SP690ACP-L Equivalent & Substitute Parts

Part Overview

The SP690ACP-L is a single-channel power supply supervisor IC manufactured by MaxLinear, Inc., housed in an 8-DIP package. This device monitors a single voltage threshold at 4.65V and provides active-low reset output with a 140ms minimum reset timeout. The SP690ACP-L is classified as obsolete, making equivalent and substitute parts necessary for ongoing system support and new designs requiring supervisor functionality.

Substiute Parts

SP690ACP-L
MaxLinear, Inc.In Stock: 1214SP690ACP-L Datasheet
SP690ACP-L
Current Part
ADM690AANZ
Analog Devices Inc.In Stock: 1443ADM690AANZ Datasheet
ADM690AANZ
MFR Recommended
ADM690ANZ
Analog Devices Inc.In Stock: 2553ADM690ANZ Datasheet
ADM690ANZ
MFR Recommended
ADM694ANZ
Analog Devices Inc.In Stock: 1239ADM694ANZ Datasheet
ADM694ANZ
MFR Recommended
LTC690CN8#PBF
Analog Devices Inc.In Stock: 2235LTC690CN8#PBF Datasheet
LTC690CN8#PBF
MFR Recommended
LTC690IN8#PBF
Analog Devices Inc.In Stock: 3345LTC690IN8#PBF Datasheet
LTC690IN8#PBF
MFR Recommended
MAX690ACPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 3689MAX690ACPA+ Datasheet
MAX690ACPA+
MFR Recommended
MAX690AEPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 4186MAX690AEPA+ Datasheet
MAX690AEPA+
MFR Recommended
MAX690CPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 4363MAX690CPA+ Datasheet
MAX690CPA+
MFR Recommended
MAX690EPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 3328MAX690EPA+ Datasheet
MAX690EPA+
MFR Recommended
MAX694CPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 1972MAX694CPA+ Datasheet
MAX694CPA+
MFR Recommended
MAX694EPA+
Analog Devices Inc./Maxim IntegratedIn Stock: 2436MAX694EPA+ Datasheet
MAX694EPA+
MFR Recommended

Key Parameters

Parameter SP690ACP-L
Manufacturer MaxLinear, Inc.
Category Power Management (PMIC)
Package / Case 8-DIP (0.300", 7.62mm)
Mounting Type Through Hole
Type Simple Reset/Power-On Reset
Number of Voltages Monitored 1
Voltage - Threshold 4.65V
Reset Active Low
Reset Timeout 140ms Minimum
Operating Temperature 0°C ~ 70°C (TA)
Product Status Obsolete
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution for the SP690ACP-L is determined by the following critical parameters:

  • Package compatibility: 8-DIP (0.300", 7.62mm) through-hole mounting
  • Voltage threshold: 4.65V single-channel monitoring
  • Reset polarity: Active Low
  • Reset timeout: 140ms minimum
  • Output type: Determines functional compatibility

Substitute parts are grouped into two categories based on output configuration:

Category 1: Push-Pull/Totem Pole Output — ADM690AANZ, ADM694ANZ, MAX690ACPA+, MAX690AEPA+, MAX690CPA+, MAX690EPA+, MAX694CPA+ — These parts provide push-pull output suitable for direct microprocessor reset inputs.

Category 2: Open Drain/Open Collector Output — LTC690CN8#PBF, LTC690IN8#PBF — These parts require external pull-up resistors and are suitable for applications requiring open-drain reset signaling.

Parameter Comparison

Part Number Manufacturer Output Type Reset Timeout Operating Temperature Product Status RoHS Status
SP690ACP-L MaxLinear, Inc. 140ms Minimum 0°C ~ 70°C Obsolete
ADM690AANZ Analog Devices Inc. Push-Pull, Totem Pole 140ms Minimum -40°C ~ 85°C Active ROHS3 Compliant
ADM690ANZ Analog Devices Inc. Push-Pull, Totem Pole 35ms Minimum -40°C ~ 85°C Active ROHS3 Compliant
ADM694ANZ Analog Devices Inc. Push-Pull, Totem Pole 140ms Minimum -40°C ~ 85°C Active ROHS3 Compliant
LTC690CN8#PBF Analog Devices Inc. Open Drain or Open Collector 35ms Minimum 0°C ~ 70°C Active ROHS3 Compliant
LTC690IN8#PBF Analog Devices Inc. Open Drain or Open Collector 35ms Minimum -40°C ~ 85°C Active ROHS3 Compliant
MAX690ACPA+ Analog Devices Inc./Maxim Integrated Push-Pull, Totem Pole 140ms Minimum 0°C ~ 70°C Active ROHS3 Compliant
MAX690AEPA+ Analog Devices Inc./Maxim Integrated Push-Pull, Totem Pole 140ms Minimum -40°C ~ 85°C Active ROHS3 Compliant
MAX690CPA+ Analog Devices Inc./Maxim Integrated Push-Pull, Totem Pole 35ms Minimum 0°C ~ 70°C Active ROHS3 Compliant
MAX690EPA+ Analog Devices Inc./Maxim Integrated Push-Pull, Totem Pole 35ms Minimum -40°C ~ 85°C Active ROHS3 Compliant
MAX694CPA+ Analog Devices Inc./Maxim Integrated Push-Pull, Totem Pole 140ms Minimum 0°C ~ 70°C Active ROHS3 Compliant

Engineering Selection Recommendations

Direct Replacement (140ms Reset Timeout, Push-Pull Output, 0°C ~ 70°C): MAX690ACPA+ and MAX694CPA+ are pin-compatible direct replacements for the SP690ACP-L with identical reset timeout specifications and operating temperature range. Both are active products with ROHS3 compliance.

Extended Temperature Range (140ms Reset Timeout, Push-Pull Output, -40°C ~ 85°C): ADM690AANZ and ADM694ANZ provide the same 140ms reset timeout with extended operating temperature coverage. These are suitable for applications requiring wider temperature operation while maintaining functional equivalence.

Faster Reset Timeout (35ms Reset Timeout, Push-Pull Output): MAX690CPA+, MAX690EPA+, and ADM690ANZ offer reduced reset timeout specifications. These are applicable only when system design permits faster reset assertion and the 35ms timeout meets application requirements.

Open Drain Output (35ms Reset Timeout): LTC690CN8#PBF and LTC690IN8#PBF provide open-drain output requiring external pull-up resistors. These are suitable for applications with open-drain reset bus architectures. LTC690IN8#PBF extends temperature range to -40°C ~ 85°C.

All substitute parts are active products with ROHS3 compliance and REACH unaffected status, ensuring regulatory compliance for new designs.

Frequently Asked Questions (FAQ)

Q: Can I use a substitute part with a different reset timeout? A: Reset timeout substitution depends on system design. The SP690ACP-L specifies 140ms minimum. Parts with 35ms timeout (ADM690ANZ, MAX690CPA+, MAX690EPA+, LTC690CN8#PBF, LTC690IN8#PBF) provide faster reset assertion. Verify that your application timing requirements accommodate the shorter timeout before substitution.

Q: What is the difference between push-pull and open-drain output? A: Push-pull output (ADM690AANZ, ADM694ANZ, MAX690ACPA+, MAX690AEPA+, MAX690CPA+, MAX690EPA+, MAX694CPA+) actively drives the reset signal high and low, suitable for direct microprocessor reset inputs. Open-drain output (LTC690CN8#PBF, LTC690IN8#PBF) requires an external pull-up resistor and is used in open-drain bus architectures.

Q: Are all substitute parts pin-compatible with the SP690ACP-L? A: All substitute parts use the 8-DIP (0.300", 7.62mm) package with through-hole mounting. Pin compatibility depends on output type and specific circuit design. Verify pinout against your schematic before substitution.

Q: Can I use a substitute part rated for -40°C ~ 85°C in a 0°C ~ 70°C application? A: Yes. Parts rated for -40°C ~ 85°C (ADM690AANZ, ADM694ANZ, LTC690IN8#PBF, MAX690AEPA+, MAX690EPA+) are suitable for narrower temperature ranges. The extended rating provides additional design margin and environmental robustness.

Q: What is the inventory status of substitute parts? A: All substitute parts are active products with current inventory availability ranging from 1,210 to 4,257 units in stock, ensuring supply continuity for production and replacement applications.

Request Quote (Ships tomorrow)