SDP1000-L Equivalent & Substitute Parts

Part Overview

The SDP1000-L is a differential pressure sensor manufactured by Sensirion AG, designed for board mount applications with a measurement range of -0.003PSI to 0.072PSI (-0.02kPa to 0.5kPa). The sensor features analog voltage output (0.25V to 4V), temperature compensation, and barbed male connection ports (0.2" / 5.2mm tube, dual). However, the SDP1000-L carries a "Not For New Designs" product status, making identification of functionally equivalent alternatives essential for ongoing system support and new development initiatives.

Substiute Parts

SDP1000-L
Sensirion AGIn Stock: 1413SDP1000-L Datasheet
SDP1000-L
Current Part
SDP816-500PA
Sensirion AGIn Stock: 1473SDP816-500PA Datasheet
SDP816-500PA
MFR Recommended

Key Parameters

Parameter SDP1000-L Value
Manufacturer Sensirion AG
Series SDP1000
Pressure Type Differential
Operating Pressure Range -0.003PSI ~ 0.072PSI (-0.02kPa ~ 0.5kPa)
Output Type Analog Voltage
Output Voltage Range 0.25V ~ 4V
Accuracy ±0.2%
Supply Voltage 4.75V ~ 5.25V
Port Size Male - 0.2" (5.2mm) Tube, Dual
Port Style Barbed
Operating Temperature -10°C ~ 60°C
Maximum Pressure 14.5PSI (100kPa)
Package Type Module
RoHS Status ROHS3 Compliant
Product Status Not For New Designs

Substitute Part Grouping Explanation

The SDP816-500PA qualifies as a manufacturer-recommended substitute for the SDP1000-L based on the following critical parameters:

Mechanical Compatibility: Both sensors feature identical port configurations (Male - 0.2" / 5.2mm tube, dual barbed connections), ensuring direct physical compatibility in existing installations.

Functional Equivalence: Both are differential pressure sensors with analog voltage output, temperature compensation, and identical maximum pressure ratings (14.5PSI / 100kPa).

Pressure Range Overlap: The SDP816-500PA operating range (-0.07PSI ~ 0.07PSI / -0.5kPa ~ 0.5kPa) encompasses the SDP1000-L range (-0.003PSI ~ 0.072PSI / -0.02kPa ~ 0.5kPa), providing measurement capability across the original sensor's full operating envelope.

Electrical Interface: Both sensors provide analog voltage output with supply voltage compatibility within overlapping ranges, enabling direct integration into existing signal conditioning circuits.

Regulatory Compliance: Both sensors maintain ROHS3 compliance and REACH unaffected status, meeting equivalent environmental and regulatory requirements.

Parameter Comparison

Parameter SDP1000-L SDP816-500PA Compatibility Notes
Manufacturer Sensirion AG Sensirion AG Same manufacturer
Pressure Type Differential Differential Identical
Operating Pressure Range -0.003PSI ~ 0.072PSI -0.07PSI ~ 0.07PSI SDP816-500PA range encompasses SDP1000-L
Output Type Analog Voltage Analog Voltage Identical
Output Voltage Range 0.25V ~ 4V 0.5V ~ 4.5V Overlapping ranges; SDP816-500PA has extended upper limit
Accuracy ±0.2% ±3% SDP1000-L has higher accuracy; SDP816-500PA acceptable for applications tolerating ±3%
Supply Voltage 4.75V ~ 5.25V 3V ~ 5.5V SDP816-500PA has wider supply range; 5V nominal compatible with both
Port Size Male - 0.2" (5.2mm) Tube, Dual Male - 0.2" (5.2mm) Tube, Dual Identical mechanical interface
Port Style Barbed Barbed Identical
Operating Temperature -10°C ~ 60°C -20°C ~ 85°C SDP816-500PA has extended temperature range
Maximum Pressure 14.5PSI (100kPa) 14.5PSI (100kPa) Identical
Package Type Module Module Identical
RoHS Status ROHS3 Compliant ROHS3 Compliant Equivalent compliance
Product Status Not For New Designs Active SDP816-500PA is actively supported

Engineering Selection Recommendations

For Existing SDP1000-L Installations: The SDP816-500PA serves as a direct mechanical and functional replacement. The identical port configuration and pressure sensor type enable drop-in substitution without mechanical redesign. Supply voltage compatibility at 5V nominal operation supports existing power distribution circuits.

For New Designs: The SDP816-500PA is the appropriate selection due to its Active product status. The SDP1000-L "Not For New Designs" designation indicates manufacturer discontinuation trajectory, making the SDP816-500PA the supported path forward for ongoing development.

Accuracy Considerations: Applications requiring ±0.2% accuracy must account for the SDP816-500PA's ±3% accuracy specification. Systems with tolerance budgets accommodating ±3% accuracy will experience no functional degradation. Applications with tighter accuracy requirements may require signal conditioning or calibration adjustments.

Temperature Range Extension: The SDP816-500PA operating range (-20°C ~ 85°C) exceeds the SDP1000-L range (-10°C ~ 60°C), providing enhanced capability for extended environmental conditions without additional thermal management.

Regulatory Compliance: Both sensors maintain equivalent ROHS3 and REACH compliance status, satisfying identical environmental and regulatory requirements for component selection.

Frequently Asked Questions (FAQ)

Q: Can the SDP816-500PA directly replace the SDP1000-L in existing applications?

A: Yes. The SDP816-500PA provides mechanical compatibility through identical port configuration (Male - 0.2" barbed tube, dual), functional equivalence as a differential pressure sensor with analog voltage output, and electrical compatibility within the 5V nominal supply range. No mechanical redesign is required.

Q: What are the key differences between these sensors?

A: The primary differences are accuracy (SDP1000-L ±0.2% versus SDP816-500PA ±3%), operating temperature range (SDP1000-L -10°C ~ 60°C versus SDP816-500PA -20°C ~ 85°C), output voltage range (SDP1000-L 0.25V ~ 4V versus SDP816-500PA 0.5V ~ 4.5V), and product status (SDP1000-L Not For New Designs versus SDP816-500PA Active).

Q: Will the ±3% accuracy of the SDP816-500PA affect system performance?

A: Accuracy impact depends on application requirements. Systems designed with tolerance budgets accommodating ±3% accuracy will function without degradation. Applications requiring ±0.2% accuracy must evaluate whether the increased tolerance is acceptable or whether signal conditioning is necessary.

Q: Are the pressure measurement ranges compatible?

A: Yes. The SDP816-500PA pressure range (-0.07PSI ~ 0.07PSI) fully encompasses the SDP1000-L range (-0.003PSI ~ 0.072PSI), ensuring measurement capability across the original sensor's complete operating envelope.

Q: What supply voltage should be used for the SDP816-500PA?

A: The SDP816-500PA accepts 3V ~ 5.5V supply voltage. For compatibility with existing SDP1000-L circuits designed for 4.75V ~ 5.25V operation, 5V nominal supply is appropriate and falls within both sensors' acceptable ranges.

Q: Is the SDP816-500PA suitable for new product designs?

A: Yes. The SDP816-500PA carries Active product status, indicating manufacturer support and availability for ongoing development. The SDP1000-L "Not For New Designs" designation makes the SDP816-500PA the recommended selection for new applications.

Q: Are there any package or form factor differences?

A: No. Both sensors are supplied in Module package type with identical physical form factors, enabling direct substitution without enclosure or mounting modifications.

Request Quote (Ships tomorrow)