Request Quote
(Ships tomorrow)
SFT01M-15 Equivalent & Substitute Parts Reference
Part Overview
The SFT01M-15 from MEAN WELL USA Inc. is a DC DC converter categorized as an Isolated Module. It delivers a single 15V output at 67mA with an input voltage range of 10.8V to 13.2V. The part features a 3 kV isolation, SCP and OCP safety features, operates in temperatures from -40°C to 85°C (with derating), and provides efficiency of 74%. SFT01M-15 has been marked as obsolete, creating a requirement for direct equivalents or substitute parts maintaining compatibility in critical applications where identical functional and mechanical characteristics must be met.
Substiute Parts
Key Parameters
| Parameter | SFT01M-15 |
|---|---|
| Output Voltage | 15V |
| Output Current (Max) | 67mA |
| Input Voltage Range | 10.8V – 13.2V |
| Power (Watts) | 1 W |
| Number of Outputs | 1 |
| Voltage Isolation | 3 kV |
| Features | OCP, SCP |
| Operating Temperature | -40°C ~ 85°C (With Derating) |
| Efficiency | 74% |
| Mounting Type | Surface Mount |
| Package / Case | 12-SMD Module, 10 Leads |
| Size / Dimension | 0.60" L x 0.30" W x 0.26" H (15.2mm x 7.5mm x 6.5mm) |
| Product Status | Obsolete |
| RoHS Status | ROHS3 Compliant |
| REACH Status | REACH Unaffected |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Suitable substitutes for DC DC converters are determined by ensuring convergence in voltage rating (input and output), output current, isolation voltage, power output, number of outputs, safety features (OCP, SCP), thermal operating range, efficiency, mounting type, and package/case dimensions. All listed parts must match or exceed these parameters to guarantee true electrical and mechanical interchangeability within the module’s category. Only parameters explicitly supplied are referenced as criteria for equivalency.
Parameter Comparison
| Parameter | SFT01M-15 MEAN WELL USA Inc. |
SFTN01M-15 MEAN WELL USA Inc. |
SB01S1215A Delta Electronics |
|---|---|---|---|
| Output Voltage | 15V | 15V | 15V |
| Output Current (Max) | 67mA | 67mA | 67mA |
| Input Voltage Range | 10.8V – 13.2V | 10.8V – 13.2V | 10.8V – 13.2V |
| Power (Watts) | 1 W | 1 W | 1 W |
| Number of Outputs | 1 | 1 | 1 |
| Voltage Isolation | 3 kV | - | 3 kV |
| Features | OCP, SCP | - | SCP |
| Operating Temperature | -40°C ~ 85°C (With Derating) | -40°C ~ 85°C (With Derating) | -40°C ~ 85°C |
| Efficiency | 74% | - | 80% |
| Mounting Type | Surface Mount | - | Surface Mount |
| Package / Case | 12-SMD Module, 10 Leads | - | 12-SMD Module, 10 Leads |
| Size / Dimension | 0.60" L x 0.30" W x 0.26" H (15.2mm x 7.5mm x 6.5mm) |
- | 0.60" L x 0.42" W x 0.28" H (15.2mm x 10.7mm x 7.0mm) |
| Product Status | Obsolete | - | Active |
| RoHS Status | ROHS3 Compliant | - | ROHS3 Compliant |
| REACH Status | REACH Unaffected | - | REACH Unaffected |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | - | 3 (168 Hours) |
Engineering Selection Recommendations
SFT01M-15 is obsolete. Substitute models SB01S1215A (Delta Electronics) and SFTN01M-15 (MEAN WELL USA Inc.) are listed as equivalents. SB01S1215A is active and meets RoHS3 and REACH compliance as specified. The Moisture Sensitivity Level differs, with the main part at MSL 1 (Unlimited) and the Delta replacement at MSL 3 (168 Hours).
Frequently Asked Questions (FAQ)
Q: What are the critical substitution criteria for SFT01M-15?
A: Output voltage, output current, input voltage range, power, isolation voltage, number of outputs, safety features, operating temperature, mounting type, and package/case.
Q: Are the physical package and dimensions compatible among substitutes?
A: SB01S1215A shares the same package type (12-SMD Module, 10 Leads) but size and thickness may vary; verify mechanical fit per listed values.
Q: Do all substitutes maintain necessary compliance?
A: Both SFT01M-15 and SB01S1215A are ROHS3 compliant and REACH unaffected. Check MSL requirements for assembly compatibility.
Q: Will the substitute provide equivalent isolation and performance?
A: SB01S1215A specifies 3 kV isolation, matching the SFT01M-15.
Q: What if SFTN01M-15 has missing parameter data?
A: Only listed parameters may be used. If not provided, compatibility cannot be determined based solely on the supplied information.
Q: Are all substitutes active and available?
A: SB01S1215A is listed as active; SFTN01M-15 status not specified. SFT01M-15 itself is obsolete.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts