RTD-2412 Equivalent & Substitute Parts

Part Overview

The RTD-2412 is an isolated module DC-DC converter manufactured by Recom Power, designed to convert a 21.6V to 26.4V input to dual outputs of +12V and -12V at 83mA each, delivering 2W of power. This component is classified as obsolete, which necessitates identification of active equivalent alternatives for new designs and ongoing production requirements. The RTD-2412 operates across a temperature range of -40°C to 85°C and is suitable for ITE (Commercial) applications with short-circuit protection features.

Substiute Parts

RTD-2412
Recom PowerIn Stock: 1069RTD-2412 Datasheet
RTD-2412
Current Part
R2D-2412
Recom PowerIn Stock: 1179R2D-2412 Datasheet
R2D-2412
Direct

Key Parameters

Parameter Value
Manufacturer Recom Power
Input Voltage Range 21.6V – 26.4V
Output Configuration +12V / -12V (Dual Output)
Output Current (Max) 83mA per output
Power Rating 2W
Isolation Voltage 1 kV
Mounting Type Surface Mount
Package Type 10-SMD Module, 6 Leads
Operating Temperature -40°C to 85°C
Efficiency 83%
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution of the RTD-2412 is determined by strict equivalence across the following critical parameters:

Electrical Compatibility Requirements:

  • Input voltage range: 21.6V – 26.4V
  • Output voltage levels: +12V and -12V
  • Output current capacity: 83mA minimum per output
  • Power rating: 2W
  • Isolation voltage: 1 kV
  • Efficiency: 83%

Mechanical Compatibility Requirements:

  • Mounting type: Surface Mount
  • Package configuration: 10-SMD Module, 6 Leads
  • Physical dimensions compatible with PCB layout constraints

Regulatory & Compliance Requirements:

  • RoHS3 compliance
  • REACH unaffected status
  • Moisture sensitivity level: 1 (Unlimited)

The R2D-2412 meets all electrical and mechanical substitution criteria while offering improved product status and extended operating temperature range.

Parameter Comparison

Parameter RTD-2412 (Obsolete) R2D-2412 (Active) Compatibility
Manufacturer Recom Power Recom Power Identical
Input Voltage (Min) 21.6V 21.6V Identical
Input Voltage (Max) 26.4V 26.4V Identical
Output 1 Voltage +12V +12V Identical
Output 2 Voltage -12V -12V Identical
Output Current (Max) 83mA, 83mA 83mA, 83mA Identical
Power Rating 2W 2W Identical
Isolation Voltage 1 kV 1 kV Identical
Features SCP SCP Identical
Mounting Type Surface Mount Surface Mount Identical
Package / Case 10-SMD Module, 6 Leads 10-SMD Module, 6 Leads Identical
Operating Temperature -40°C to 85°C -40°C to 100°C R2D-2412 extends upper limit
Efficiency 83% 83% Identical
RoHS Status ROHS3 Compliant ROHS3 Compliant Identical
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited) Identical
Product Status Obsolete Active R2D-2412 actively manufactured
Packaging Not specified Tube R2D-2412 in standard tube packaging

Engineering Selection Recommendations

The R2D-2412 is the direct substitute for the RTD-2412 based on the following engineering criteria:

Product Status Consideration: The RTD-2412 is classified as obsolete, indicating discontinued manufacturing and limited availability. The R2D-2412 maintains active product status with confirmed inventory of 1122 pieces, ensuring supply chain continuity and long-term component availability.

Electrical Equivalence: All critical electrical parameters are identical between the two parts: input voltage range, output voltage levels, output current capacity, power rating, isolation voltage, and efficiency. These parameters determine functional compatibility in the application circuit.

Thermal Performance Enhancement: The R2D-2412 extends the maximum operating temperature from 85°C to 100°C, providing improved thermal margin for applications operating in elevated ambient conditions or with higher component density on the PCB.

Regulatory Compliance: Both parts maintain ROHS3 compliance and REACH unaffected status, ensuring compatibility with current environmental and regulatory requirements. Moisture sensitivity level remains at 1 (Unlimited) for both variants.

Mechanical Compatibility: Package configuration, mounting type, and lead count are identical, enabling direct PCB layout compatibility without redesign requirements.

Frequently Asked Questions (FAQ)

Q: Can the R2D-2412 be used as a direct replacement for the RTD-2412 in existing designs?

A: Yes. The R2D-2412 is electrically and mechanically equivalent to the RTD-2412. All critical parameters including input voltage range, output voltages, output current capacity, power rating, isolation voltage, and package configuration are identical. Direct substitution is supported without circuit modification.

Q: What is the primary difference between the RTD-2412 and R2D-2412?

A: The primary differences are product status and operating temperature range. The RTD-2412 is obsolete with a maximum operating temperature of 85°C, while the R2D-2412 is actively manufactured with an extended maximum operating temperature of 100°C. The R2D-2412 also specifies tube packaging.

Q: Are there any dimensional differences between these parts?

A: Minor dimensional variation exists in the width specification. The RTD-2412 measures 0.37" W (9.3mm), while the R2D-2412 measures 0.42" W (10.7mm). Length and height remain identical at 0.60" L × 0.35" H (15.2mm × 9.0mm). PCB layout verification is recommended to confirm clearance compatibility.

Q: Do both parts meet the same regulatory requirements?

A: Yes. Both the RTD-2412 and R2D-2412 are ROHS3 compliant, REACH unaffected, and carry identical moisture sensitivity level ratings of 1 (Unlimited). Regulatory compliance is equivalent between the two parts.

Q: What is the significance of the active product status for the R2D-2412?

A: Active product status indicates ongoing manufacturing and distribution by Recom Power. This ensures component availability for new production orders, spare parts procurement, and design revisions. The RTD-2412's obsolete status limits availability to existing inventory only.

Q: Are the output current ratings identical for both parts?

A: Yes. Both the RTD-2412 and R2D-2412 deliver 83mA maximum current on the +12V output and 83mA maximum current on the -12V output, providing identical load capacity for dual-rail applications.

Q: Can the extended temperature range of the R2D-2412 affect circuit performance?

A: The extended temperature range of the R2D-2412 (-40°C to 100°C versus -40°C to 85°C) represents improved thermal capability and does not negatively affect circuit performance. Applications operating within the RTD-2412's original temperature range will experience identical performance with the R2D-2412.

Request Quote (Ships tomorrow)