Part Overview

The SDP606 is a differential pressure sensor manufactured by Sensirion AG, designed for board mount applications with a measurement range of ±0.07PSI (±0.5kPa). The sensor features 16-bit digital output via I2C interface, temperature compensation, and operates across -20°C to 80°C. The product is currently obsolete, making identification of suitable substitute components essential for ongoing system support and new design implementations.

Substiute Parts

SDP606
Sensirion AGIn Stock: 766SDP606 Datasheet
SDP606
Current Part
SDP800-500PA
Sensirion AGIn Stock: 1659SDP800-500PA Datasheet
SDP800-500PA
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number SDP606
Manufacturer Sensirion AG
Product Status Obsolete
Pressure Type Differential
Operating Pressure Range ±0.07PSI (±0.5kPa)
Output Type I2C
Output Resolution 16-bit
Accuracy ±3%
Supply Voltage 2.7V ~ 3.3V
Operating Temperature -20°C ~ 80°C
Package Type 4-SIP Module
Mounting Type Through Hole
Features Temperature Compensated
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution of the SDP606 is determined by the following critical parameters:

  • Pressure Measurement Range: Operating pressure must match or exceed ±0.07PSI (±0.5kPa) differential capability
  • Output Interface: I2C digital output is required for system compatibility
  • Output Resolution: 16-bit resolution maintains data precision equivalence
  • Measurement Accuracy: ±3% accuracy specification must be maintained
  • Supply Voltage Compatibility: Substitute must operate within available system voltage rails
  • Operating Temperature Range: Must support the required thermal operating window
  • Temperature Compensation: Required for stable performance across temperature variations
  • Regulatory Compliance: ROHS3 and REACH compliance status must be maintained

The SDP800-500PA qualifies as a direct substitute based on matching these core electrical and functional parameters while offering an active product status and enhanced availability.

Parameter Comparison

Parameter SDP606 SDP800-500PA Compatibility Notes
Manufacturer Sensirion AG Sensirion AG Same manufacturer ensures design consistency
Pressure Type Differential Differential Identical pressure measurement type
Operating Pressure Range ±0.07PSI (±0.5kPa) -0.07PSI ~ 0.07PSI (-0.5kPa ~ 0.5kPa) Equivalent measurement range
Output Type I2C I2C Identical digital interface
Output Resolution 16-bit 16-bit Equivalent data resolution
Accuracy ±3% ±3% Identical accuracy specification
Supply Voltage 2.7V ~ 3.3V 3V ~ 5.5V SDP800-500PA supports wider voltage range; 3.3V operation confirmed
Operating Temperature -20°C ~ 80°C -20°C ~ 85°C SDP800-500PA extends upper temperature limit by 5°C
Temperature Compensation Yes Yes Both include temperature compensation
Maximum Pressure Rating ±72.52PSI (±500kPa) 14.5PSI (100kPa) SDP606 has higher overpressure rating; verify application requirements
Product Status Obsolete Active SDP800-500PA is actively manufactured and supported
RoHS Status ROHS3 Compliant ROHS3 Compliant Both meet regulatory requirements
REACH Status REACH Unaffected REACH Unaffected Both comply with REACH regulations

Engineering Selection Recommendations

The SDP800-500PA is the qualified substitute for the obsolete SDP606 based on functional equivalence across all critical electrical and measurement parameters. Both sensors maintain identical I2C output, 16-bit resolution, ±3% accuracy, and temperature compensation characteristics required for system operation.

The SDP800-500PA offers the following advantages:

  • Active product status with ongoing manufacturer support and availability
  • Extended supply voltage range (3V ~ 5.5V) providing greater design flexibility
  • Expanded operating temperature range (-20°C ~ 85°C) for enhanced thermal margin
  • ROHS3 and REACH compliance maintained for regulatory continuity

Design consideration: The SDP800-500PA features a male 0.2" (5.2mm) tube port with barbless connection style, whereas the SDP606 has no port. Mechanical integration requirements must be evaluated for specific applications. The SDP800-500PA's maximum pressure rating of 14.5PSI (100kPa) is lower than the SDP606's ±72.52PSI (±500kPa); applications requiring higher overpressure protection must confirm compatibility with the reduced rating.

Frequently Asked Questions (FAQ)

Q: Can the SDP800-500PA directly replace the SDP606 in existing designs?

A: The SDP800-500PA provides electrical and functional equivalence for I2C communication, measurement range, resolution, and accuracy. However, mechanical integration differs due to the SDP800-500PA's 0.2" tube port connection. PCB layout and mechanical mounting must be reassessed for compatibility.

Q: What is the primary reason for substitution?

A: The SDP606 is obsolete and no longer manufactured. The SDP800-500PA is an active product from the same manufacturer with equivalent measurement specifications and digital interface characteristics.

Q: Are there voltage supply differences that affect circuit design?

A: The SDP606 operates at 2.7V ~ 3.3V, while the SDP800-500PA operates at 3V ~ 5.5V. Both sensors function at 3.3V, a common system voltage. If the original design uses 2.7V operation, the SDP800-500PA's 3V minimum may require circuit adjustment.

Q: How do the pressure ratings compare?

A: Both sensors measure differential pressure in the ±0.07PSI (±0.5kPa) range with identical accuracy. The SDP606 has a maximum overpressure rating of ±72.52PSI (±500kPa), while the SDP800-500PA is rated to 14.5PSI (100kPa). Applications subject to high overpressure conditions must verify the SDP800-500PA's lower rating is acceptable.

Q: What is the difference in package and port configuration?

A: The SDP606 is a 4-SIP through-hole module with no port connection. The SDP800-500PA is a module with a male 0.2" (5.2mm) tube port using a barbless connection style. Applications requiring direct pressure sensing without tubing must evaluate this mechanical difference.

Q: Are both sensors compliant with regulatory requirements?

A: Both the SDP606 and SDP800-500PA are ROHS3 compliant and REACH unaffected, maintaining regulatory continuity for applications with these compliance requirements.