Part Overview
The SL1024B090RG is a Gas Discharge Tube (GDT) rated for 90V DC spark-over voltage with 20kA impulse discharge current capacity in a 3-pole through-hole configuration. This component is classified as obsolete, making substitute parts necessary for ongoing design support and procurement continuity. The SL1021B090RF serves as a direct functional equivalent with identical electrical specifications and mechanical compatibility.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Voltage - DC Spark Over (Nominal) | 90 V |
| Impulse Discharge Current (8/20µs) | 20000A (20kA) |
| Number of Poles | 3 |
| Fail Mode | Short |
| Mounting Type | Through Hole |
| Package / Case | Axial Cylinder, 3 Lead (Radial Bend) |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
The SL1021B090RF qualifies as a direct substitute for the SL1024B090RG based on matching electrical and mechanical parameters:
Matching Criteria:
- Voltage - DC Spark Over (Nominal): 90 V
- Impulse Discharge Current (8/20µs): 20000A (20kA)
- Number of Poles: 3
- Fail Mode: Short
- Mounting Type: Through Hole
- Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
- RoHS Status: ROHS3 Compliant
- Moisture Sensitivity Level (MSL): 1 (Unlimited)
Both components belong to the Littelfuse GDT product family and maintain identical functional specifications for surge protection applications requiring 90V protection with 20kA discharge capacity.
Parameter Comparison
| Parameter | SL1024B090RG (Main) | SL1021B090RF (Substitute) |
|---|---|---|
| Manufacturer | Littelfuse | Littelfuse Inc. |
| Series | SL1024B | SL1021B |
| Product Status | Obsolete | Active |
| Voltage - DC Spark Over (Nominal) | 90 V | 90 V |
| Impulse Discharge Current (8/20µs) | 20000A (20kA) | 20000A (20kA) |
| Number of Poles | 3 | 3 |
| Fail Mode | Short | Short |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | Axial Cylinder, 3 Lead (Radial Bend) | Axial Cylinder, 3 Lead (Radial Bend) |
| Packaging | - | Tray |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8536.30.8000 | 8536.30.8000 |
Engineering Selection Recommendations
The SL1021B090RF is the appropriate substitute for the obsolete SL1024B090RG. The substitute part maintains active product status with Littelfuse, ensuring long-term availability and supply chain continuity. Both components satisfy ROHS3 compliance requirements and carry identical electrical performance specifications for 90V surge protection applications with 20kA discharge capacity. The through-hole mounting configuration and axial cylinder package remain unchanged, supporting direct board-level compatibility. Selection of the SL1021B090RF eliminates obsolescence risk while preserving all functional and compliance characteristics of the original design.
Frequently Asked Questions (FAQ)
Q: Can the SL1021B090RF be used as a direct replacement for the SL1024B090RG?
A: Yes. Both components share identical electrical specifications (90V spark-over, 20kA impulse discharge current), mechanical configuration (3-pole through-hole, axial cylinder package), and compliance certifications (ROHS3). The SL1021B090RF is a direct functional equivalent.
Q: What is the primary difference between these two parts?
A: The SL1024B090RG is classified as obsolete, while the SL1021B090RF maintains active product status. The substitute part ensures ongoing availability and supply chain support. Packaging differs (unspecified for SL1024B090RG versus tray for SL1021B090RF), but electrical and mechanical performance are identical.
Q: Are there any compatibility concerns with board-level integration?
A: No. Both components use identical through-hole mounting with axial cylinder, 3-lead radial bend package configuration. PCB footprints and lead spacing remain unchanged, supporting direct substitution without design modification.
Q: Do both parts meet the same regulatory and compliance standards?
A: Yes. Both the SL1024B090RG and SL1021B090RF are ROHS3 compliant with MSL rating of 1 (unlimited moisture sensitivity). Both carry EAR99 export classification and HTSUS code 8536.30.8000.
Q: What is the impulse discharge current rating, and does it remain constant across both parts?
A: Both components are rated for 20000A (20kA) impulse discharge current at 8/20µs waveform, meeting identical surge protection requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts