Request Quote
(Ships tomorrow)
RTD-2412 Equivalent & Substitute Parts
Part Overview
The RTD-2412 is an isolated module DC-DC converter manufactured by Recom Power, designed to convert a 21.6V to 26.4V input to dual outputs of +12V and -12V at 83mA each, delivering 2W of power. This component is classified as obsolete, which necessitates identification of active equivalent alternatives for new designs and ongoing production requirements. The RTD-2412 operates across a temperature range of -40°C to 85°C and is suitable for ITE (Commercial) applications with short-circuit protection features.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Recom Power |
| Input Voltage Range | 21.6V – 26.4V |
| Output Configuration | +12V / -12V (Dual Output) |
| Output Current (Max) | 83mA per output |
| Power Rating | 2W |
| Isolation Voltage | 1 kV |
| Mounting Type | Surface Mount |
| Package Type | 10-SMD Module, 6 Leads |
| Operating Temperature | -40°C to 85°C |
| Efficiency | 83% |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution of the RTD-2412 is determined by strict equivalence across the following critical parameters:
Electrical Compatibility Requirements:
- Input voltage range: 21.6V – 26.4V
- Output voltage levels: +12V and -12V
- Output current capacity: 83mA minimum per output
- Power rating: 2W
- Isolation voltage: 1 kV
- Efficiency: 83%
Mechanical Compatibility Requirements:
- Mounting type: Surface Mount
- Package configuration: 10-SMD Module, 6 Leads
- Physical dimensions compatible with PCB layout constraints
Regulatory & Compliance Requirements:
- RoHS3 compliance
- REACH unaffected status
- Moisture sensitivity level: 1 (Unlimited)
The R2D-2412 meets all electrical and mechanical substitution criteria while offering improved product status and extended operating temperature range.
Parameter Comparison
| Parameter | RTD-2412 (Obsolete) | R2D-2412 (Active) | Compatibility |
|---|---|---|---|
| Manufacturer | Recom Power | Recom Power | Identical |
| Input Voltage (Min) | 21.6V | 21.6V | Identical |
| Input Voltage (Max) | 26.4V | 26.4V | Identical |
| Output 1 Voltage | +12V | +12V | Identical |
| Output 2 Voltage | -12V | -12V | Identical |
| Output Current (Max) | 83mA, 83mA | 83mA, 83mA | Identical |
| Power Rating | 2W | 2W | Identical |
| Isolation Voltage | 1 kV | 1 kV | Identical |
| Features | SCP | SCP | Identical |
| Mounting Type | Surface Mount | Surface Mount | Identical |
| Package / Case | 10-SMD Module, 6 Leads | 10-SMD Module, 6 Leads | Identical |
| Operating Temperature | -40°C to 85°C | -40°C to 100°C | R2D-2412 extends upper limit |
| Efficiency | 83% | 83% | Identical |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | Identical |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) | Identical |
| Product Status | Obsolete | Active | R2D-2412 actively manufactured |
| Packaging | Not specified | Tube | R2D-2412 in standard tube packaging |
Engineering Selection Recommendations
The R2D-2412 is the direct substitute for the RTD-2412 based on the following engineering criteria:
Product Status Consideration: The RTD-2412 is classified as obsolete, indicating discontinued manufacturing and limited availability. The R2D-2412 maintains active product status with confirmed inventory of 1122 pieces, ensuring supply chain continuity and long-term component availability.
Electrical Equivalence: All critical electrical parameters are identical between the two parts: input voltage range, output voltage levels, output current capacity, power rating, isolation voltage, and efficiency. These parameters determine functional compatibility in the application circuit.
Thermal Performance Enhancement: The R2D-2412 extends the maximum operating temperature from 85°C to 100°C, providing improved thermal margin for applications operating in elevated ambient conditions or with higher component density on the PCB.
Regulatory Compliance: Both parts maintain ROHS3 compliance and REACH unaffected status, ensuring compatibility with current environmental and regulatory requirements. Moisture sensitivity level remains at 1 (Unlimited) for both variants.
Mechanical Compatibility: Package configuration, mounting type, and lead count are identical, enabling direct PCB layout compatibility without redesign requirements.
Frequently Asked Questions (FAQ)
Q: Can the R2D-2412 be used as a direct replacement for the RTD-2412 in existing designs?
A: Yes. The R2D-2412 is electrically and mechanically equivalent to the RTD-2412. All critical parameters including input voltage range, output voltages, output current capacity, power rating, isolation voltage, and package configuration are identical. Direct substitution is supported without circuit modification.
Q: What is the primary difference between the RTD-2412 and R2D-2412?
A: The primary differences are product status and operating temperature range. The RTD-2412 is obsolete with a maximum operating temperature of 85°C, while the R2D-2412 is actively manufactured with an extended maximum operating temperature of 100°C. The R2D-2412 also specifies tube packaging.
Q: Are there any dimensional differences between these parts?
A: Minor dimensional variation exists in the width specification. The RTD-2412 measures 0.37" W (9.3mm), while the R2D-2412 measures 0.42" W (10.7mm). Length and height remain identical at 0.60" L × 0.35" H (15.2mm × 9.0mm). PCB layout verification is recommended to confirm clearance compatibility.
Q: Do both parts meet the same regulatory requirements?
A: Yes. Both the RTD-2412 and R2D-2412 are ROHS3 compliant, REACH unaffected, and carry identical moisture sensitivity level ratings of 1 (Unlimited). Regulatory compliance is equivalent between the two parts.
Q: What is the significance of the active product status for the R2D-2412?
A: Active product status indicates ongoing manufacturing and distribution by Recom Power. This ensures component availability for new production orders, spare parts procurement, and design revisions. The RTD-2412's obsolete status limits availability to existing inventory only.
Q: Are the output current ratings identical for both parts?
A: Yes. Both the RTD-2412 and R2D-2412 deliver 83mA maximum current on the +12V output and 83mA maximum current on the -12V output, providing identical load capacity for dual-rail applications.
Q: Can the extended temperature range of the R2D-2412 affect circuit performance?
A: The extended temperature range of the R2D-2412 (-40°C to 100°C versus -40°C to 85°C) represents improved thermal capability and does not negatively affect circuit performance. Applications operating within the RTD-2412's original temperature range will experience identical performance with the R2D-2412.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts