Request Quote
(Ships tomorrow)
RY612024 General Purpose Relay SPDT 24VDC Equivalent & Substitute Parts
Part Overview
The RY612024 is an active general purpose relay manufactured by TE Connectivity Potter & Brumfield Relays. This component is a Single Pole Double Throw (SPDT) relay with a 24VDC coil, rated for 8A switching current, and designed for through-hole mounting on printed circuit boards. The relay features a fully sealed construction with silver nickel contact material and operates across an industrial temperature range of -40°C to 70°C.
Substitute parts are identified when equivalent electrical and mechanical parameters are maintained across coil voltage, contact form, current rating, switching voltage, operating characteristics, and physical mounting specifications. Identifying qualified substitutes ensures design flexibility and supply chain continuity while maintaining circuit performance and reliability.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Coil Voltage | 24VDC |
| Contact Form | SPDT (1 Form C) |
| Contact Rating (Current) | 8 A |
| Switching Voltage | 400VAC - Max |
| Mounting Type | Through Hole |
| Coil Current | 10.2 mA |
| Coil Type | Non Latching |
| Termination Style | PC Pin |
| Seal Rating | Sealed - Fully |
| Operating Temperature Range | -40°C ~ 70°C |
| Contact Material | Silver Nickel (AgNi) |
| Relay Type | General Purpose |
| Coil Resistance | 2.35 kOhms |
| Must Operate Voltage | 16.8 VDC |
| Must Release Voltage | 2.4 VDC |
| Operate Time | 9 ms |
| Release Time | 5 ms |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitute parts for the RY612024 are qualified based on strict equivalence across all critical electrical and mechanical parameters. The substitution logic is based on the following criteria:
Electrical Parameters: Coil voltage (24VDC), contact form (SPDT), contact current rating (8A), switching voltage (400VAC maximum), coil current (10.2 mA), coil resistance (2.35 kOhms), must operate voltage (16.8 VDC), must release voltage (2.4 VDC), and coil type (non-latching) must remain identical.
Mechanical Parameters: Mounting type (through-hole), termination style (PC pin), and seal rating (fully sealed) must be maintained.
Environmental Parameters: Operating temperature range (-40°C to 70°C), contact material (silver nickel), and relay type (general purpose) must be consistent.
Compliance Parameters: RoHS3 compliance, MSL rating (1), REACH unaffected status, and ECCN classification (EAR99) must be preserved.
Only parts meeting all these criteria are listed as direct substitutes.
Parameter Comparison
| Parameter | RY612024 | RY611024 |
|---|---|---|
| Manufacturer | TE Connectivity Potter & Brumfield Relays | TE Connectivity Potter & Brumfield Relays |
| Series | RY, SCHRACK | RY, SCHRACK |
| Product Status | Active | Active |
| Coil Voltage | 24VDC | 24VDC |
| Contact Form | SPDT (1 Form C) | SPDT (1 Form C) |
| Contact Rating (Current) | 8 A | 8 A |
| Switching Voltage | 400VAC - Max | 400VAC - Max |
| Mounting Type | Through Hole | Through Hole |
| Coil Current | 10.2 mA | 10.2 mA |
| Coil Type | Non Latching | Non Latching |
| Termination Style | PC Pin | PC Pin |
| Seal Rating | Sealed - Fully | Sealed - Fully |
| Operating Temperature | -40°C ~ 70°C | -40°C ~ 70°C |
| Contact Material | Silver Nickel (AgNi) | Silver Nickel (AgNi) |
| Relay Type | General Purpose | General Purpose |
| Coil Resistance | 2.35 kOhms | 2.35 kOhms |
| Must Operate Voltage | 16.8 VDC | 16.8 VDC |
| Must Release Voltage | 2.4 VDC | 2.4 VDC |
| Operate Time | 9 ms | 9 ms |
| Release Time | 5 ms | 5 ms |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
Engineering Selection Recommendations
Both the RY612024 and RY611024 are active products manufactured by TE Connectivity Potter & Brumfield Relays within the RY and SCHRACK series. Both components maintain identical electrical specifications, mechanical configurations, and compliance certifications.
Selection between these parts may be based on inventory availability and supply chain considerations. The RY611024 currently maintains higher inventory levels (9605 pieces) compared to the RY612024 (1126 pieces), which may influence procurement decisions for high-volume applications.
Both parts are ROHS3 compliant, REACH unaffected, and classified under ECCN EAR99, ensuring regulatory compliance for industrial and commercial applications. The MSL rating of 1 (unlimited) indicates no moisture sensitivity restrictions during storage or handling.
Frequently Asked Questions (FAQ)
Q: Can RY611024 be used as a direct replacement for RY612024?
A: Yes. The RY611024 is a parametric equivalent with identical electrical and mechanical specifications. All critical parameters including coil voltage, contact form, current rating, switching voltage, operating characteristics, and physical mounting are equivalent.
Q: Are there any differences in performance between RY612024 and RY611024?
A: No. Both relays operate with identical coil voltage (24VDC), contact current rating (8A), switching voltage (400VAC maximum), operate time (9 ms), release time (5 ms), and operating temperature range (-40°C to 70°C).
Q: Do both parts have the same through-hole mounting configuration?
A: Yes. Both RY612024 and RY611024 feature through-hole mounting with PC pin termination style, ensuring compatibility with standard printed circuit board layouts.
Q: Are compliance certifications identical for both parts?
A: Yes. Both parts are ROHS3 compliant, REACH unaffected, and carry the same ECCN classification (EAR99). MSL rating is 1 (unlimited) for both components.
Q: What is the difference between the base product numbers RY6120 and RY6110?
A: The base product numbers indicate different product lines within the RY series. However, the RY612024 and RY611024 maintain complete parametric equivalence across all specified electrical, mechanical, and environmental parameters.
Q: Can these relays be used in applications requiring 400VAC switching?
A: Yes. Both relays are rated for 400VAC maximum switching voltage and are suitable for AC switching applications within this voltage specification.
Q: What is the coil insulation rating for these relays?
A: Coil insulation specifications are not provided in the technical parameters for either component.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts