RSS-3.312/P Equivalent & Substitute Parts Reference

Part Overview

The Recom Power RSS-3.312/P is an isolated module DC-DC converter designed to convert DC input voltages between 3V and 3.6V to a single 12V output at a maximum current of 84mA with an output power of 1W. The unit provides 1kV isolation and features short-circuit protection (SCP). It is built for surface mounting, with a compact 8-SMD package and is intended for ITE (commercial) applications. The RSS-3.312/P is classified as obsolete, making it necessary to identify alternative, functionally equivalent models to ensure ongoing supply and design continuity.

Substiute Parts

RSS-3.312/P
Recom PowerIn Stock: 796RSS-3.312/P Datasheet
RSS-3.312/P
Current Part
R1S-3.312/P
Recom PowerIn Stock: 1194R1S-3.312/P Datasheet
R1S-3.312/P
Direct

Key Parameters

Parameter RSS-3.312/P
Manufacturer Recom Power
Type Isolated Module
Input Voltage Range 3V - 3.6V
Number of Outputs 1
Output Voltage 12V
Max Output Current 84mA
Output Power 1W
Isolation Voltage 1 kV
Features SCP
Operating Temperature -40°C ~ 85°C
Efficiency 80%
Mounting Type Surface Mount
Package / Case 8-SMD Module, 5 Leads
Size / Dimension 0.50" L x 0.32" W x 0.29" H (12.8mm x 8.2mm x 7.3mm)
RoHS Status ROHS3 Compliant
MSL 1 (Unlimited)
REACH Status REACH Unaffected

Substitute Part Grouping Explanation

Substitutes for the RSS-3.312/P are determined strictly by matching the following parameters: input voltage range (3V - 3.6V), output voltage (12V), maximum output current (84mA), output power (1W), number of outputs (1), isolation voltage (1kV), features (SCP), mounting type (surface mount), and compliance (ROHS3, REACH). The substitute must be an isolated module in a compatible surface-mount package with equivalent or better operating temperature, efficiency, and other listed features.

Parameter Comparison

Parameter RSS-3.312/P R1S-3.312/P
Manufacturer Recom Power Recom Power
Description DC DC CONVERTER 12V 1W DC DC CONVERTER 12V 1W
Type Isolated Module Isolated Module
Number of Outputs 1 1
Input Voltage Min 3V 3V
Input Voltage Max 3.6V 3.6V
Output Voltage 1 12V 12V
Max Output Current 84mA 84mA
Power (Watts) 1 W 1 W
Isolation Voltage 1 kV 1 kV
Features SCP SCP
Operating Temperature -40°C ~ 85°C -40°C ~ 100°C
Efficiency 80% 80%
Mounting Type Surface Mount Surface Mount
Package / Case 8-SMD Module, 5 Leads 8-SMD Module, 5 Leads
Size / Dimension 0.50" L x 0.32" W x 0.29" H (12.8mm x 8.2mm x 7.3mm) 0.50" L x 0.42" W x 0.28" H (12.8mm x 10.7mm x 7.0mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
MSL 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

The RSS-3.312/P is classified as obsolete. The R1S-3.312/P from Recom Power is an active product, meeting all critical electrical, mechanical, and compliance parameters including ROHS3 and REACH. Both parts provide the required moisture sensitivity level (MSL 1 - Unlimited). No variations in product status, compliance, or certifications are present between the parts that would restrict direct substitution.

Frequently Asked Questions (FAQ)

Q1: What are the essential criteria for selecting equivalent DC-DC converter substitutes?
A1: Essential criteria include matching input voltage range (3V - 3.6V), output voltage (12V), maximum output current (84mA), output power (1W), isolation voltage (1kV), number of outputs, mounting type, features, and RoHS/REACH compliance status.

Q2: Are there any differences in package dimensions between the RSS-3.312/P and R1S-3.312/P?
A2: Both parts share the same package type (8-SMD Module, 5 Leads) but have minor differences in width and height. Confirm fit within the intended PCB footprint and enclosure.

Q3: Is the substitute part compatible in terms of environmental and compliance certifications?
A3: Yes, both the RSS-3.312/P and the R1S-3.312/P are ROHS3 compliant and REACH unaffected.

Q4: Can the R1S-3.312/P be used in applications previously qualified for the RSS-3.312/P?
A4: All relevant parameters required for functional equivalence are matched or exceeded, including isolation, efficiency, and operating temperature range.

Q5: How does the product status affect engineering selection?
A5: RSS-3.312/P is obsolete; R1S-3.312/P is active. Selection of an active product ensures supply continuity.

Request Quote (Ships tomorrow)