Request Quote
(Ships tomorrow)
RTD-1205/H Equivalent & Substitute Parts Reference
Part Overview
The RTD-1205/H from Recom Power is an isolated DC-DC converter module delivering ±5V outputs at 200mA each, with an input voltage range of 10.8V to 13.2V and a rated output power of 2W. It is supplied in a 10-SMD module with 6 leads and supports operating temperatures from -40°C to 85°C. The product status is Obsolete, making alternative models essential for ensuring continued design support, maintenance, or stock replenishment in existing applications where identical electrical and mechanical performance is required.
Substiute Parts
Key Parameters
| Parameter | RTD-1205/H Value |
|---|---|
| Manufacturer | Recom Power |
| Number of Outputs | 2 |
| Voltage - Input (Min) | 10.8V |
| Voltage - Input (Max) | 13.2V |
| Voltage - Output 1 | 5V |
| Voltage - Output 2 | -5V |
| Current - Output (Max) | 200mA, 200mA |
| Power (Watts) | 2 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial), Medical |
| Operating Temperature | -40°C ~ 85°C |
| Features | SCP |
| Mounting Type | Surface Mount |
| Package / Case | 10-SMD Module, 6 Leads |
| Size / Dimension | 0.60" L x 0.37" W x 0.35" H (15.2mm x 9.3mm x 9.0mm) |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute DC-DC converter modules are grouped based on strict matching of key electrical and mechanical parameters. These parameters include manufacturer, number of outputs, input voltage range, output voltages, maximum output current, output power, isolation voltage, intended applications, operating temperature, feature set, mounting type, package/case, physical dimensions, RoHS status, MSL, REACH status, ECCN, and HTSUS code. Only modules meeting all listed criteria are considered equivalents within the constraints of this product category.
Parameter Comparison
| Parameter | RTD-1205/H | R2D-1205/H |
|---|---|---|
| Manufacturer | Recom Power | Recom Power |
| Number of Outputs | 2 | 2 |
| Voltage - Input (Min) | 10.8V | 10.8V |
| Voltage - Input (Max) | 13.2V | 13.2V |
| Voltage - Output 1 | 5V | 5V |
| Voltage - Output 2 | -5V | -5V |
| Current - Output (Max) | 200mA, 200mA | 200mA, 200mA |
| Power (Watts) | 2 W | 2 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial), Medical | ITE (Commercial), Medical |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 100°C |
| Features | SCP | SCP |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | 10-SMD Module, 6 Leads | 10-SMD Module, 6 Leads |
| Size / Dimension | 0.60" L x 0.37" W x 0.35" H (15.2mm x 9.3mm x 9.0mm) | 0.60" L x 0.42" W x 0.35" H (15.2mm x 10.7mm x 9.0mm) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
The RTD-1205/H is classified as Obsolete. For regulatory compliance, certifications, and continuous supply, selecting the R2D-1205/H is validated by its Active status, equivalent RoHS3 compliance, MSL, REACH status, ECCN, and matching HTSUS. Only officially listed substitute part numbers should be used as direct replacements.
Frequently Asked Questions (FAQ)
Q1: What defines an electrical equivalent DC-DC converter in this category?
A1: Electrical equivalency is defined by matching numbers of outputs, input voltage range, output voltages and currents, output power, isolation voltage, applications, and feature set.
Q2: Can the R2D-1205/H be used in the same PCB location as the RTD-1205/H?
A2: The mounting type and package/case are both 10-SMD module, 6 leads. Physical size differs slightly in width (0.37" vs. 0.42"); both are surface-mountable.
Q3: Does the R2D-1205/H maintain required certifications?
A3: The R2D-1205/H maintains ROHS3 compliance, MSL 1 (unlimited), and REACH unaffected status with the same ECCN and HTSUS as the RTD-1205/H.
Q4: Is there any difference in temperature operation range?
A4: The R2D-1205/H supports a wider operating temperature range of -40°C to 100°C, compared to -40°C to 85°C for the RTD-1205/H.
Q5: Is the feature set (such as SCP) retained in the substitute?
A5: Yes, both the RTD-1205/H and R2D-1205/H list SCP as a feature, according to the provided data.
Q6: Are inventory conditions similar for available substitute parts?
A6: Inventory information is listed for both parts; verify current stock levels as per organizational logistics.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts