SCC100D Pressure Sensor Equivalent & Substitute Parts

Part Overview

The SCC100D is a differential pressure sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for board mount applications with a 100PSI (689.48kPa) differential pressure range and Wheatstone Bridge output. The sensor operates across -40°C to 85°C and features temperature compensation with ±0.5% accuracy.

The SCC100D is classified as an obsolete product. Identifying equivalent and substitute parts is necessary to maintain system functionality, ensure supply chain continuity, and support legacy equipment maintenance where direct replacement with the original part number is no longer feasible.

Substiute Parts

SCC100D
Honeywell Sensing and Productivity SolutionsIn Stock: 888SCC100D Datasheet
SCC100D
Current Part
NSCSSNN100PDUNV
Honeywell Sensing and Productivity SolutionsIn Stock: 1755NSCSSNN100PDUNV Datasheet
NSCSSNN100PDUNV
Direct

Key Parameters

Parameter SCC100D
Pressure Type Differential
Operating Pressure 100PSI (689.48kPa)
Output Type Wheatstone Bridge
Output Range 85 mV ~ 225 mV
Accuracy ±0.5%
Operating Temperature -40°C ~ 85°C
Mounting Type Through Hole
Package Type 5-DIP Module
Termination Style PC Pin
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the SCC100D is based on the following critical parameters that must align between the main part and substitute candidates:

Pressure Measurement Capability: The substitute must support differential pressure measurement at or above 100PSI operating range.

Output Signal Type: The substitute must provide Wheatstone Bridge output to maintain compatibility with existing signal conditioning and measurement circuits.

Operating Temperature Range: The substitute must cover the full -40°C to 85°C operating window.

Mounting and Termination: The substitute must use through-hole mounting with PC pin termination to ensure mechanical and electrical compatibility with existing PCB layouts.

Electrical Interface: The substitute must operate within compatible voltage supply ranges and produce output signals compatible with downstream electronics.

The NSCSSNN100PDUNV meets these substitution criteria. It provides differential pressure measurement with ±100PSI range (exceeding the 100PSI requirement), Wheatstone Bridge output, identical operating temperature range, through-hole mounting with PC pin termination, and operates on 1.5V ~ 12V supply voltage.

Parameter Comparison

Parameter SCC100D NSCSSNN100PDUNV Compatibility Notes
Manufacturer Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions Same manufacturer ensures design consistency
Pressure Type Differential Differential Identical pressure measurement type
Operating Pressure 100PSI (689.48kPa) ±100PSI (±689.48kPa) Substitute range meets or exceeds requirement
Maximum Pressure 150PSI (1034.21kPa) ±250PSI (±1723.69kPa) Substitute provides higher overpressure protection
Output Type Wheatstone Bridge Wheatstone Bridge Identical output signal type
Output Range 85 mV ~ 225 mV 0 mV ~ 172.5 mV (5V) Different output levels; signal conditioning adjustment required
Accuracy ±0.5% ±0.25% Substitute provides improved accuracy
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C Identical temperature range
Mounting Type Through Hole Through Hole Identical mounting method
Package Type 5-DIP Module 4-SIP Module Different package footprint; PCB layout modification required
Termination Style PC Pin PC Pin Identical termination method
Voltage Supply Not specified 1.5V ~ 12V Substitute operates across wide supply voltage range
Product Status Obsolete Active Substitute is currently in production
RoHS Status RoHS Compliant RoHS Compliant Both parts meet RoHS requirements

Engineering Selection Recommendations

Product Status Consideration: The SCC100D is obsolete, making the NSCSSNN100PDUNV the appropriate active alternative from the same manufacturer. The substitute is currently in production with established supply chain availability.

Compliance Alignment: Both parts are RoHS Compliant and REACH Unaffected, maintaining regulatory compliance for new designs and legacy system updates.

Functional Compatibility: The NSCSSNN100PDUNV provides equivalent differential pressure measurement capability with superior accuracy (±0.25% versus ±0.5%) and higher overpressure rating (±250PSI versus 150PSI).

Implementation Considerations: Direct substitution requires two modifications: (1) PCB layout adjustment due to package change from 5-DIP to 4-SIP, and (2) signal conditioning circuit adjustment to accommodate the different output voltage range (0 mV ~ 172.5 mV versus 85 mV ~ 225 mV).

Supply Voltage: Verify that the system power supply falls within the NSCSSNN100PDUNV operating range of 1.5V ~ 12V. The original SCC100D supply voltage specification is not provided in available documentation.

Frequently Asked Questions (FAQ)

Q: Can the NSCSSNN100PDUNV be used as a direct drop-in replacement for the SCC100D?

A: No. While both sensors provide differential pressure measurement with Wheatstone Bridge output and identical operating temperature ranges, the NSCSSNN100PDUNV requires PCB layout modification due to package change (5-DIP to 4-SIP) and signal conditioning adjustment for the different output voltage range.

Q: What is the key difference in output signal between these two sensors?

A: The SCC100D outputs 85 mV ~ 225 mV, while the NSCSSNN100PDUNV outputs 0 mV ~ 172.5 mV at 5V supply. Downstream signal conditioning circuits must be recalibrated to accommodate this difference.

Q: Does the NSCSSNN100PDUNV provide better performance than the SCC100D?

A: The NSCSSNN100PDUNV offers improved accuracy (±0.25% versus ±0.5%) and higher overpressure protection (±250PSI versus 150PSI). Both sensors maintain identical operating temperature range and pressure measurement type.

Q: Are both sensors RoHS compliant?

A: Yes. Both the SCC100D and NSCSSNN100PDUNV are RoHS Compliant and REACH Unaffected, meeting current environmental and regulatory requirements.

Q: What supply voltage does the NSCSSNN100PDUNV require?

A: The NSCSSNN100PDUNV operates on 1.5V ~ 12V supply voltage. Verify that your system power supply falls within this range before implementation.

Q: Why is the SCC100D listed as obsolete?

A: The SCC100D has been discontinued by Honeywell Sensing and Productivity Solutions. The NSCSSNN100PDUNV from the TruStability® NSC series represents the active product line for equivalent differential pressure sensing applications.

Q: Can I use the NSCSSNN100PDUNV in the same PCB footprint as the SCC100D?

A: No. The SCC100D uses a 5-DIP Module package, while the NSCSSNN100PDUNV uses a 4-SIP Module package. PCB layout modification is required for mechanical and electrical compatibility.

Request Quote (Ships tomorrow)