Request Quote
(Ships tomorrow)
RTD-2415/HP Equivalent & Substitute Parts Reference
Part Overview
RTD-2415/HP by Recom Power is an isolated module DC-DC converter designed to provide dual outputs of +15V and -15V at 66mA each, with a total power output of 2W, supporting input voltages from 21.6V to 26.4V. This product is classified as obsolete, necessitating the identification of substitute models to fulfill application requirements in ITE (Commercial) and Medical sectors. The need for substitution arises due to the discontinued status of this part, requiring engineers to select functionally equivalent alternatives.
Substiute Parts
Key Parameters
| Parameter | RTD-2415/HP Value |
|---|---|
| Manufacturer | Recom Power |
| Category | |
| Type | Isolated Module |
| Number of Outputs | 2 |
| Voltage - Input (Min) | 21.6V |
| Voltage - Input (Max) | 26.4V |
| Voltage - Output 1 | 15V |
| Voltage - Output 2 | -15V |
| Current - Output (Max) | 66mA, 66mA |
| Power (Watts) | 2 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial), Medical |
| Features | SCP |
| Operating Temperature | -40°C ~ 85°C |
| Efficiency | 85% |
| Mounting Type | Surface Mount |
| Package / Case | 10-SMD Module, 6 Leads |
| Size / Dimension | 0.60" L x 0.37" W x 0.35" H (15.2mm x 9.3mm x 9.0mm) |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution for RTD-2415/HP is established exclusively on matching electrical and mechanical parameters, including input voltage range, output voltages and currents, total power rating, voltage isolation, mounting type, package dimensions, thermal rating, compliance status, and application suitability. Only parts that strictly adhere to these criteria are included as substitutes.
Parameter Comparison
| Parameter | RTD-2415/HP | R2D-2415/HP |
|---|---|---|
| Manufacturer | Recom Power | Recom Power |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 2 | 2 |
| Voltage - Input (Min) | 21.6V | 21.6V |
| Voltage - Input (Max) | 26.4V | 26.4V |
| Voltage - Output 1 | 15V | 15V |
| Voltage - Output 2 | -15V | -15V |
| Current - Output (Max) | 66mA, 66mA | 66mA, 66mA |
| Power (Watts) | 2 W | 2 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial), Medical | ITE (Commercial), Medical |
| Features | SCP | SCP |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 100°C |
| Efficiency | 85% | 85% |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | 10-SMD Module, 6 Leads | 10-SMD Module, 6 Leads |
| Size / Dimension | 0.60" L x 0.37" W x 0.35" H (15.2mm x 9.3mm x 9.0mm) | 0.60" L x 0.42" W x 0.35" H (15.2mm x 10.7mm x 9.0mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
Selection is determined by matching product status, RoHS (ROHS3) compliance, REACH status, moisture sensitivity level (MSL 1), and export control classification (ECCN: EAR99). Substitutes must be active and meet all relevant compliance and certification parameters provided.
Frequently Asked Questions (FAQ)
Q1: What are the electrical criteria for substituting RTD-2415/HP?
A1: Substitute parts require matching input voltage range, output voltages, output currents, and power rating. Isolation voltage must also be equivalent.
Q2: How critical is package compatibility in selecting a substitute?
A2: Mechanical compatibility is assured by identical mounting type and similar package/case specifications. Slight dimensional variations should be considered based on the provided package parameters.
Q3: Are compliance statuses for RoHS and REACH sufficient for direct replacement?
A3: All listed substitutes match the provided RoHS and REACH compliance information.
Q4: Is the substitute part suitable for ITE (Commercial) and Medical applications?
A4: Compatibility with ITE (Commercial) and Medical applications is indicated in the provided specifications for both the part and its substitute.
Q5: How does operating temperature affect substitution?
A5: Substitute parts provide an equal or wider operating temperature range relative to RTD-2415/HP, as specified.
Q6: Are output parameters affected by dimension differences in substitutes?
A6: Substitute parts match output voltage and current ratings based strictly on the provided parameters.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts