Request Quote
(Ships tomorrow)
SCRH62-470 Equivalent & Substitute Parts
Part Overview
The SCRH62-470 is a 47 µH shielded inductor manufactured by Signal Transformer, designed for surface mount applications requiring 750 mA current rating with 690mOhm maximum DC resistance. This component is classified as Active product status with full RoHS3 compliance. Substitute parts are identified when equivalent inductance values, shielding characteristics, and operating temperature ranges align with application requirements, enabling procurement flexibility and supply chain continuity.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Inductance | 47 µH |
| Inductance Tolerance | ±20% |
| Current Rating | 750 mA |
| DC Resistance (DCR) | 690mOhm Max |
| Shielding | Shielded |
| Mounting Type | Surface Mount |
| Operating Temperature Range | -40°C ~ 125°C |
| Package Type | Nonstandard |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution eligibility for the SCRH62-470 is determined by the following critical parameters:
Primary Matching Criteria:
- Inductance value: 47 µH (±20% tolerance acceptable)
- Shielding requirement: Shielded configuration mandatory
- Mounting technology: Surface mount only
- Package classification: Nonstandard
Secondary Compatibility Factors:
- Current rating must meet or exceed application requirements
- DC resistance within acceptable operating margins
- Operating temperature range must encompass application environment
- RoHS3 compliance and MSL rating for manufacturing process compatibility
The VLCF5020T-470MR40 qualifies as a substitute based on matching inductance, shielding, surface mount configuration, and compliance certifications. Current rating differences require application-level verification.
Parameter Comparison
| Parameter | SCRH62-470 (Main) | VLCF5020T-470MR40 (Substitute) |
|---|---|---|
| Manufacturer | Signal Transformer | TDK Corporation |
| Inductance | 47 µH | 47 µH |
| Inductance Tolerance | ±20% | ±20% |
| Current Rating (Amps) | 750 mA | 400 mA |
| Current - Saturation (Isat) | 500mA | 400mA |
| DC Resistance (DCR) | 690mOhm Max | 748mOhm Max |
| Shielding | Shielded | Shielded |
| Operating Temperature | -40°C ~ 125°C | -40°C ~ 105°C |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | Nonstandard | Nonstandard |
| Size / Dimension | 0.280" L x 0.256" W (7.10mm x 6.50mm) | 0.197" L x 0.197" W (5.00mm x 5.00mm) |
| Height - Seated (Max) | 0.118" (3.00mm) | 0.079" (2.00mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
Both the SCRH62-470 and VLCF5020T-470MR40 maintain Active product status with ROHS3 compliance and MSL Level 1 ratings, ensuring manufacturing process compatibility and long-term availability. The primary differentiation factor is current rating capacity: the SCRH62-470 supports 750 mA continuous operation, while the VLCF5020T-470MR40 is rated for 400 mA. Selection between these parts must be based on circuit current requirements. The VLCF5020T-470MR40 offers reduced physical footprint (5.00mm x 5.00mm versus 7.10mm x 6.50mm) and lower profile height (2.00mm versus 3.00mm), providing layout advantages in space-constrained applications where current demands do not exceed 400 mA. Operating temperature range differs by 20°C maximum; the SCRH62-470 extends to 125°C while the VLCF5020T-470MR40 operates to 105°C.
Frequently Asked Questions (FAQ)
Q: Can VLCF5020T-470MR40 replace SCRH62-470 in all applications?
A: Substitution is valid only when circuit current requirements do not exceed 400 mA. The VLCF5020T-470MR40 saturation current is 400mA compared to 500mA for the SCRH62-470. Applications requiring sustained current above 400 mA must use the SCRH62-470.
Q: What is the impact of DC resistance difference between these parts?
A: The VLCF5020T-470MR40 exhibits 748mOhm maximum DCR versus 690mOhm for the SCRH62-470, representing a 58mOhm increase. This affects power dissipation and thermal performance; calculate I²R losses for your specific current to determine acceptability.
Q: Are physical dimensions interchangeable?
A: No. The VLCF5020T-470MR40 is significantly smaller (5.00mm x 5.00mm x 2.00mm) compared to the SCRH62-470 (7.10mm x 6.50mm x 3.00mm). PCB layout and component placement must be re-evaluated. The smaller footprint may require design modifications to accommodate.
Q: Do both parts meet the same compliance requirements?
A: Yes. Both components are ROHS3 compliant, REACH unaffected, and classified as MSL Level 1 (Unlimited moisture sensitivity). Manufacturing process compatibility is equivalent.
Q: What is the operating temperature consideration?
A: The SCRH62-470 operates across -40°C to 125°C, while the VLCF5020T-470MR40 operates -40°C to 105°C. Applications requiring operation above 105°C must use the SCRH62-470.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts