Part Overview

The SCX147-201 is an unshielded 2-coil inductor array manufactured by Signal Transformer, designed for surface mount applications. This component provides dual inductance configurations: 802.82 µH when coils are connected in series and 200 µH when connected in parallel. The part is classified as obsolete, making identification of functionally equivalent alternatives essential for ongoing design support and procurement continuity.

Substiute Parts

SCX147-201
Signal TransformerIn Stock: 1253SCX147-201 Datasheet
SCX147-201
Current Part
CTX200-4-R
Eaton - Electronics DivisionIn Stock: 4436CTX200-4-R Datasheet
CTX200-4-R
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number SCX147-201
Manufacturer Signal Transformer
Number of Coils 2
Inductance - Parallel Configuration 200 µH
Inductance - Series Configuration 802.82 µH
Tolerance ±20%
Current Rating - Parallel 640 mA
Current Rating - Series 320 mA
DC Resistance (DCR) - Parallel 545 mOhm Max
DC Resistance (DCR) - Series 2.18 Ohm Max
Shielding Unshielded
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.567" L x 0.567" W (14.40mm x 14.40mm)
Height 0.276" (7.00mm)
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution eligibility for the SCX147-201 is determined by the following critical parameters:

  • Coil Configuration: 2-coil inductor array with identical series and parallel inductance values (802.82 µH series, 200 µH parallel)
  • Inductance Tolerance: ±20% tolerance band
  • Current Ratings: 640 mA parallel configuration, 320 mA series configuration
  • DC Resistance: 545 mOhm maximum (parallel), 2.18 Ohm maximum (series)
  • Shielding Type: Unshielded construction
  • Mounting Technology: Surface mount package
  • Compliance: ROHS3 compliant, MSL Level 1

The CTX200-4-R from Eaton - Electronics Division meets all substitution criteria within the specified tolerance and performance parameters.

Parameter Comparison

Parameter SCX147-201 CTX200-4-R Match Status
Number of Coils 2 2 Identical
Inductance - Parallel Configuration 200 µH 200.7 µH Within ±20% Tolerance
Inductance - Series Configuration 802.82 µH 802.82 µH Identical
Tolerance ±20% ±20% Identical
Current Rating - Parallel 640 mA 640 mA Identical
Current Rating - Series 320 mA 320 mA Identical
DC Resistance (DCR) - Parallel 545 mOhm Max 545 mOhm Max Identical
DC Resistance (DCR) - Series 2.18 Ohm Max 2.18 Ohm Max Identical
Shielding Unshielded Unshielded Identical
Mounting Type Surface Mount Surface Mount Identical
Package / Case Nonstandard Nonstandard Identical
RoHS Status ROHS3 Compliant ROHS3 Compliant Identical
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) Identical
Product Status Obsolete Active Substitute is Active
Operating Temperature Range Not specified -40°C ~ 85°C CTX200-4-R provides defined range

Engineering Selection Recommendations

The CTX200-4-R is the qualified substitute for the obsolete SCX147-201 based on the following engineering criteria:

Electrical Equivalence: All critical electrical parameters match within specified tolerances. The parallel inductance of 200.7 µH falls within the ±20% tolerance band of the original 200 µH specification. Series inductance, current ratings, and DC resistance values are identical.

Compliance Status: Both components maintain ROHS3 compliance and MSL Level 1 rating, ensuring compatibility with current manufacturing and environmental standards.

Product Availability: The CTX200-4-R is classified as active product status with 4400 units in stock, providing procurement continuity for the obsolete SCX147-201.

Mechanical Compatibility: Both components are surface mount, unshielded 2-coil inductor arrays in nonstandard packages with comparable physical dimensions (14.40mm x 14.40mm x 7.00mm for SCX147-201 versus 13.97mm x 13.97mm x 6.35mm for CTX200-4-R).

Frequently Asked Questions (FAQ)

Q: Can the CTX200-4-R directly replace the SCX147-201 in existing designs?

A: Yes. The CTX200-4-R meets all electrical and mechanical substitution criteria. The parallel inductance variance of 0.7 µH (200.7 µH versus 200 µH) is within the ±20% tolerance specification. All current ratings, DC resistance values, and compliance certifications are identical.

Q: What is the difference in physical dimensions between these parts?

A: The SCX147-201 measures 14.40mm x 14.40mm x 7.00mm, while the CTX200-4-R measures 13.97mm x 13.97mm x 6.35mm. Both are nonstandard package formats. Verify PCB layout compatibility before implementation.

Q: Are there packaging differences between the original and substitute?

A: The SCX147-201 packaging format is not specified in available data. The CTX200-4-R is supplied in Tape & Reel (TR) format. Confirm packaging requirements for your procurement and assembly processes.

Q: Why is the SCX147-201 classified as obsolete?

A: Product obsolescence is determined by the manufacturer. The CTX200-4-R, as an active product from Eaton - Electronics Division, provides functional continuity for applications requiring 2-coil inductor arrays with 200 µH parallel and 802.82 µH series configurations.

Q: Are the operating temperature ranges compatible?

A: The SCX147-201 operating temperature range is not specified in available documentation. The CTX200-4-R operates across -40°C to 85°C. Confirm your application's temperature requirements against the CTX200-4-R specification.

Q: What compliance certifications apply to both components?

A: Both the SCX147-201 and CTX200-4-R are ROHS3 compliant with MSL Level 1 rating. Both carry EAR99 ECCN classification. The CTX200-4-R is REACH unaffected.