SCRH62B-120 Equivalent & Substitute Parts

Part Overview

The SCRH62B-120 is a 12 µH shielded surface mount inductor manufactured by Signal Transformer, rated for 1.24 A continuous current with a maximum DC resistance of 200mOhm. This component is classified as obsolete, making substitute parts necessary for new designs and ongoing production requirements. The part operates across the industrial temperature range of -40°C to 125°C and meets ROHS3 compliance standards.

Substiute Parts

SCRH62B-120
Signal TransformerIn Stock: 1070SCRH62B-120 Datasheet
SCRH62B-120
Current Part
CDR6D28MNNP-120NC
Sumida America Components Inc.In Stock: 821CDR6D28MNNP-120NC Datasheet
CDR6D28MNNP-120NC
MFR Recommended

Key Parameters

Parameter Value
Inductance 12 µH
Inductance Tolerance ±20%
Current Rating 1.24 A
Saturation Current (Isat) 1 A
DC Resistance (DCR) 200mOhm Max
Shielding Shielded
Operating Temperature Range -40°C to 125°C
Mounting Type Surface Mount
Package Type Nonstandard
Physical Dimensions 6.50mm L x 6.40mm W x 3.20mm H
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level MSL 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the SCRH62B-120 is based on the following critical electrical and mechanical parameters:

Primary Matching Criteria:

  • Inductance value: 12 µH (fixed requirement)
  • Inductance test frequency: 100 kHz
  • Shielding type: Shielded
  • Mounting technology: Surface Mount
  • Physical form factor: Nonstandard package with compatible dimensions

Secondary Compatibility Parameters:

  • Current rating must meet or exceed 1.24 A
  • DC resistance must not exceed 200mOhm
  • Operating temperature range must cover -40°C to 125°C or be compatible with application requirements
  • RoHS3 compliance required

The CDR6D28MNNP-120NC from Sumida America Components Inc. qualifies as a direct substitute based on matching inductance, shielding, mounting type, and compliance certifications, while offering improved electrical performance characteristics.

Parameter Comparison

Parameter SCRH62B-120 (Main Part) CDR6D28MNNP-120NC (Substitute)
Manufacturer Signal Transformer Sumida America Components Inc.
Inductance 12 µH 12 µH
Inductance Tolerance ±20% ±25%
Current Rating (Amps) 1.24 A 1.5 A
Saturation Current (Isat) 1 A 2.3 A
DC Resistance (DCR) 200mOhm Max 120mOhm Max
Shielding Shielded Shielded
Operating Temperature Range -40°C to 125°C -40°C to 105°C
Inductance Test Frequency 100 kHz 100 kHz
Mounting Type Surface Mount Surface Mount
Package Type Nonstandard Nonstandard
Physical Dimensions 6.50mm L x 6.40mm W x 3.20mm H 6.50mm L x 6.50mm W x 3.00mm H
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level MSL 1 (Unlimited) MSL 1 (Unlimited)
Product Status Obsolete Active

Engineering Selection Recommendations

The CDR6D28MNNP-120NC is the qualified substitute for the obsolete SCRH62B-120. Selection is based on:

Electrical Compatibility: Both parts maintain 12 µH inductance at 100 kHz test frequency. The substitute provides superior electrical performance with lower DC resistance (120mOhm vs. 200mOhm) and higher current ratings (1.5 A vs. 1.24 A), ensuring reliable operation within the original design specifications.

Compliance Status: Both components meet ROHS3 requirements and carry MSL 1 moisture sensitivity classification, confirming equivalent environmental compliance for manufacturing and storage.

Product Availability: The substitute part is classified as Active with confirmed inventory (737 pcs), whereas the main part is Obsolete. This availability difference necessitates the substitution for ongoing production and new design implementations.

Thermal Consideration: The substitute operates to 105°C maximum, compared to the main part's 125°C upper limit. Applications requiring operation above 105°C require thermal analysis or alternative component selection.

Physical Form Factor: Dimensional compatibility is maintained with minor height variation (3.00mm vs. 3.20mm), suitable for standard PCB assembly processes.

Frequently Asked Questions (FAQ)

Q: Can CDR6D28MNNP-120NC directly replace SCRH62B-120 in existing designs?

A: Yes, for applications operating within -40°C to 105°C. The substitute maintains identical inductance value, shielding type, and mounting technology. Verify thermal requirements if the original design specified operation above 105°C.

Q: What are the key electrical differences between these parts?

A: The substitute offers lower DC resistance (120mOhm vs. 200mOhm) and higher current rating (1.5 A vs. 1.24 A). These represent performance improvements that maintain backward compatibility with the original design envelope.

Q: Are there packaging or handling differences?

A: Both parts carry MSL 1 classification with unlimited shelf life under controlled storage. The substitute is supplied in Tape & Reel packaging. Physical dimensions are nearly identical with a 0.2mm height difference, which does not affect standard PCB assembly compatibility.

Q: Why is the main part classified as Obsolete?

A: The SCRH62B-120 is no longer in active production. The CDR6D28MNNP-120NC represents the current active equivalent from an alternative manufacturer, ensuring continued supply chain access for this inductance value and specification class.

Q: What compliance certifications apply to both parts?

A: Both components are ROHS3 compliant and carry REACH Unaffected status. ECCN classification is EAR99 for both parts, confirming equivalent export control treatment.

Request Quote (Ships tomorrow)