SCW03B-12 Equivalent & Substitute Parts Reference

Part Overview

The MEAN WELL USA Inc. SCW03B-12 is an isolated module DC-DC converter delivering 12V at 250mA output (3W) with a 1kV isolation voltage. It accepts a wide input voltage range (18V - 36V) and provides robust features such as Over Current Protection (OCP) and Short Circuit Protection (SCP). The SCW03B-12 is provided in a 24-DIP module with 8 leads, sized 1.25" x 0.80" x 0.48". This part is marked as Obsolete, making it necessary to find alternative models for continued availability and supply chain assurance in compatible applications.

Substiute Parts

SCW03B-12
MEAN WELL USA Inc.In Stock: 2080SCW03B-12 Datasheet
SCW03B-12
Current Part
SCWN03B-12
MEAN WELL USA Inc.In Stock: 1277SCWN03B-12 Datasheet
SCWN03B-12
Direct
REC3-2412SRW/H4/A
Recom PowerIn Stock: 59793REC3-2412SRW/H4/A Datasheet
REC3-2412SRW/H4/A
Similar

Key Parameters

ParameterValue
Manufacturer Part NumberSCW03B-12
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)18V
Voltage - Input (Max)36V
Voltage - Output 112V
Current - Output (Max)250mA
Power (Watts)3 W
Voltage - Isolation1 kV
FeaturesOCP, SCP
Operating Temperature-40°C ~ 71°C (With Derating)
Efficiency80%
Mounting TypeThrough Hole
Package / Case24-DIP Module, 8 Leads
Size / Dimension1.25" L x 0.80" W x 0.48" H (31.8mm x 20.3mm x 12.2mm)
RoHS StatusROHS3 Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)
REACH StatusREACH Unaffected

Substitute Part Grouping Explanation

Substitution is carried out strictly based on electrical and mechanical compatibility:

  • Input voltage range (18V - 36V)
  • Output voltage (12V)
  • Maximum output current (250mA)
  • Power rating (3W)
  • Isolation voltage (≥1kV)
  • Output type and quantity (Isolated Module, single output)
  • Mounting type (Through Hole)
  • Package format and dimensions (24-DIP Module, 8 Leads)
  • Regulatory and compliance attributes (RoHS, MSL, REACH)
  • Integrated features (OCP, SCP, or equivalent)

Only products matching or exceeding these criteria are considered as valid substitutes.

Parameter Comparison

Parameter Main Part
SCW03B-12
Direct Substitute
SCWN03B-12
Similar Substitute
REC3-2412SRW/H4/A
Manufacturer MEAN WELL USA Inc. MEAN WELL USA Inc. Recom Power
Type Isolated Module Isolated Module Isolated Module
Number of Outputs 1 1 1
Voltage - Input (Min) 18V 18V 18V
Voltage - Input (Max) 36V 36V 36V
Voltage - Output 1 12V 12V 12V
Current - Output (Max) 250mA 250mA 250mA
Power (Watts) 3 W 3 W 3 W
Voltage - Isolation 1 kV 3 kV 4 kV
Features OCP, SCP OCP, SCP, UVLO SCP
Operating Temperature -40°C ~ 71°C (With Derating) -40°C ~ 90°C (With Derating) -40°C ~ 85°C
Efficiency 80% 86% 85%
Mounting Type Through Hole Through Hole Through Hole
Package / Case 24-DIP Module, 8 Leads 24-DIP Module, 8 Leads 24-DIP Module, 8 Leads
Size / Dimension 1.25" x 0.80" x 0.48" 1.25" x 0.80" x 0.40" 1.26" x 0.80" x 0.40"
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

Selection between SCW03B-12, SCWN03B-12, and REC3-2412SRW/H4/A should be based on product status and compliance. SCW03B-12 is Obsolete, and the substitutes SCWN03B-12 and REC3-2412SRW/H4/A are Active. All listed parts hold ROHS3 compliance, Unlimited (MSL 1) Moisture Sensitivity, and unaffected REACH status, ensuring conformity with standard regulatory requirements.

Frequently Asked Questions (FAQ)

Q1: What are the primary parameters for substituting SCW03B-12?
A1: Substitution is based on input voltage range, output voltage and current, power rating, isolation voltage, features, mounting type, package, and compliance statuses.

Q2: Is package compatibility maintained among substitutes?
A2: Yes. All listed substitutes use the 24-DIP Module, 8 Leads package and support Through Hole mounting.

Q3: Are substitute parts RoHS and REACH compliant?
A3: Yes. All parts are ROHS3 Compliant and REACH Unaffected.

Q4: How does the operating temperature range compare among substitutes?
A4: SCW03B-12 operates from -40°C to +71°C. SCWN03B-12 and REC3-2412SRW/H4/A have wider operational temperature ranges.

Q5: Do the substitutes provide the same or higher electrical isolation?
A5: Yes. Substitute parts have equal or greater voltage isolation ratings than the SCW03B-12.

Q6: Are all listed parts in active production?
A6: SCW03B-12 is Obsolete. SCWN03B-12 and REC3-2412SRW/H4/A are Active.

Request Quote (Ships tomorrow)