: Does the higher isolation voltage in substitutes affect compatibility?
A4: Substitutes with higher isolation voltage than the original maintain compatibility for applications requiring at least the main part’s isolation level.

Q5: Why is substitution necessary for the SPA02C-12?
A5: Substitution is required because the SPA02C-12 is obsolete, and active alternatives are needed for guaranteed long-term supply and ongoing compliance.

Request Quote (Ships tomorrow)