SE98TK,118 Equivalent & Substitute Parts

Part Overview

The SE98TK,118 is a temperature monitoring system sensor manufactured by NXP USA Inc., designed for internal temperature sensing applications with I2C/SMBus output capability. This component operates across a -40°C to 125°C temperature range with ±4°C maximum accuracy and supports both alarm and fan control outputs. The part is currently classified as obsolete, making identification of functionally equivalent alternatives essential for ongoing system support and new design implementations.

Substiute Parts

SE98TK,118
NXP USA Inc.In Stock: 1154SE98TK,118 Datasheet
SE98TK,118
Current Part
SE98ATP,547
NXP SemiconductorsIn Stock: 40865SE98ATP,547 Datasheet
SE98ATP,547
MFR Recommended

Key Parameters

Parameter SE98TK,118
Manufacturer NXP USA Inc.
Category Power Management (PMIC)
Function Temp Monitoring System (Sensor)
Sensor Type Internal
Sensing Temperature Range -40°C ~ 125°C
Accuracy ±4°C (Max)
Output Type I2C/SMBus
Output Alarm Yes
Output Fan Yes
Supply Voltage 1.7V ~ 3.6V
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case 8-VFDFN Exposed Pad
Topology ADC (Sigma Delta), Register Bank
RoHS Status ROHS3 Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution eligibility for the SE98TK,118 is determined by the following critical parameters:

  • Identical sensor function (Temp Monitoring System with internal sensing)
  • Matching temperature sensing range (-40°C ~ 125°C)
  • Equivalent accuracy specification (±4°C maximum)
  • Identical output interface (I2C/SMBus protocol)
  • Presence of both alarm and fan control outputs
  • Compatible supply voltage range (1.7V ~ 3.6V)
  • Surface mount configuration
  • Equivalent or superior regulatory compliance (ROHS3, REACH Unaffected)

The SE98ATP,547 meets all substitution criteria as an active product from NXP Semiconductors within the same SE98 base product family, maintaining functional equivalence across all specified parameters.

Parameter Comparison

Parameter SE98TK,118 SE98ATP,547 Compatibility
Manufacturer NXP USA Inc. NXP Semiconductors Same manufacturer family
Function Temp Monitoring System (Sensor) Temp Monitoring System (Sensor) Identical
Sensor Type Internal Internal Identical
Sensing Temperature Range -40°C ~ 125°C -40°C ~ 125°C Identical
Accuracy ±4°C (Max) ±4°C (Max) Identical
Output Type I2C/SMBus I2C/SMBus Identical
Output Alarm Yes Yes Identical
Output Fan Yes Yes Identical
Supply Voltage 1.7V ~ 3.6V 1.7V ~ 3.6V Identical
Operating Temperature -40°C ~ 125°C -40°C ~ 125°C Identical
Mounting Type Surface Mount Surface Mount Identical
Topology ADC (Sigma Delta), Register Bank ADC (Sigma Delta), Register Bank Identical
Package / Case 8-VFDFN Exposed Pad 8-WFDFN Exposed Pad Functionally equivalent, different pin configuration
Supplier Device Package 8-HVSON (3x3) 8-HWSON (2x3) Different physical dimensions
RoHS Status ROHS3 Compliant ROHS3 Compliant Identical
Product Status Obsolete Active Substitute is actively manufactured

Engineering Selection Recommendations

The SE98ATP,547 is the qualified substitute for the obsolete SE98TK,118 based on the following engineering criteria:

Functional Equivalence: Both components share identical core specifications including temperature sensing range, accuracy, output protocol, and supply voltage requirements. The I2C/SMBus interface, alarm output, and fan control functionality are preserved.

Regulatory Compliance: Both parts maintain ROHS3 compliance and REACH unaffected status, ensuring compatibility with current environmental and regulatory requirements.

Active Product Status: The SE98ATP,547 is an active product with confirmed inventory availability (40,773 pieces), providing long-term supply assurance compared to the obsolete SE98TK,118.

Package Consideration: The substitute uses an 8-HWSON (2x3) package versus the original 8-HVSON (3x3) package. PCB layout modifications are required to accommodate the different physical dimensions and pin configuration. Schematic-level functionality remains unchanged.

Frequently Asked Questions (FAQ)

Q: Can SE98ATP,547 directly replace SE98TK,118 without PCB modifications?

A: No. While functionally equivalent at the schematic level, the package dimensions differ (8-HWSON 2x3 versus 8-HVSON 3x3). PCB footprint redesign is necessary. Pin functionality and electrical characteristics are compatible.

Q: Are the I2C/SMBus protocols identical between these parts?

A: Yes. Both components implement identical I2C/SMBus output protocols with matching alarm and fan control outputs. Software and firmware interfaces require no modification.

Q: What is the impact of different moisture sensitivity levels?

A: SE98TK,118 has MSL 1 (unlimited), while SE98ATP,547 has MSL 3 (168 hours). This affects storage and handling procedures. SE98ATP,547 requires controlled humidity storage and has a 168-hour floor life after moisture exposure.

Q: Is the temperature sensing accuracy maintained in the substitute?

A: Yes. Both parts specify ±4°C maximum accuracy across the identical -40°C to 125°C operating range.

Q: Why is SE98TK,118 classified as obsolete?

A: Product obsolescence is determined by manufacturer lifecycle decisions. The SE98ATP,547 represents the active continuation within the SE98 product family.

Q: Are there any supply voltage compatibility concerns?

A: No. Both components operate across the identical 1.7V to 3.6V supply voltage range with no modifications required to power delivery circuits.

Request Quote (Ships tomorrow)