SA110-B Equivalent & Substitute Parts

Part Overview

The SA110-B is a unidirectional Transient Voltage Suppressor (TVS) diode manufactured by Littelfuse Inc., designed for transient overvoltage protection in telecom applications. This component features a 110V reverse standoff voltage with a 177V maximum clamping voltage and 2.9A peak pulse current capability in a through-hole DO-204AC (DO-15) axial package.

The SA110-B is classified as obsolete. Identifying equivalent and substitute parts is necessary to maintain design continuity, ensure supply chain availability, and support legacy system maintenance and repairs.

Substiute Parts

SA110-B
Littelfuse Inc.In Stock: 1066SA110-B Datasheet
SA110-B
Current Part
SA110A
Fairchild SemiconductorIn Stock: 3908SA110A Datasheet
SA110A
Direct

Key Parameters

Parameter Value Unit
Voltage - Reverse Standoff (Typ) 110 V
Voltage - Breakdown (Min) 122 V
Voltage - Clamping (Max) @ Ipp 177 V
Current - Peak Pulse (10/1000µs) 2.9 A
Power - Peak Pulse 500 W
Type Zener
Unidirectional Channels 1
Mounting Type Through Hole
Package / Case DO-204AC, DO-15, Axial
Operating Temperature Range -65°C to 175°C TJ

Substitute Part Grouping Explanation

Substitution of the SA110-B is determined by electrical and mechanical parameter equivalence. The following criteria establish valid substitution:

Electrical Parameters (Critical):

  • Voltage - Reverse Standoff (Typ): 110V
  • Voltage - Breakdown (Min): 122V
  • Voltage - Clamping (Max) @ Ipp: 177V
  • Current - Peak Pulse (10/1000µs): 2.9A
  • Power - Peak Pulse: 500W
  • Type: Zener
  • Unidirectional Channels: 1

Mechanical Parameters (Critical):

  • Mounting Type: Through Hole
  • Package / Case: DO-204AC (DO-15) Axial

Environmental Parameters:

  • Operating Temperature Range: -65°C to 175°C (TJ)

The SA110A meets all electrical and mechanical parameter requirements for direct substitution with the SA110-B. Both components are classified as obsolete and share identical voltage ratings, current specifications, power dissipation, package configuration, and temperature operating range.

Parameter Comparison

Parameter SA110-B (Littelfuse) SA110A (Fairchild Semiconductor) Match
Voltage - Reverse Standoff (Typ) 110V 110V Yes
Voltage - Breakdown (Min) 122V 122V Yes
Voltage - Clamping (Max) @ Ipp 177V 177V Yes
Current - Peak Pulse (10/1000µs) 2.9A 2.9A Yes
Power - Peak Pulse 500W 500W Yes
Type Zener Zener Yes
Unidirectional Channels 1 1 Yes
Mounting Type Through Hole Through Hole Yes
Package / Case DO-204AC (DO-15) DO-204AC (DO-15) Yes
Operating Temperature Range -65°C to 175°C (TJ) -55°C to 175°C (TJ) Partial
RoHS Status RoHS Compliant ROHS3 Compliant Yes
Product Status Obsolete Obsolete Yes

Engineering Selection Recommendations

The SA110A (Fairchild Semiconductor) is a direct electrical and mechanical equivalent to the SA110-B. Both components are obsolete products with identical voltage ratings, current specifications, power dissipation capabilities, and package configurations.

Compliance Considerations:

Both the SA110-B and SA110A are RoHS compliant. The SA110-B carries RoHS Compliant certification, while the SA110A carries ROHS3 Compliant certification, indicating both meet current environmental and hazardous substance restrictions.

Temperature Operating Range:

The SA110-B operates from -65°C to 175°C (TJ), while the SA110A operates from -55°C to 175°C (TJ). The SA110-B provides a lower minimum operating temperature specification. Applications requiring operation below -55°C must use the SA110-B. For applications within the -55°C to 175°C range, the SA110A is suitable.

Inventory and Availability:

The SA110A is available in higher inventory (3,863 pcs) compared to the SA110-B (1,039 pcs), supporting supply chain continuity for legacy system support and repairs.

Frequently Asked Questions (FAQ)

Q: Can the SA110A replace the SA110-B in all applications?

A: The SA110A is electrically and mechanically equivalent to the SA110-B for applications operating within the -55°C to 175°C temperature range. Applications requiring operation below -55°C must use the SA110-B due to its extended lower temperature specification of -65°C.

Q: Are the packages identical between SA110-B and SA110A?

A: Yes. Both components use the DO-204AC (DO-15) axial through-hole package. No PCB layout or mechanical modifications are required for substitution within the specified temperature operating range.

Q: What are the critical electrical parameters for substitution?

A: The critical electrical parameters are: 110V reverse standoff voltage, 122V minimum breakdown voltage, 177V maximum clamping voltage, 2.9A peak pulse current, and 500W peak pulse power. Both the SA110-B and SA110A meet these specifications identically.

Q: Do both parts meet RoHS requirements?

A: Yes. The SA110-B is RoHS Compliant, and the SA110A is ROHS3 Compliant. Both meet current environmental and hazardous substance restrictions for electronic components.

Q: Why are both parts classified as obsolete?

A: Both the SA110-B and SA110A are obsolete products. Identifying equivalent substitutes is necessary for maintaining legacy systems and ensuring continued availability for repair and replacement applications.

Q: What is the difference in minimum operating temperature between these parts?

A: The SA110-B operates from -65°C minimum, while the SA110A operates from -55°C minimum. Both reach 175°C maximum. For applications requiring operation below -55°C, the SA110-B is required.

Request Quote (Ships tomorrow)