Recom Power RSS-1215 Equivalent & Substitute Parts Reference

Part Overview

The Recom Power RSS-1215 is an isolated module DC-DC converter in the ECONOLINE RSS (1W) series, featuring single output operation at 15V, 66mA with an input voltage range of 10.8V to 13.2V. This product is currently listed as "Obsolete". As a result, sourcing appropriate substitute models is critical for ongoing designs and field replacements. Substitute selection must strictly adhere to identical electrical and mechanical parameters specified for the RSS-1215.

Substiute Parts

RSS-1215
Recom PowerIn Stock: 1057RSS-1215 Datasheet
RSS-1215
Current Part
R1S-1215
Recom PowerIn Stock: 699R1S-1215 Datasheet
R1S-1215
Direct

Key Parameters

Parameter RSS-1215 Value
Voltage - Input (Min) 10.8V
Voltage - Input (Max) 13.2V
Voltage - Output 1 15V
Current - Output (Max) 66mA
Power (Watts) 1 W
Voltage - Isolation 1 kV
Number of Outputs 1
Mounting Type Surface Mount
Package / Case 8-SMD Module, 5 Leads
Efficiency 82%
Operating Temperature -40°C ~ 85°C
RoHS Status ROHS3 Compliant
REACH Status REACH Unaffected
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

Substitute part grouping is strictly determined by matching the parameters provided for the Recom Power RSS-1215. These include input and output voltages, output current, power rating, isolation voltage, output count, mounting type, package, efficiency, and compliance statuses (RoHS, REACH, MSL). Only parts with identical or higher specification values for all listed parameters are considered suitable substitutes.

Key parameters for substitution:

  • Voltage - Input (Min)
  • Voltage - Input (Max)
  • Voltage - Output (1)
  • Current - Output (Max)
  • Power (Watts)
  • Isolation Voltage
  • Number of Outputs
  • Mounting Type
  • Package / Case
  • Efficiency
  • Operating Temperature
  • RoHS & REACH Status
  • Moisture Sensitivity Level

Parameter Comparison

Parameter RSS-1215 R1S-1215
Voltage - Input (Min) 10.8V 10.8V
Voltage - Input (Max) 13.2V 13.2V
Voltage - Output (1) 15V 15V
Current - Output (Max) 66mA 66mA
Power (Watts) 1 W 1 W
Voltage - Isolation 1 kV 1 kV
Number of Outputs 1 1
Efficiency 82% 82%
Mounting Type Surface Mount Surface Mount
Package / Case 8-SMD Module, 5 Leads 8-SMD Module, 5 Leads
Operating Temperature -40°C ~ 85°C -40°C ~ 100°C
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

Given the RSS-1215 product status is "Obsolete", selection must be based on available substitute components with equivalent compliance and certifications. The substitute R1S-1215 shares all required electrical and mechanical parameters and retains ROHS3 compliance, REACH unaffected status, and MSL 1 (Unlimited), matching the RSS-1215. The substitute is listed as "Active", supporting direct replacement in applications designated for the RSS-1215.

Frequently Asked Questions (FAQ)

Q1: What criteria must substitutes fulfill for the RSS-1215 DC DC Converter?
A1: Substitutes must match the following: input voltage range, output voltage and current, isolation voltage, power rating, mounting type, package, number of outputs, efficiency, compliance status (RoHS, REACH, MSL).

Q2: Are there any compatibility differences in mounting or package between RSS-1215 and R1S-1215?
A2: Both use the surface mount type and the 8-SMD Module, 5 Leads package, ensuring compatibility in PCB layouts.

Q3: How does product status affect selection?
A3: The RSS-1215 is obsolete, requiring designers to select an active, equivalent part such as the R1S-1215.

Q4: Is there any difference in compliance or environmental certifications between the parts?
A4: RSS-1215 and R1S-1215 are both ROHS3 compliant, REACH unaffected, and rated at MSL 1 (Unlimited).

Q5: Can the R1S-1215 be used in all applications previously served by RSS-1215?
A5: R1S-1215 matches all provided parameters including electrical ratings, mechanical footprint, and compliance requirements.

Q6: What should be considered regarding operating temperature?
A6: The R1S-1215 offers a wider operating temperature range; both cover the lower limit and all provided criteria for RSS-1215.

Request Quote (Ships tomorrow)