S22P006S05 Current Sensor Hall Effect Equivalent & Substitute Parts

Part Overview

The S22P006S05 is a Hall Effect closed-loop bidirectional current sensor manufactured by Tamura, designed for AC/DC current measurement applications up to 6A. This component operates as a 1-channel ratiometric voltage output module with a frequency response spanning DC to 100kHz and a response time of 1µs.

The S22P006S05 is classified as obsolete. Locating equivalent or substitute components is necessary to support ongoing system maintenance, design updates, and procurement continuity. The substitute part S22P006S05M2 provides functional equivalence while maintaining active product status.

Substiute Parts

S22P006S05
TamuraIn Stock: 4448S22P006S05 Datasheet
S22P006S05
Current Part
S22P006S05M2
TamuraIn Stock: 1024S22P006S05M2 Datasheet
S22P006S05M2
MFR Recommended

Key Parameters

Parameter Value
Sensor Type Hall Effect, Closed Loop
Current Sensing Range 6A
Number of Channels 1
Measurement Type AC/DC
Output Type Ratiometric, Voltage
Supply Voltage 5V
Frequency Response DC ~ 100kHz
Linearity ±0.2%
Response Time 1µs
Maximum Supply Current 12.5mA
Operating Temperature Range -10°C ~ 85°C
Polarization Bidirectional
Mounting Type Through Hole
Package Type Module
RoHS Status RoHS Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the S22P006S05 is determined by strict equivalence across the following critical parameters:

Electrical Equivalence Criteria:

  • Sensor Type: Hall Effect, Closed Loop
  • Current Sensing Capacity: 6A
  • Measurement Capability: AC/DC bidirectional
  • Output Configuration: Ratiometric voltage output
  • Supply Voltage: 5V
  • Frequency Response: DC ~ 100kHz minimum
  • Response Time: 1µs
  • Linearity: ±0.2%
  • Maximum Supply Current: 12.5mA

Mechanical Equivalence Criteria:

  • Mounting Type: Through Hole
  • Package Type: Module
  • Operating Temperature: -10°C ~ 85°C

Compliance Criteria:

  • RoHS Compliant status

The S22P006S05M2 meets all electrical, mechanical, and compliance requirements specified above, establishing it as a direct functional equivalent.

Parameter Comparison

Parameter S22P006S05 (Main Part) S22P006S05M2 (Substitute) Match Status
Manufacturer Tamura Tamura Identical
Sensor Type Hall Effect, Closed Loop Hall Effect, Closed Loop Identical
Current Sensing 6A 6A Identical
Number of Channels 1 1 Identical
Measurement Type AC/DC AC/DC Identical
Output Type Ratiometric, Voltage Ratiometric, Voltage Identical
Supply Voltage 5V 5V Identical
Frequency Response DC ~ 100kHz DC ~ 100kHz Identical
Linearity ±0.2% ±0.2% Identical
Response Time 1µs 1µs Identical
Maximum Supply Current 12.5mA 12.5mA Identical
Operating Temperature -10°C ~ 85°C -10°C ~ 85°C Identical
Polarization Bidirectional Bidirectional Identical
Mounting Type Through Hole Through Hole Identical
Package Type Module Module Identical
RoHS Status RoHS Compliant RoHS Compliant Identical
Product Status Obsolete Active Substitute is Active

Engineering Selection Recommendations

The S22P006S05M2 is the direct substitute for the obsolete S22P006S05. Both components are manufactured by Tamura and share identical electrical specifications, mechanical form factors, and compliance certifications.

Selection Basis:

The S22P006S05M2 maintains active product status, ensuring ongoing availability and supply chain continuity. Both parts are RoHS Compliant and carry identical ECCN (EAR99) and HTSUS (9030.33.3800) classifications, supporting regulatory and export compliance requirements.

All critical parameters—including Hall Effect closed-loop sensing architecture, 6A current measurement capacity, bidirectional AC/DC measurement, 5V supply operation, DC to 100kHz frequency response, ±0.2% linearity, 1µs response time, and through-hole module packaging—are identical between the main part and substitute.

For applications currently using the S22P006S05, direct replacement with the S22P006S05M2 requires no circuit modifications, design changes, or performance trade-offs.

Frequently Asked Questions (FAQ)

Q: Can the S22P006S05M2 directly replace the S22P006S05 without circuit modifications?

A: Yes. The S22P006S05M2 is electrically and mechanically identical to the S22P006S05. No circuit modifications, PCB layout changes, or firmware adjustments are required. The substitute part operates within identical voltage, current, frequency, and temperature parameters.

Q: Why is the S22P006S05 classified as obsolete?

A: The S22P006S05 has reached end-of-life status. The S22P006S05M2 represents the active continuation of this product line from Tamura, offering the same functional specifications with ongoing manufacturing and supply support.

Q: Are the through-hole mounting dimensions identical between both parts?

A: Both the S22P006S05 and S22P006S05M2 are specified as through-hole module packages. The provided parameters confirm identical mounting type and package classification. Consult the detailed mechanical drawings from Tamura to confirm specific pin pitch and dimensional tolerances for PCB layout verification.

Q: Do both parts support the same operating temperature range?

A: Yes. Both the S22P006S05 and S22P006S05M2 operate across the identical temperature range of -10°C to 85°C.

Q: What is the frequency response capability of these sensors?

A: Both parts support DC to 100kHz frequency response, enabling measurement of both steady-state and AC current signals within this bandwidth.

Q: Are there any compliance or regulatory differences between the two parts?

A: No. Both parts carry identical RoHS Compliant status, ECCN (EAR99), and HTSUS (9030.33.3800) classifications. No additional compliance documentation or regulatory review is required when substituting the S22P006S05M2 for the S22P006S05.

Q: What is the response time of these current sensors?

A: Both the S22P006S05 and S22P006S05M2 feature a 1µs response time, supporting fast transient current measurement and control loop applications.

Request Quote (Ships tomorrow)