Equivalent & Substitute Parts Reference: RUW15SL24C

Part Overview

RUW15SL24C by Murata Power Solutions Inc. is an obsolete isolated DC-DC converter classified under the RUW15 series. The module supplies a regulated 24V output at a maximum current of 625mA and accepts a wide input voltage range of 16V to 160V. Key application areas include ITE (commercial) and railway. Its obsolete status necessitates the identification of compatible and equivalent substitute parts to ensure continuity in design and inventory management.

Substiute Parts

RUW15SL24C
Murata Power Solutions Inc.In Stock: 1109RUW15SL24C Datasheet
RUW15SL24C
Current Part
ERM01H110
ARTESYN / Advanced EnergyIn Stock: 1046ERM01H110 Datasheet
ERM01H110
MFR Recommended

Key Parameters

ParameterMain Part Value
ManufacturerMurata Power Solutions Inc.
Manufacturer Part NumberRUW15SL24C
SeriesRUW15 (15W)
DescriptionDC DC CONVERTER 24V 15W
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)16V
Voltage - Input (Max)160V
Voltage - Output 124V
Current - Output (Max)625mA
Power (Watts)15 W
Voltage - Isolation5 kV
FeaturesRemote On/Off, OTP, OVP, SCP
Operating Temperature-40°C ~ 85°C
Efficiency78.6%
Mounting TypeThrough Hole
Package / Case8-DIP Module
Size / Dimension2.00" L x 2.00" W x 0.79" H
Control FeaturesEnable, Active High
ApplicationsITE (Commercial), Railway
Product StatusObsolete
Inventory1034 Pcs New Original In Stock
ComplianceREACH Unaffected

Substitute Part Grouping Explanation

Substitute part selection is based on matching functional attributes, electrical ratings, mechanical form factor, and compliance parameters. The core substitution logic for RUW15SL24C includes:

  • Isolated module type
  • Output voltage: 24V
  • Output current rating
  • Wide input voltage range (must encompass or partially overlap 16V–160V)
  • Number of outputs: 1
  • Power rating
  • Package style (through hole module)
  • Application compatibility (e.g., railway)
  • Operating temperature range
  • Compliance and regulatory status

Parameter Comparison

Parameter Main Part (RUW15SL24C) Substitute (ERM01H110)
Manufacturer Murata Power Solutions Inc. ARTESYN / Advanced Energy
Series RUW15 (15W) ERM (20W)
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 16V 40V
Voltage - Input (Max) 160V 160V
Voltage - Output 1 24V 24V
Current - Output (Max) 625mA 833mA
Power (Watts) 15 W 20 W
Voltage - Isolation 5 kV 3 kV
Features Remote On/Off, OTP, OVP, SCP Remote On/Off, OCP, OTP, OVP
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C (With Derating)
Efficiency 78.6% 86%
Mounting Type Through Hole Through Hole
Package / Case 8-DIP Module 6-DIP Module
Size / Dimension 2.00" L x 2.00" W x 0.79" H 2.00" L x 1.00" W x 0.43" H
Applications ITE (Commercial), Railway Railway
Product Status Obsolete Active
Inventory 1034 Pcs 989 Pcs
Compliance REACH Unaffected RoHS Compliant

Engineering Selection Recommendations

Based strictly on the given product status and compliance data, RUW15SL24C is obsolete while ERM01H110 is active and RoHS compliant. Both parts specify inventory availability. For designs requiring active DC-DC converter modules in railway applications with 24V output, ERM01H110 fulfills compliance and certification parameters included in the input.

Frequently Asked Questions (FAQ)

Q1: What electrical parameters must be matched when substituting RUW15SL24C?
A1: Output voltage, input voltage range, output current, number of outputs, isolation voltage, mounting type, and operating temperature range.

Q2: Is the package style between RUW15SL24C and ERM01H110 compatible?
A2: Both use through-hole mounting but differ in DIP pin configuration and physical dimensions, which must be checked against board layout requirements.

Q3: Does ERM01H110 meet railway application criteria?
A3: ERM01H110 is listed for railway applications in the provided parameters.

Q4: How does the compliance and product status affect substitution?
A4: RUW15SL24C is obsolete whereas ERM01H110 is active and RoHS compliant, making ERM01H110 suitable for designs needing current regulatory compliance and supply continuity.

Q5: Are control features and protections directly comparable between the two parts?
A5: Both include remote On/Off and multiple protection features, as explicitly listed in the input data.