Recom Power RSS-1512/HP Equivalent & Substitute Parts Reference

Part Overview

The Recom Power RSS-1512/HP is an isolated module DC-DC converter, providing 12V output at up to 84mA with 3 kV isolation. It is designed for commercial IT equipment and medical applications. This part is marked as obsolete, making it necessary to identify alternative models that match its electrical and mechanical specifications for continued support and replacement in existing designs.

Substiute Parts

RSS-1512/HP
Recom PowerIn Stock: 1103RSS-1512/HP Datasheet
RSS-1512/HP
Current Part
R1S-1512/HP
Recom PowerIn Stock: 917R1S-1512/HP Datasheet
R1S-1512/HP
Direct

Key Parameters

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status MSL REACH Status ECCN HTSUS
RSS-1512/HP Recom Power ECONOLINE RSS (1W) Obsolete Isolated Module 1 13.5V 16.5V 12V 84mA 1 W 3 kV ITE (Commercial), Medical SCP -40°C ~ 85°C 80% Surface Mount 8-SMD Module, 5 Leads 0.50" L x 0.32" W x 0.29" H (12.8mm x 8.2mm x 7.3mm) ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580

Substitute Part Grouping Explanation

Substitution is based strictly on matching electrical and mechanical parameters. Allowed substitutes are those that provide identical or highly comparable input voltage range, output voltage and current, power rating, output isolation, mounting type, package form, temperature range, efficiency, certifications, and compliance status. These parameters are critical in ensuring electrical, thermal, and regulatory compatibility.

Key parameters for substitution:

  • Input voltage range (13.5V to 16.5V)
  • Output voltage (12V)
  • Maximum output current (84mA)
  • Power rating (1W)
  • Isolation voltage (3 kV)
  • Application suitability (ITE, Medical)
  • Features (SCP)
  • Operating temperature range
  • Mounting type (Surface Mount)
  • Package / Case (8-SMD Module, 5 Leads)
  • Compliance (RoHS3, REACH)
  • Size / Dimension

Parameter Comparison

Parameter RSS-1512/HP R1S-1512/HP
Manufacturer Recom Power Recom Power
Description DC DC CONVERTER 12V 1W DC DC CONVERTER 12V 1W
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 13.5V 13.5V
Voltage - Input (Max) 16.5V 16.5V
Voltage - Output 1 12V 12V
Current - Output (Max) 84mA 84mA
Power (Watts) 1 W 1 W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial), Medical ITE (Commercial), Medical
Features SCP SCP
Operating Temperature -40°C ~ 85°C -40°C ~ 100°C
Efficiency 80% 80%
Mounting Type Surface Mount Surface Mount
Package / Case 8-SMD Module, 5 Leads 8-SMD Module, 5 Leads
Size / Dimension 0.50" L x 0.32" W x 0.29" H (12.8mm x 8.2mm x 7.3mm) 0.50" L x 0.42" W x 0.28" H (12.8mm x 10.7mm x 7.0mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
MSL 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

The RSS-1512/HP is classified as obsolete. The R1S-1512/HP matches all relevant electrical, mechanical, and compliance parameters and maintains ROHS3 and REACH certifications and EAR99 export classification. The R1S-1512/HP is currently active and available in new original stock and is suitable for immediate substitution based on provided data.

Frequently Asked Questions (FAQ)

Q1: What are the key criteria for substituting RSS-1512/HP?
A1: Key criteria are matching input voltage range, output voltage, output current, power rating, isolation voltage, mounting type, package, application category, operating temperature, efficiency, and compliance certifications.

Q2: Is the package form of R1S-1512/HP suitable for existing RSS-1512/HP designs?
A2: Both models feature a 8-SMD Module, 5 Leads surface mount package with matching mounting type.

Q3: Is there any difference in operating temperature?
A3: R1S-1512/HP supports an extended operating temperature range of -40°C to 100°C compared to -40°C to 85°C for RSS-1512/HP.

Q4: Are both parts compliant with RoHS3 and REACH regulations?
A4: Both RSS-1512/HP and R1S-1512/HP are ROHS3 compliant and REACH unaffected.

Q5: What should engineers consider regarding mechanical fit?
A5: The R1S-1512/HP is very similar in physical dimensions and package format to RSS-1512/HP, supporting direct surface mount replacement within dimensional tolerances provided.

Request Quote (Ships tomorrow)