Request Quote
(Ships tomorrow)
RTD-1224 Equivalent & Substitute Parts Reference
Part Overview
The Recom Power RTD-1224 is an isolated DC-DC converter module in the ECONOLINE RTD series with dual outputs (+24V and -24V) at 2W total power. This surface mount converter accepts 10.8V to 13.2V input and delivers a maximum output current of 42mA per channel. As this DC-DC converter is classified as Obsolete, it is essential for engineers requiring ongoing assembly or repair support to identify direct substitute models matching the significant electrical, mechanical, and compliance criteria specified.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | RTD-1224 |
| Series | ECONOLINE RTD (2W) |
| Type | Isolated Module |
| Mounting Type | Surface Mount |
| Package / Case | 10-SMD Module, 6 Leads |
| Number of Outputs | 2 |
| Voltage - Input (Min) | 10.8V |
| Voltage - Input (Max) | 13.2V |
| Voltage - Output 1 | 24V |
| Voltage - Output 2 | -24V |
| Current - Output (Max) | 42mA, 42mA |
| Power (Watts) | 2 W |
| Voltage - Isolation | 1 kV |
| Operating Temperature | -40°C ~ 85°C |
| Efficiency | 85% |
| Features | SCP |
| Size / Dimension | 0.60" L x 0.37" W x 0.35" H (15.2mm x 9.3mm x 9.0mm) |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| Applications | ITE (Commercial) |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitution is based strictly on the following parameters: device type (Isolated Module), input voltage range (10.8V to 13.2V), dual output configuration (+24V/-24V, 42mA each), total output power (2W), voltage isolation (1 kV), efficiency, surface mount package (10-SMD Module, 6 Leads), identical or highly similar package dimensions, features (SCP), RoHS compliance, moisture sensitivity level, and application class. Only parts matching or exceeding these criteria are categorized as direct substitutes.
Parameter Comparison
| Parameter | RTD-1224 | R2D-1224 |
|---|---|---|
| Manufacturer | Recom Power | Recom Power |
| Series | ECONOLINE RTD (2W) | ECONOLINE R2D (2W) |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 2 | 2 |
| Voltage - Input (Min) | 10.8V | 10.8V |
| Voltage - Input (Max) | 13.2V | 13.2V |
| Voltage - Output 1 | 24V | 24V |
| Voltage - Output 2 | -24V | -24V |
| Current - Output (Max) | 42mA, 42mA | 42mA, 42mA |
| Power (Watts) | 2 W | 2 W |
| Voltage - Isolation | 1 kV | 1 kV |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 100°C |
| Efficiency | 85% | 85% |
| Features | SCP | SCP |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | 10-SMD Module, 6 Leads | 10-SMD Module, 6 Leads |
| Size / Dimension | 0.60" L x 0.37" W x 0.35" H (15.2mm x 9.3mm x 9.0mm) | 0.60" L x 0.42" W x 0.35" H (15.2mm x 10.7mm x 9.0mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
The Recom Power R2D-1224 is a direct substitute for the RTD-1224 based on matching input voltage, output configuration, power rating, isolation, surface mount package style, RoHS compliance, moisture sensitivity level, and REACH status. R2D-1224 is in Active status and maintains compliance with the relevant certifications provided. All substitutions adhere strictly to the listed parameters.
Frequently Asked Questions (FAQ)
Q1: What criteria are used to determine if R2D-1224 is a substitute for RTD-1224?
A1: Substitution is based solely on matching electrical specifications (input/output voltage, current, power, isolation), package type, mounting type, certifications, and compliance parameters.
Q2: Is the mechanical package identical between RTD-1224 and R2D-1224?
A2: Both parts use a 10-SMD Module, 6 Leads package and have matching height and length; the R2D-1224 is slightly wider (0.42" vs 0.37").
Q3: Are there differences in compliance or certifications?
A3: Both RTD-1224 and R2D-1224 are ROHS3 Compliant, have MSL 1 (Unlimited), and are REACH Unaffected.
Q4: Are both products suitable for the same technical applications?
A4: Both are categorized for ITE (Commercial) applications and include SCP features as stated in the provided parameters.
Q5: Why is substitution necessary for RTD-1224?
A5: Substitution is required due to the Obsolete status of RTD-1224, necessitating a direct alternative for ongoing designs and repairs.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts