Part Overview

The Recom Power RTS-0512/H is an isolated DC-DC converter module, providing a single 12V output at up to 167mA with 2W rated power. Its input voltage range is 4.5V to 5.5V. The module includes 3 kV isolation, SCP protection, is designed for ITE (Commercial) and Medical applications, and operates in the -40°C to +85°C range. This product is Obsolete; therefore, identifying substitute models is crucial to maintain supply continuity in designs that specify RTS-0512/H.

Substiute Parts

RTS-0512/H
Recom PowerIn Stock: 899RTS-0512/H Datasheet
RTS-0512/H
Current Part
R2S-0512/H
Recom PowerIn Stock: 1394R2S-0512/H Datasheet
R2S-0512/H
Direct

Key Parameters

ParameterValue
Manufacturer Part NumberRTS-0512/H
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)4.5V
Voltage - Input (Max)5.5V
Voltage - Output 112V
Current - Output (Max)167mA
Power (Watts)2 W
Voltage - Isolation3 kV
ApplicationsITE (Commercial), Medical
FeaturesSCP
Operating Temperature-40°C ~ 85°C
Efficiency85%
Mounting TypeSurface Mount
Package / Case8-SMD Module, 5 Leads
Size / Dimension0.50" L x 0.37" W x 0.35" H (12.8mm x 9.3mm x 9.0mm)
RoHS StatusROHS3 Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)
REACH StatusREACH Unaffected

Substitute Part Grouping Explanation

Substitution for the RTS-0512/H DC-DC converter considers absolute matching of the following parameters:

  • Isolated module type
  • Number of outputs (1)
  • Output voltage (12V) and output current (167mA max)
  • Input voltage range (4.5V to 5.5V)
  • Rated power (2W)
  • Isolation voltage (3 kV)
  • Applications (ITE, Medical)
  • Features (SCP)
  • Mounting type (Surface Mount)
  • Package/case (8-SMD Module, 5 Leads)
  • Environmental ratings (operating temperature, RoHS, REACH, MSL)

Parts are grouped as substitutes if every listed parameter is equivalent or exceeds the requirement without deviation.

Parameter Comparison

Parameter RTS-0512/H R2S-0512/H
Manufacturer Recom Power Recom Power
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 4.5V 4.5V
Voltage - Input (Max) 5.5V 5.5V
Voltage - Output 1 12V 12V
Current - Output (Max) 167mA 167mA
Power (Watts) 2 W 2 W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial), Medical ITE (Commercial), Medical
Features SCP SCP
Operating Temperature -40°C ~ 85°C -40°C ~ 100°C
Efficiency 85% 85%
Mounting Type Surface Mount Surface Mount
Package / Case 8-SMD Module, 5 Leads 8-SMD Module, 5 Leads
Size / Dimension 0.50" L x 0.37" W x 0.35" H (12.8mm x 9.3mm x 9.0mm) 0.50" L x 0.42" W x 0.35" H (12.8mm x 10.7mm x 9.0mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

RTS-0512/H is classified as Obsolete. The R2S-0512/H matches or exceeds all electrical and mechanical parameters required for direct substitution, including RoHS3 and REACH compliance, and shares the same ECCN and MSL classifications. Refer to the package size differences when addressing board layout compatibility.

Frequently Asked Questions (FAQ)

Q1: How is R2S-0512/H selected as a substitute for RTS-0512/H?
A1: R2S-0512/H matches all key operational parameters: voltage, current, power, isolation rating, mounting style, and compliance attributes. Selection is solely based on matching explicit specifications.

Q2: Are the output and input voltage ratings identical between RTS-0512/H and R2S-0512/H?
A2: Yes, both parts provide a 12V output with 4.5V to 5.5V input voltage specification.

Q3: Is the package compatible for surface mount assembly?
A3: Both parts utilize the 8-SMD Module, 5 Leads surface mount package; the R2S-0512/H is slightly wider but maintains the same length and height.

Q4: Are the environmental and compliance ratings equivalent?
A4: Both RTS-0512/H and R2S-0512/H are ROHS3 Compliant, have MSL 1, and are REACH Unaffected.

Q5: Does the substitute meet the same application requirements (ITE, Medical)?
A5: Yes, both parts list applicability for ITE (Commercial) and Medical use cases.

Request Quote (Ships tomorrow)